Triangulation Method to Assess Indoor Environmental Conditions and Occupant Comfort and Productivity towards Low Energy Buildings in Malaysia

Saving energy and cutting costs without compromising indoor comfort conditions are challenging, especially in hot and humid regions such as Malaysia. This study explores a new approach to reducing energy consumption without compromising staff comfort in office buildings. This study aims to develop a...

وصف كامل

التفاصيل البيبلوغرافية
الحاوية / القاعدة:Buildings
المؤلفون الرئيسيون: Mohammed Hatim Al-Sabahi, Muhammad Azzam Ismail, Ali Mohammed Alashwal, Karam M. Al-Obaidi
التنسيق: مقال
اللغة:الإنجليزية
منشور في: MDPI AG 2022-10-01
الموضوعات:
الوصول للمادة أونلاين:https://www.mdpi.com/2075-5309/12/11/1788
_version_ 1851845151281905664
author Mohammed Hatim Al-Sabahi
Muhammad Azzam Ismail
Ali Mohammed Alashwal
Karam M. Al-Obaidi
author_facet Mohammed Hatim Al-Sabahi
Muhammad Azzam Ismail
Ali Mohammed Alashwal
Karam M. Al-Obaidi
author_sort Mohammed Hatim Al-Sabahi
collection DOAJ
container_title Buildings
description Saving energy and cutting costs without compromising indoor comfort conditions are challenging, especially in hot and humid regions such as Malaysia. This study explores a new approach to reducing energy consumption without compromising staff comfort in office buildings. This study aims to develop a method for lowering Building Energy Index (BEI) and maintaining acceptable indoor conditions while increasing productivity in office buildings. A developed triangulation method using Building Use Studies (BUS) for evaluating occupant satisfaction, physical measurements, and simulation modelling was implemented to measure indoor performance in an office building. The results indicated that enhancing six variables of building conditions managed to improve occupant satisfaction by 44%. Hence, the productivity of staff in the building increased by 16%. The findings demonstrated that a reduction of 3 h in the operating times of chillers while an increase in chillers’ temperature by 1.5 °C maintained an acceptable indoor environment and reduced the building’s BEI to 89.48 kWh/m<sup>2</sup>/year, with an energy saving of 21.51%, turning the case study into a low energy building.
format Article
id doaj-art-e9858a6dbfef4affb4fe82f772f1d443
institution Directory of Open Access Journals
issn 2075-5309
language English
publishDate 2022-10-01
publisher MDPI AG
record_format Article
spelling doaj-art-e9858a6dbfef4affb4fe82f772f1d4432025-08-19T22:26:35ZengMDPI AGBuildings2075-53092022-10-011211178810.3390/buildings12111788Triangulation Method to Assess Indoor Environmental Conditions and Occupant Comfort and Productivity towards Low Energy Buildings in MalaysiaMohammed Hatim Al-Sabahi0Muhammad Azzam Ismail1Ali Mohammed Alashwal2Karam M. Al-Obaidi3Department of Architecture, Faculty of Built Environment, Universiti Malaya, Kuala Lumpur 50603, MalaysiaDepartment of Architecture, Faculty of Built Environment, Universiti Malaya, Kuala Lumpur 50603, MalaysiaSchool of Engineering, Design and Built Environment, Western Sydney University, Penrith, NSW 2751, AustraliaDepartment of the Natural and Built Environment, College of Social Sciences and Arts, Sheffield Hallam University, Sheffield S1 1WB, UKSaving energy and cutting costs without compromising indoor comfort conditions are challenging, especially in hot and humid regions such as Malaysia. This study explores a new approach to reducing energy consumption without compromising staff comfort in office buildings. This study aims to develop a method for lowering Building Energy Index (BEI) and maintaining acceptable indoor conditions while increasing productivity in office buildings. A developed triangulation method using Building Use Studies (BUS) for evaluating occupant satisfaction, physical measurements, and simulation modelling was implemented to measure indoor performance in an office building. The results indicated that enhancing six variables of building conditions managed to improve occupant satisfaction by 44%. Hence, the productivity of staff in the building increased by 16%. The findings demonstrated that a reduction of 3 h in the operating times of chillers while an increase in chillers’ temperature by 1.5 °C maintained an acceptable indoor environment and reduced the building’s BEI to 89.48 kWh/m<sup>2</sup>/year, with an energy saving of 21.51%, turning the case study into a low energy building.https://www.mdpi.com/2075-5309/12/11/1788triangulation methodindoor comfortindoor environmental conditionsproductivitylow energy buildingtropics
spellingShingle Mohammed Hatim Al-Sabahi
Muhammad Azzam Ismail
Ali Mohammed Alashwal
Karam M. Al-Obaidi
Triangulation Method to Assess Indoor Environmental Conditions and Occupant Comfort and Productivity towards Low Energy Buildings in Malaysia
triangulation method
indoor comfort
indoor environmental conditions
productivity
low energy building
tropics
title Triangulation Method to Assess Indoor Environmental Conditions and Occupant Comfort and Productivity towards Low Energy Buildings in Malaysia
title_full Triangulation Method to Assess Indoor Environmental Conditions and Occupant Comfort and Productivity towards Low Energy Buildings in Malaysia
title_fullStr Triangulation Method to Assess Indoor Environmental Conditions and Occupant Comfort and Productivity towards Low Energy Buildings in Malaysia
title_full_unstemmed Triangulation Method to Assess Indoor Environmental Conditions and Occupant Comfort and Productivity towards Low Energy Buildings in Malaysia
title_short Triangulation Method to Assess Indoor Environmental Conditions and Occupant Comfort and Productivity towards Low Energy Buildings in Malaysia
title_sort triangulation method to assess indoor environmental conditions and occupant comfort and productivity towards low energy buildings in malaysia
topic triangulation method
indoor comfort
indoor environmental conditions
productivity
low energy building
tropics
url https://www.mdpi.com/2075-5309/12/11/1788
work_keys_str_mv AT mohammedhatimalsabahi triangulationmethodtoassessindoorenvironmentalconditionsandoccupantcomfortandproductivitytowardslowenergybuildingsinmalaysia
AT muhammadazzamismail triangulationmethodtoassessindoorenvironmentalconditionsandoccupantcomfortandproductivitytowardslowenergybuildingsinmalaysia
AT alimohammedalashwal triangulationmethodtoassessindoorenvironmentalconditionsandoccupantcomfortandproductivitytowardslowenergybuildingsinmalaysia
AT karammalobaidi triangulationmethodtoassessindoorenvironmentalconditionsandoccupantcomfortandproductivitytowardslowenergybuildingsinmalaysia