Mitigation of Subsynchronous Resonance in Doubly Fed Induction Generator Systems by Static Synchronous Compensator Using Fuzzy Logic

This document focuses on the mitigation of subsynchronous resonance (SSR) in doubly fed induction generators (DFIGs) through the application of an effective solution based on the use of a Static Synchronous Compensator (STATCOM) with fuzzy logic. The STATCOM, a static parallel compensator, improved...

Full description

Bibliographic Details
Published in:Energies
Main Authors: Luis Chicaiza, Luis Tipán, Manuel Jaramillo, Carlos Barrera-Singaña
Format: Article
Language:English
Published: MDPI AG 2025-09-01
Subjects:
Online Access:https://www.mdpi.com/1996-1073/18/17/4653
_version_ 1849267416983404544
author Luis Chicaiza
Luis Tipán
Manuel Jaramillo
Carlos Barrera-Singaña
author_facet Luis Chicaiza
Luis Tipán
Manuel Jaramillo
Carlos Barrera-Singaña
author_sort Luis Chicaiza
collection DOAJ
container_title Energies
description This document focuses on the mitigation of subsynchronous resonance (SSR) in doubly fed induction generators (DFIGs) through the application of an effective solution based on the use of a Static Synchronous Compensator (STATCOM) with fuzzy logic. The STATCOM, a static parallel compensator, improved the stability, quality, and reliability of the power supply in distribution systems by optimizing the response to voltage fluctuations. Combined with fuzzy logic, it provided flexible and efficient control, reducing oscillations arising in the system. Two case studies were carried out in which the DFIG and the STATCOM module with fuzzy logic were implemented in IEEE 13- and IEEE 33-bus systems. Comparative analyses with and without compensation were performed to assess the system’s behavior in response to oscillations generated by the generator, taking voltages as the main variable. The results showed that the fuzzy–PI controlled STATCOM effectively stabilized voltage profiles, mitigating SSR and improving system reliability. In the IEEE 13-bus case, voltage oscillations were reduced by approximately 72% and the bus voltages converged to 0.99–1.01 p.u. within 1.5 s. In the IEEE 33-bus system, the controller achieved a suppression rate of 68%, with voltages restored to 0.98–1.02 p.u. in less than 2 s. These findings demonstrate the efficiency of the proposed fuzzy–PI STATCOM in suppressing subsynchronous oscillations and enhancing stability in DFIG-based networks.
format Article
id doaj-art-ecc9fe2de1a44bed8948ed15342c8a91
institution Directory of Open Access Journals
issn 1996-1073
language English
publishDate 2025-09-01
publisher MDPI AG
record_format Article
spelling doaj-art-ecc9fe2de1a44bed8948ed15342c8a912025-09-12T12:21:05ZengMDPI AGEnergies1996-10732025-09-011817465310.3390/en18174653Mitigation of Subsynchronous Resonance in Doubly Fed Induction Generator Systems by Static Synchronous Compensator Using Fuzzy LogicLuis Chicaiza0Luis Tipán1Manuel Jaramillo2Carlos Barrera-Singaña3Universidad Politécnica Salesiana, Quito 170702, EcuadorElectrical Engineering Department, Universidad Politécnica Salesiana, Quito 170702, EcuadorElectrical Engineering Department, Universidad Politécnica Salesiana, Quito 170702, EcuadorElectrical Engineering Department, Universidad Politécnica Salesiana, Quito 170702, EcuadorThis document focuses on the mitigation of subsynchronous resonance (SSR) in doubly fed induction generators (DFIGs) through the application of an effective solution based on the use of a Static Synchronous Compensator (STATCOM) with fuzzy logic. The STATCOM, a static parallel compensator, improved the stability, quality, and reliability of the power supply in distribution systems by optimizing the response to voltage fluctuations. Combined with fuzzy logic, it provided flexible and efficient control, reducing oscillations arising in the system. Two case studies were carried out in which the DFIG and the STATCOM module with fuzzy logic were implemented in IEEE 13- and IEEE 33-bus systems. Comparative analyses with and without compensation were performed to assess the system’s behavior in response to oscillations generated by the generator, taking voltages as the main variable. The results showed that the fuzzy–PI controlled STATCOM effectively stabilized voltage profiles, mitigating SSR and improving system reliability. In the IEEE 13-bus case, voltage oscillations were reduced by approximately 72% and the bus voltages converged to 0.99–1.01 p.u. within 1.5 s. In the IEEE 33-bus system, the controller achieved a suppression rate of 68%, with voltages restored to 0.98–1.02 p.u. in less than 2 s. These findings demonstrate the efficiency of the proposed fuzzy–PI STATCOM in suppressing subsynchronous oscillations and enhancing stability in DFIG-based networks.https://www.mdpi.com/1996-1073/18/17/4653fuzzy logic controlstatic synchronous compensators (STATCOM)subsynchronous resonance
spellingShingle Luis Chicaiza
Luis Tipán
Manuel Jaramillo
Carlos Barrera-Singaña
Mitigation of Subsynchronous Resonance in Doubly Fed Induction Generator Systems by Static Synchronous Compensator Using Fuzzy Logic
fuzzy logic control
static synchronous compensators (STATCOM)
subsynchronous resonance
title Mitigation of Subsynchronous Resonance in Doubly Fed Induction Generator Systems by Static Synchronous Compensator Using Fuzzy Logic
title_full Mitigation of Subsynchronous Resonance in Doubly Fed Induction Generator Systems by Static Synchronous Compensator Using Fuzzy Logic
title_fullStr Mitigation of Subsynchronous Resonance in Doubly Fed Induction Generator Systems by Static Synchronous Compensator Using Fuzzy Logic
title_full_unstemmed Mitigation of Subsynchronous Resonance in Doubly Fed Induction Generator Systems by Static Synchronous Compensator Using Fuzzy Logic
title_short Mitigation of Subsynchronous Resonance in Doubly Fed Induction Generator Systems by Static Synchronous Compensator Using Fuzzy Logic
title_sort mitigation of subsynchronous resonance in doubly fed induction generator systems by static synchronous compensator using fuzzy logic
topic fuzzy logic control
static synchronous compensators (STATCOM)
subsynchronous resonance
url https://www.mdpi.com/1996-1073/18/17/4653
work_keys_str_mv AT luischicaiza mitigationofsubsynchronousresonanceindoublyfedinductiongeneratorsystemsbystaticsynchronouscompensatorusingfuzzylogic
AT luistipan mitigationofsubsynchronousresonanceindoublyfedinductiongeneratorsystemsbystaticsynchronouscompensatorusingfuzzylogic
AT manueljaramillo mitigationofsubsynchronousresonanceindoublyfedinductiongeneratorsystemsbystaticsynchronouscompensatorusingfuzzylogic
AT carlosbarrerasingana mitigationofsubsynchronousresonanceindoublyfedinductiongeneratorsystemsbystaticsynchronouscompensatorusingfuzzylogic