Scattergram patterns of hematological malignancies on sysmex XN-series analyzer
BACKGROUND: Automated hematology analyzers effectively reduce turnaround time and generates scattergrams which can be used to screen for different hematological conditions. AIMS: We wish to study the scattergrams generated by the Sysmex XN-series analyzer for confirmed cases of hematological maligna...
| Published in: | Journal of Applied Hematology |
|---|---|
| Main Authors: | Aparna Ningombam, Shreyam Acharya, Abhirup Sarkar, Kundan Kumar, Anita Chopra |
| Format: | Article |
| Language: | English |
| Published: |
Wolters Kluwer Medknow Publications
2021-01-01
|
| Subjects: | |
| Online Access: | http://www.jahjournal.org/article.asp?issn=1658-5127;year=2021;volume=12;issue=2;spage=83;epage=89;aulast=Ningombam |
Similar Items
AUTOMATED HEMATOLOGY ANALYZERS IN DIAGNOSIS OF PLASMODIUM VIVAX MALARIA: AN ADJUNCT TO CONVENTIONAL MICROSCOPY.
by: Kolakkadan Mubeen Hasaf, et al.
Published: (2014-05-01)
by: Kolakkadan Mubeen Hasaf, et al.
Published: (2014-05-01)
Evaluation of sensitivity and specificity of high fluorescence lymphocyte count percentage of sysmex XN analyzer in diagnosis of dengue
by: Aparna Ningombam, et al.
Published: (2022-01-01)
by: Aparna Ningombam, et al.
Published: (2022-01-01)
Scatter gram patterns of hematological malignancies in Sysmex XN series
by: Kovuri Umadevi, et al.
Published: (2023-07-01)
by: Kovuri Umadevi, et al.
Published: (2023-07-01)
Comparison of results of two hematological analyzer systems: Dirui BF-7200 and Sysmex XN-1000
by: Seyithanoğlu Muhammed, et al.
Published: (2023-11-01)
by: Seyithanoğlu Muhammed, et al.
Published: (2023-11-01)
Possibilities and limitations of digital microscopy of blood smear of the modern hematological analyser Sysmex XN-3100 in leukocyte differentiation
by: Klapuh-Bukvić Nermina, et al.
Published: (2025-01-01)
by: Klapuh-Bukvić Nermina, et al.
Published: (2025-01-01)
Evaluating the research parameters available on the Sysmex® XN-series hematology analyzers as markers of dysplasia in peripheral blood
by: Aguadero Vicente, et al.
Published: (2025-02-01)
by: Aguadero Vicente, et al.
Published: (2025-02-01)
Comparative Analysis of Erythrocyte, Leukocyte, and Platelet Indices through Examinations using Sysmex XN-3000 and Yumizen H2500 in Clinical Practice
by: Yuniar Putri Wardani, et al.
Published: (2025-01-01)
by: Yuniar Putri Wardani, et al.
Published: (2025-01-01)
Determination of reference intervals of hemogram with advanced clinical parameters by indirect method on Sysmex XN-1000
by: Bildirici Mehmet Akif, et al.
Published: (2023-06-01)
by: Bildirici Mehmet Akif, et al.
Published: (2023-06-01)
Performance of Platelet Counting in Thrombocytopenic Samples: Comparison between Mindray BC-6800Plus and Sysmex XN-9000
by: Hanah Kim, et al.
Published: (2021-12-01)
by: Hanah Kim, et al.
Published: (2021-12-01)
Evaluation of the New Beckmann Coulter Analyzer DxH 900 Compared to Sysmex XN20: Analytical Performance and Flagging Efficiency
by: Maite Serrando Querol, et al.
Published: (2021-09-01)
by: Maite Serrando Querol, et al.
Published: (2021-09-01)
Optimizing urinary tract infection diagnosis: time and resource efficiency with the Sysmex UF-4000i
by: Babacar Ndiaye, et al.
Published: (2025-04-01)
by: Babacar Ndiaye, et al.
Published: (2025-04-01)
Diagnostic accuracy of fluorescence flow-cytometry technology using Sysmex XN-31 for imported malaria in a non-endemic setting
by: Picot Stéphane, et al.
Published: (2022-01-01)
by: Picot Stéphane, et al.
