Field evaluation of the performance of seven Antigen Rapid diagnostic tests for the diagnosis of SARs-CoV-2 virus infection in Uganda
<h4>Objective</h4> The objective of this study was to evaluate the performance of seven antigen rapid diagnostic tests (Ag RDTs) in a clinical setting to identify those that could be recommended for use in the diagnosis of SARS-CoV-2 infection in Uganda. <h4>Methods</h4> This...
| Published in: | PLoS ONE |
|---|---|
| Main Authors: | , , , , , , , , , , , , , |
| Format: | Article |
| Language: | English |
| Published: |
Public Library of Science (PLoS)
2022-01-01
|
| Online Access: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9089886/?tool=EBI |
| _version_ | 1857050719019859968 |
|---|---|
| author | Josephine Bwogi Tom Lutalo Phionah Tushabe Henry Bukenya James Peter Eliku Isaac Ssewanyana Susan Nabadda Christopher Nsereko Matthew Cotten Robert Downing Julius Lutwama Pontiano Kaleebu EPI Laboratory team UVRI -COVID 19 Technical team |
| author_facet | Josephine Bwogi Tom Lutalo Phionah Tushabe Henry Bukenya James Peter Eliku Isaac Ssewanyana Susan Nabadda Christopher Nsereko Matthew Cotten Robert Downing Julius Lutwama Pontiano Kaleebu EPI Laboratory team UVRI -COVID 19 Technical team |
| author_sort | Josephine Bwogi |
| collection | DOAJ |
| container_title | PLoS ONE |
| description | <h4>Objective</h4> The objective of this study was to evaluate the performance of seven antigen rapid diagnostic tests (Ag RDTs) in a clinical setting to identify those that could be recommended for use in the diagnosis of SARS-CoV-2 infection in Uganda. <h4>Methods</h4> This was a cross-sectional prospective study. Nasopharyngeal swabs were collected consecutively from COVID-19 PCR positive and COVID-19 PCR negative participants at isolation centers and points of entry, and tested with the SARS-CoV-2 Ag RDTs. Test sensitivity and specificity were generated by comparing results against qRT-PCR results (Berlin Protocol) at a cycle threshold (Ct) cut-off of ≤39. Sensitivity was also calculated at Ct cut-offs ≤29 and ≤33. <h4>Results</h4> None of the Ag RDTs had a sensitivity of ≥80% at Ct cut-off values ≤33 and ≤39. Two kits, Panbio™ COVID-19 Ag and VivaDiag™ SARS-CoV-2 Ag had a sensitivity of ≥80% at a Ct cut-off value of ≤29. Four kits: BIOCREDIT COVID -19 Ag, COVID-19 Ag Respi-Strip, MEDsan® SARS-CoV-2 Antigen Rapid Test and Panbio™ COVID-19 Ag Rapid Test had a specificity of ≥97%. <h4>Conclusions</h4> This evaluation identified one Ag RDT, Panbio™ COVID-19 Ag with a performance at high viral load (Ct value ≤29) reaching that recommended by WHO. This kit was recommended for screening of patients with COVID -19-like symptoms presenting at health facilities. |
| format | Article |
| id | doaj-art-ece18cd3159e4e23a313fdf1343211a5 |
| institution | Directory of Open Access Journals |
| issn | 1932-6203 |
| language | English |
| publishDate | 2022-01-01 |
| publisher | Public Library of Science (PLoS) |
| record_format | Article |
| spelling | doaj-art-ece18cd3159e4e23a313fdf1343211a52025-08-19T19:33:04ZengPublic Library of Science (PLoS)PLoS ONE1932-62032022-01-01175Field evaluation of the performance of seven Antigen Rapid diagnostic tests for the diagnosis of SARs-CoV-2 virus infection in UgandaJosephine BwogiTom LutaloPhionah TushabeHenry BukenyaJames Peter ElikuIsaac SsewanyanaSusan NabaddaChristopher NserekoMatthew CottenRobert DowningJulius LutwamaPontiano KaleebuEPI Laboratory teamUVRI -COVID 19 Technical team<h4>Objective</h4> The objective of this study was to evaluate the performance of seven antigen rapid diagnostic tests (Ag RDTs) in a clinical setting to identify those that could be recommended for use in the diagnosis of SARS-CoV-2 infection in Uganda. <h4>Methods</h4> This was a cross-sectional prospective study. Nasopharyngeal swabs were collected consecutively from COVID-19 PCR positive and COVID-19 PCR negative participants at isolation centers and points of entry, and tested with the SARS-CoV-2 Ag RDTs. Test sensitivity and specificity were generated by comparing results against qRT-PCR