Field evaluation of the performance of seven Antigen Rapid diagnostic tests for the diagnosis of SARs-CoV-2 virus infection in Uganda

<h4>Objective</h4> The objective of this study was to evaluate the performance of seven antigen rapid diagnostic tests (Ag RDTs) in a clinical setting to identify those that could be recommended for use in the diagnosis of SARS-CoV-2 infection in Uganda. <h4>Methods</h4> This...

Full description

Bibliographic Details
Published in:PLoS ONE
Main Authors: Josephine Bwogi, Tom Lutalo, Phionah Tushabe, Henry Bukenya, James Peter Eliku, Isaac Ssewanyana, Susan Nabadda, Christopher Nsereko, Matthew Cotten, Robert Downing, Julius Lutwama, Pontiano Kaleebu, EPI Laboratory team, UVRI -COVID 19 Technical team
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2022-01-01
Online Access:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9089886/?tool=EBI
Description
Summary:<h4>Objective</h4> The objective of this study was to evaluate the performance of seven antigen rapid diagnostic tests (Ag RDTs) in a clinical setting to identify those that could be recommended for use in the diagnosis of SARS-CoV-2 infection in Uganda. <h4>Methods</h4> This was a cross-sectional prospective study. Nasopharyngeal swabs were collected consecutively from COVID-19 PCR positive and COVID-19 PCR negative participants at isolation centers and points of entry, and tested with the SARS-CoV-2 Ag RDTs. Test sensitivity and specificity were generated by comparing results against qRT-PCR results (Berlin Protocol) at a cycle threshold (Ct) cut-off of ≤39. Sensitivity was also calculated at Ct cut-offs ≤29 and ≤33. <h4>Results</h4> None of the Ag RDTs had a sensitivity of ≥80% at Ct cut-off values ≤33 and ≤39. Two kits, Panbio™ COVID-19 Ag and VivaDiag™ SARS-CoV-2 Ag had a sensitivity of ≥80% at a Ct cut-off value of ≤29. Four kits: BIOCREDIT COVID -19 Ag, COVID-19 Ag Respi-Strip, MEDsan® SARS-CoV-2 Antigen Rapid Test and Panbio™ COVID-19 Ag Rapid Test had a specificity of ≥97%. <h4>Conclusions</h4> This evaluation identified one Ag RDT, Panbio™ COVID-19 Ag with a performance at high viral load (Ct value ≤29) reaching that recommended by WHO. This kit was recommended for screening of patients with COVID -19-like symptoms presenting at health facilities.
ISSN:1932-6203