Published: (2022-01-01)
Pseudomonocytosis on a Sysmex XN haematology analyser masking the monocytopenia of hairy cell leukaemia in a South African woman
by: Stephanie J. Kennedy, et al.
Published: (2025-03-01)
by: Stephanie J. Kennedy, et al.
Published: (2025-03-01)
Investigation of morphological changes for the discrimination of nucleated red blood cells and other leukocytes in Sysmex XN hematology analyzer scattergrams using transmission electron microscopy
by: Masako Kaido, et al.
Published: (2017-08-01)
by: Masako Kaido, et al.
Published: (2017-08-01)
Canine Cerebrospinal Fluid Analysis Using Two New Automated Techniques: The Sysmex XN-V Body Fluid Mode and an Artificial-Intelligence-Based Algorithm
by: Sandra Lapsina, et al.
Published: (2024-05-01)
by: Sandra Lapsina, et al.
Published: (2024-05-01)
Rapid Detection of <i>Plasmodium vivax</i> by the Hematology Analyzer for Population Screening
by: Shanaz Khodaiji, et al.
Published: (2023-11-01)
by: Shanaz Khodaiji, et al.
Published: (2023-11-01)
Performance evaluation of the automated body fluid analysis of the new Sysmex XR haematology analyser
by: Van Laer Christine, et al.
Published: (2023-12-01)
by: Van Laer Christine, et al.
Published: (2023-12-01)
HemoScreen hematology analyzer compared to Sysmex XN for complete blood count, white blood cell differential, and detection of leukocyte abnormalities
by: Anna‐Maria Linko‐Parvinen, et al.
Published: (2022-11-01)
by: Anna‐Maria Linko‐Parvinen, et al.
Published: (2022-11-01)
Performance Assessment of Sysmex® CA-104 for Screening Coagulogram Testing
by: Oranut Komkhum, et al.
Published: (2016-01-01)
by: Oranut Komkhum, et al.
Published: (2016-01-01)
Comparison of Sysmex XN-V body fluid mode and deep-learning-based quantification with manual techniques for total nucleated cell count and differential count for equine bronchoalveolar lavage samples
by: Sandra Lapsina, et al.
Published: (2024-02-01)
by: Sandra Lapsina, et al.
Published: (2024-02-01)
Candiduria in hospitalized patients: an investigation with the Sysmex UF-1000i urine analyzer
by: Zhengxin He, et al.
Published: (2019-05-01)
by: Zhengxin He, et al.
Published: (2019-05-01)
Red cell histograms and spurious parameters in anemia – Study of diagnostic utility of autoanalyzer results
by: Saricha Agarwal, et al.
Published: (2024-01-01)
by: Saricha Agarwal, et al.
Published: (2024-01-01)
A Pilot Study of Circulating Monocyte Subsets in Patients Treated with Stem Cell Transplantation for High-Risk Hematological Malignancies
by: Ida Marie Rundgren, et al.
Published: (2020-01-01)
by: Ida Marie Rundgren, et al.
Published: (2020-01-01)
Complete blood count in neonatal Intensive care Unit (NICU): Performance comparison between POCT Sight OLO® and Sysmex XN-9100™ hematology analyzers
by: Francesca Nencini, et al.
Published: (2025-04-01)
by: Francesca Nencini, et al.
Published: (2025-04-01)
Valoración de los parámetros de investigación de los analizadores hematológicos de la serie XN (Sysmex®) como marcadores de displasia en sangre perifèrica
by: Aguadero Vicente, et al.
Published: (2024-12-01)
by: Aguadero Vicente, et al.
Published: (2024-12-01)
Nutrient analysis in estuarine water. Effect of salinity
by: M Arjonilla, et al.
Published: (2003-03-01)
by: M Arjonilla, et al.
Published: (2003-03-01)
Influence of Plasma Interferences on Screening Coagulogram and Performance Evaluation of the Automated Coagulation Analyzer Sysmex® CS-2100i
by: Chaicharoen Tantanate, et al.
Published: (2020-04-01)
by: Chaicharoen Tantanate, et al.
Published: (2020-04-01)
Comparison of SYSMEX CN-6000 and STAGO STA-R: Effects of hemolysis and lipemia
by: Orhan Seren, et al.
Published: (2025-01-01)
by: Orhan Seren, et al.
Published: (2025-01-01)
Selection of Unnecessary Urine Culture Specimens Using
Sysmex UF-5000 Urine Flow Cytometer
by: Duyeal Song, et al.
