Feasibility Study of Wind Farm Grid-Connected Project in Algeria under Grid Fault Conditions Using D-Facts Devices
The use of renewable energy such as wind power is one of the most affordable solutions to meet the basic demand for electricity because it is the cleanest and most efficient resource. In Algeria, the highland region has considerable wind potential. However, the electrical power system located is thi...
| Published in: | Applied Sciences |
|---|---|
| Main Authors: | , , , , , |
| Format: | Article |
| Language: | English |
| Published: |
MDPI AG
2018-11-01
|
| Subjects: | |
| Online Access: | https://www.mdpi.com/2076-3417/8/11/2250 |
| _version_ | 1856908118491922432 |
|---|---|
| author | Lina Wang Kamel Djamel Eddine Kerrouche Abdelkader Mezouar Alex Van Den Bossche Azzedine Draou Larbi Boumediene |
| author_facet | Lina Wang Kamel Djamel Eddine Kerrouche Abdelkader Mezouar Alex Van Den Bossche Azzedine Draou Larbi Boumediene |
| author_sort | Lina Wang |
| collection | DOAJ |
| container_title | Applied Sciences |
| description | The use of renewable energy such as wind power is one of the most affordable solutions to meet the basic demand for electricity because it is the cleanest and most efficient resource. In Algeria, the highland region has considerable wind potential. However, the electrical power system located is this region is generally not powerful enough to solve the problems of voltage instability during grid fault conditions. These problems can make the connection with the eventual installation of a wind farm very difficult and inefficient. Therefore, a wind farm project in this region may require dynamic compensation devices, such as a distributed-flexible AC transmission system (D-FACTS) to improve its fault ride through (FRT) capability. This paper investigates the implementation of shunt D-FACTS, under grid fault conditions, considering the grid requirements over FRT performance and the voltage stability issue for a wind farm connected to the distribution network in the Algerian highland region. Two types of D-FACTSs considered in this paper are the distribution static VAr compensator (D-SVC) and the distribution static synchronous compensator (D-STATCOM). Some simulation results show a comparative study between the D-SVC and D-STATCOM devices connected at the point of common coupling (PCC) to support a wind farm based on a doubly fed induction generator (DFIG) under grid fault conditions. Finally, an appropriate solution to this problem is presented by sizing and giving the suitable choice of D-FACTS, while offering a feasibility study of this wind farm project by economic analysis. |
| format | Article |
| id | doaj-art-fac94de7f6344ab28d27c76ca258c278 |
| institution | Directory of Open Access Journals |
| issn | 2076-3417 |
| language | English |
| publishDate | 2018-11-01 |
| publisher | MDPI AG |
| record_format | Article |
| spelling | doaj-art-fac94de7f6344ab28d27c76ca258c2782025-08-19T20:21:39ZengMDPI AGApplied Sciences2076-34172018-11-01811225010.3390/app8112250app8112250Feasibility Study of Wind Farm Grid-Connected Project in Algeria under Grid Fault Conditions Using D-Facts DevicesLina Wang0Kamel Djamel Eddine Kerrouche1Abdelkader Mezouar2Alex Van Den Bossche3Azzedine Draou4Larbi Boumediene5School of Automation on Science and Electrical Engineering, Beihang University, Beijing 100191, ChinaSchool of Automation on Science and Electrical Engineering, Beihang University, Beijing 100191, ChinaElectro-Technical Engineering Lab, Faculty of Technology, Tahar Moulay University, Saida 20 000, AlgeriaElectrical Energy LAB EELAB Sint–Pietersnieuwstraat 41, B 9000 Ghent, BelgiumDepartment of Electrical Engineering, Madinah Mounawara University, Madinah 20012, Saudi ArabiaElectro-Technical Engineering Lab, Faculty of Technology, Tahar Moulay University, Saida 20 000, AlgeriaThe use of renewable energy such as wind power is one of the most affordable solutions