Line Supply Overvoltage Failure Analysis and Protection Strategy Improvement of Ningbo Rail Transit Line 2 Phase 1 Trains
Aiming at the problem that train traction blocked caused by the line supply overvoltage of Ningbo rail transit line 2 phase 1 train, the cause was analyzed, and with the simulation, an improved solution of overvoltage protection logic according to the system characteristics was proposed, which has b...
| Published in: | 机车电传动 |
|---|---|
| Main Authors: | , |
| Format: | Article |
| Language: | Chinese |
| Published: |
Editorial Department of Electric Drive for Locomotives
2017-01-01
|
| Subjects: | |
| Online Access: | http://edl.csrzic.com/thesisDetails#10.13890/j.issn.1000-128x.2017.06.26 |
| Summary: | Aiming at the problem that train traction blocked caused by the line supply overvoltage of Ningbo rail transit line 2 phase 1 train, the cause was analyzed, and with the simulation, an improved solution of overvoltage protection logic according to the system characteristics was proposed, which has been tested successfully and applied on trains. |
|---|---|
| ISSN: | 1000-128X |