results (Berlin Protocol) at a cycle threshold (Ct) cut-off of ≤39. Sensitivity was also calculated at Ct cut-offs ≤29 and ≤33. <h4>Results</h4> None of the Ag RDTs had a sensitivity of ≥80% at Ct cut-off values ≤33 and ≤39. Two kits, Panbio™ COVID-19 Ag and VivaDiag™ SARS-CoV-2 Ag had a sensitivity of ≥80% at a Ct cut-off value of ≤29. Four kits: BIOCREDIT COVID -19 Ag, COVID-19 Ag Respi-Strip, MEDsan® SARS-CoV-2 Antigen Rapid Test and Panbio™ COVID-19 Ag Rapid Test had a specificity of ≥97%. <h4>Conclusions</h4> This evaluation identified one Ag RDT, Panbio™ COVID-19 Ag with a performance at high viral load (Ct value ≤29) reaching that recommended by WHO. This kit was recommended for screening of patients with COVID -19-like symptoms presenting at health facilities.https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9089886/?tool=EBI |
| spellingShingle | Josephine Bwogi Tom Lutalo Phionah Tushabe Henry Bukenya James Peter Eliku Isaac Ssewanyana Susan Nabadda Christopher Nsereko Matthew Cotten Robert Downing Julius Lutwama Pontiano Kaleebu EPI Laboratory team UVRI -COVID 19 Technical team Field evaluation of the performance of seven Antigen Rapid diagnostic tests for the diagnosis of SARs-CoV-2 virus infection in Uganda |
| title | Field evaluation of the performance of seven Antigen Rapid diagnostic tests for the diagnosis of SARs-CoV-2 virus infection in Uganda |
| title_full | Field evaluation of the performance of seven Antigen Rapid diagnostic tests for the diagnosis of SARs-CoV-2 virus infection in Uganda |
| title_fullStr | Field evaluation of the performance of seven Antigen Rapid diagnostic tests for the diagnosis of SARs-CoV-2 virus infection in Uganda |
| title_full_unstemmed | Field evaluation of the performance of seven Antigen Rapid diagnostic tests for the diagnosis of SARs-CoV-2 virus infection in Uganda |
| title_short | Field evaluation of the performance of seven Antigen Rapid diagnostic tests for the diagnosis of SARs-CoV-2 virus infection in Uganda |
| title_sort | field evaluation of the performance of seven antigen rapid diagnostic tests for the diagnosis of sars cov 2 virus infection in uganda |
| url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9089886/?tool=EBI |
| work_keys_str_mv | AT josephinebwogi fieldevaluationoftheperformanceofsevenantigenrapiddiagnostictestsforthediagnosisofsarscov2virusinfectioninuganda AT tomlutalo fieldevaluationoftheperformanceofsevenantigenrapiddiagnostictestsforthediagnosisofsarscov2virusinfectioninuganda AT phionahtushabe fieldevaluationoftheperformanceofsevenantigenrapiddiagnostictestsforthediagnosisofsarscov2virusinfectioninuganda AT henrybukenya fieldevaluationoftheperformanceofsevenantigenrapiddiagnostictestsforthediagnosisofsarscov2virusinfectioninuganda AT jamespetereliku fieldevaluationoftheperformanceofsevenantigenrapiddiagnostictestsforthediagnosisofsarscov2virusinfectioninuganda AT isaacssewanyana fieldevaluationoftheperformanceofsevenantigenrapiddiagnostictestsforthediagnosisofsarscov2virusinfectioninuganda AT susannabadda fieldevaluationoftheperformanceofsevenantigenrapiddiagnostictestsforthediagnosisofsarscov2virusinfectioninuganda AT christophernsereko fieldevaluationoftheperformanceofsevenantigenrapiddiagnostictestsforthediagnosisofsarscov2virusinfectioninuganda AT matthewcotten fieldevaluationoftheperformanceofsevenantigenrapiddiagnostictestsforthediagnosisofsarscov2virusinfectioninuganda AT robertdowning fieldevaluationoftheperformanceofsevenantigenrapiddiagnostictestsforthediagnosisofsarscov2virusinfectioninuganda AT juliuslutwama fieldevaluationoftheperformanceofsevenantigenrapiddiagnostictestsforthediagnosisofsarscov2virusinfectioninuganda AT pontianokaleebu fieldevaluationoftheperformanceofsevenantigenrapiddiagnostictestsforthediagnosisofsarscov2virusinfectioninuganda AT epilaboratoryteam fieldevaluationoftheperformanceofsevenantigenrapiddiagnostictestsforthediagnosisofsarscov2virusinfectioninuganda AT uvricovid19technicalteam fieldevaluationoftheperformanceofsevenantigenrapiddiagnostictestsforthediagnosisofsarscov2virusinfectioninuganda |