to meet the basic demand for electricity because it is the cleanest and most efficient resource. In Algeria, the highland region has considerable wind potential. However, the electrical power system located is this region is generally not powerful enough to solve the problems of voltage instability during grid fault conditions. These problems can make the connection with the eventual installation of a wind farm very difficult and inefficient. Therefore, a wind farm project in this region may require dynamic compensation devices, such as a distributed-flexible AC transmission system (D-FACTS) to improve its fault ride through (FRT) capability. This paper investigates the implementation of shunt D-FACTS, under grid fault conditions, considering the grid requirements over FRT performance and the voltage stability issue for a wind farm connected to the distribution network in the Algerian highland region. Two types of D-FACTSs considered in this paper are the distribution static VAr compensator (D-SVC) and the distribution static synchronous compensator (D-STATCOM). Some simulation results show a comparative study between the D-SVC and D-STATCOM devices connected at the point of common coupling (PCC) to support a wind farm based on a doubly fed induction generator (DFIG) under grid fault conditions. Finally, an appropriate solution to this problem is presented by sizing and giving the suitable choice of D-FACTS, while offering a feasibility study of this wind farm project by economic analysis.https://www.mdpi.com/2076-3417/8/11/2250wind farmFault Ride Through (FRT)Distributed-Flexible AC Transmission system (D-FACTS)Distribution Static VAr Compensator(D-SVC)Distribution Static Synchronous Compensator (D-STATCOM) |
| spellingShingle | Lina Wang Kamel Djamel Eddine Kerrouche Abdelkader Mezouar Alex Van Den Bossche Azzedine Draou Larbi Boumediene Feasibility Study of Wind Farm Grid-Connected Project in Algeria under Grid Fault Conditions Using D-Facts Devices wind farm Fault Ride Through (FRT) Distributed-Flexible AC Transmission system (D-FACTS) Distribution Static VAr Compensator(D-SVC) Distribution Static Synchronous Compensator (D-STATCOM) |
| title | Feasibility Study of Wind Farm Grid-Connected Project in Algeria under Grid Fault Conditions Using D-Facts Devices |
| title_full | Feasibility Study of Wind Farm Grid-Connected Project in Algeria under Grid Fault Conditions Using D-Facts Devices |
| title_fullStr | Feasibility Study of Wind Farm Grid-Connected Project in Algeria under Grid Fault Conditions Using D-Facts Devices |
| title_full_unstemmed | Feasibility Study of Wind Farm Grid-Connected Project in Algeria under Grid Fault Conditions Using D-Facts Devices |
| title_short | Feasibility Study of Wind Farm Grid-Connected Project in Algeria under Grid Fault Conditions Using D-Facts Devices |
| title_sort | feasibility study of wind farm grid connected project in algeria under grid fault conditions using d facts devices |
| topic | wind farm Fault Ride Through (FRT) Distributed-Flexible AC Transmission system (D-FACTS) Distribution Static VAr Compensator(D-SVC) Distribution Static Synchronous Compensator (D-STATCOM) |
| url | https://www.mdpi.com/2076-3417/8/11/2250 |
| work_keys_str_mv | AT linawang feasibilitystudyofwindfarmgridconnectedprojectinalgeriaundergridfaultconditionsusingdfactsdevices AT kameldjameleddinekerrouche feasibilitystudyofwindfarmgridconnectedprojectinalgeriaundergridfaultconditionsusingdfactsdevices AT abdelkadermezouar feasibilitystudyofwindfarmgridconnectedprojectinalgeriaundergridfaultconditionsusingdfactsdevices AT alexvandenbossche feasibilitystudyofwindfarmgridconnectedprojectinalgeriaundergridfaultconditionsusingdfactsdevices AT azzedinedraou feasibilitystudyofwindfarmgridconnectedprojectinalgeriaundergridfaultconditionsusingdfactsdevices AT larbiboumediene feasibilitystudyofwindfarmgridconnectedprojectinalgeriaundergridfaultconditionsusingdfactsdevices |