Published: (2018-12-01)
by: Duyeal Song, et al.
Published: (2018-12-01)
How Reproducible Is the Data from Sysmex DI-60 in Leukopenic Samples?
by: Sumi Yoon, et al.
Published: (2021-11-01)
by: Sumi Yoon, et al.
Published: (2021-11-01)
Hematology instruments don’t speak the same language: a comparison study between flagging messages of sysmex XN-1000 and alinity H
by: Oprea Oana Roxana, et al.
Published: (2025-04-01)
by: Oprea Oana Roxana, et al.
Published: (2025-04-01)
Utility of immature platelet fraction in the Sysmex XN‐1000V for the differential diagnosis of central and peripheral thrombocytopenia in dogs and cats
by: Alejandro Perez‐Ecija, et al.
Published: (2024-05-01)
by: Alejandro Perez‐Ecija, et al.
Published: (2024-05-01)
The Utility of Automated Haematology Analyser Scattergrams in the Diagnosis of Malaria
by: Keerthi Ramachandran Pillai, et al.
Published: (2020-01-01)
by: Keerthi Ramachandran Pillai, et al.
Published: (2020-01-01)
High-Sensitivity Flow Cytometry for the Reliable Detection of Measurable Residual Disease in Hematological Malignancies in Clinical Laboratories
by: María Beatriz Álvarez Flores, et al.
Published: (2024-12-01)
by: María Beatriz Álvarez Flores, et al.
Published: (2024-12-01)
Performance evaluation of the digital morphology analyser Sysmex DI-60 for white blood cell differentials in abnormal samples
by: Yan Zhao, et al.
Published: (2024-06-01)
by: Yan Zhao, et al.
Published: (2024-06-01)
Characterization of Feline Basophils on the Sysmex XN-1000V and Evaluation of a New WDF Gating Profile
by: Javier Martínez-Caro, et al.
Published: (2024-11-01)
by: Javier Martínez-Caro, et al.
Published: (2024-11-01)
Endothelial cells in the peripheral blood smear: An incidental finding
by: Shreyam Acharya, et al.
Published: (2021-01-01)
by: Shreyam Acharya, et al.
Published: (2021-01-01)
Using RET-He and Delta-He in the Sysmex XN-1000V Analyzer to Differentiate Between Chronic Hemorrhagic and Chronic Inflammatory Anemia in Small Animals
by: Alejandro Perez-Ecija, et al.
Published: (2024-11-01)
by: Alejandro Perez-Ecija, et al.
Published: (2024-11-01)
The Immature Reticulocyte Fraction (IRF) in the Sysmex XN-1000V Analyzer Can Differentiate between Causes of Regenerative and Non-Regenerative Anemia in Dogs and Cats
by: Alejandro Perez-Ecija, et al.
Published: (2024-01-01)
by: Alejandro Perez-Ecija, et al.
Published: (2024-01-01)
Neutrophil granulocytes from Sysmex XN – are the results reliable when the “Blasts/Abn Lympho?” flag is reported?
by: Heidi Eilertsen, et al.
Published: (2025-09-01)
by: Heidi Eilertsen, et al.
Published: (2025-09-01)
Similar Items
-
AUTOMATED HEMATOLOGY ANALYZERS IN DIAGNOSIS OF PLASMODIUM VIVAX MALARIA: AN ADJUNCT TO CONVENTIONAL MICROSCOPY.
by: Kolakkadan Mubeen Hasaf, et al.
Published: (2014-05-01) -
Evaluation of sensitivity and specificity of high fluorescence lymphocyte count percentage of sysmex XN analyzer in diagnosis of dengue
by: Aparna Ningombam, et al.
Published: (2022-01-01) -
Scatter gram patterns of hematological malignancies in Sysmex XN series
by: Kovuri Umadevi, et al.
Published: (2023-07-01) -
Comparison of results of two hematological analyzer systems: Dirui BF-7200 and Sysmex XN-1000
by: Seyithanoğlu Muhammed, et al.
Published: (2023-11-01) -
Possibilities and limitations of digital microscopy of blood smear of the modern hematological analyser Sysmex XN-3100 in leukocyte differentiation
by: Klapuh-Bukvić Nermina, et al.
Published: (2025-01-01)
