A randomized controlled study to compare oropharyngeal leak pressure between I-gel™ and laryngeal mask airway supreme™ in children in lateral position under general anesthesia
Abstract Background Supraglottic airway devices (SADs) are the mainstay for airway management in pediatric ambulatory surgeries and may often be a suitable alternative to endotracheal intubation due to their favorable profile. Optimal oropharyngeal leak pressure of SAD is essential for adequate vent...
| 發表在: | Ain Shams Journal of Anesthesiology |
|---|---|
| Main Authors: | , , , , |
| 格式: | Article |
| 語言: | 英语 |
| 出版: |
https://asja.journals.ekb.eg/
2023-03-01
|
| 主題: | |
| 在線閱讀: | https://doi.org/10.1186/s42077-023-00315-9 |
| _version_ | 1848652054594060288 |
|---|---|
| author | Raksha Kundal Kriti Puri Garima Agrawal Ranju Singh Maitree Pandey |
| author_facet | Raksha Kundal Kriti Puri Garima Agrawal Ranju Singh Maitree Pandey |
| author_sort | Raksha Kundal |
| collection | DOAJ |
| container_title | Ain Shams Journal of Anesthesiology |
| description | Abstract Background Supraglottic airway devices (SADs) are the mainstay for airway management in pediatric ambulatory surgeries and may often be a suitable alternative to endotracheal intubation due to their favorable profile. Optimal oropharyngeal leak pressure of SAD is essential for adequate ventilation and prevention of aspiration. Occasionally, lateral position is required for administration of regional block or for the surgery itself. We aim to compare the oropharyngeal leak pressure of igel™ and LMA Supreme™ in children in lateral position. A prospective, randomized study was performed on eighty children of either sex, weighing 5–10 kg, belonging to ASA grade I and II undergoing elective surgery requiring lateral position. The primary objective was comparison of Oropharyngeal leak pressure of both devices in lateral position. Secondary objectives included assessment of insertion success rate, number of insertion attempts and manipulations, time and ease of insertion; and comparison of fiberoptic view of the larynx, fractional volume loss, and displacement with respect to both devices in supine and lateral position. Results Oropharyngeal leak pressure of i-gel™ was higher than that of LMA Supreme™ in both supine (25.4 ± 1.4 cm H2O Vs 22.9 ± 1.5 cm H2O) and lateral position (23.9 ± 1.6 vs 21.5 ± 1.5 cm H2O) and was statistically significant (p < 0.001). The success rate of insertion of i-gel™ and LMA Supreme™ was similar (95% and 97.5% respectively). The ease of insertion for both devices was statistically similar (p = 0.593). The mean time for insertion was longer for i-gel™ (15.4 ± 1.72 s vs 12.4 ± 1.73 s) as compared to LMA Supreme™ (p < 0.001). Ventilatory parameters for both devices decreased in the lateral position, which was statistically significant. The fractional volume loss after change of position was 0.123 vs 0.478 for i-gel™ and LMA Supreme™ respectively. In both groups, fiberoptic views worsened with a change of position. Conclusions Oropharyngeal leak pressure of both devices reduced in lateral position as compared to supine position. I-gel™ yielded higher leak pressures in supine as well as in lateral position as compared to LMA Supreme™. Implications The above findings offer valuable insight for decision-making in pediatric daycare surgeries requiring lateral position where GA is warranted. Trial registration CTRI NUMBER (CTRI/2021/01/030442)—the trial was registered with the Clinical Trial Registry of India on 13 January 2021. |
| format | Article |
| id | doaj-daabd7a16eea464ab0695286beade76c |
| institution | Directory of Open Access Journals |
| issn | 2090-925X |
| language | English |
| publishDate | 2023-03-01 |
| publisher | https://asja.journals.ekb.eg/ |
| record_format | Article |
| spelling | doaj-daabd7a16eea464ab0695286beade76c2025-11-02T23:29:20Zenghttps://asja.journals.ekb.eg/Ain Shams Journal of Anesthesiology2090-925X2023-03-011511810.1186/s42077-023-00315-9A randomized controlled study to compare oropharyngeal leak pressure between I-gel™ and laryngeal mask airway supreme™ in children in lateral position under general anesthesiaRaksha Kundal0Kriti Puri1Garima Agrawal2Ranju Singh3Maitree Pandey4Department of Anesthesiology, AIIMSDepartment of Anesthesiology, Kovai Medical Centre Hospital Institute of Health Sciences and ResearchDepartment of Anesthesiology, Lady Hardinge Medical College and Associated HospitalsDepartment of Anesthesiology, Lady Hardinge Medical College and Associated HospitalsDepartment of Anesthesiology, Lady Hardinge Medical College and Associated HospitalsAbstract Background Supraglottic airway devices (SADs) are the mainstay for airway management in pediatric ambulatory surgeries and may often be a suitable alternative to endotracheal intubation due to their favorable profile. Optimal oropharyngeal leak pressure of SAD is essential for adequate ventilation and prevention of aspiration. Occasionally, lateral position is required for administration of regional block or for the surgery itself. We aim to compare the oropharyngeal leak pressure of igel™ and LMA Supreme™ in children in lateral position. A prospective, randomized study was performed on eighty children of either sex, weighing 5–10 kg, belonging to ASA grade I and II undergoing elective surgery requiring lateral position. The primary objective was comparison of Oropharyngeal leak pressure of both devices in lateral position. Secondary objectives included assessment of insertion success rate, number of insertion attempts and manipulations, time and ease of insertion; and comparison of fiberoptic view of the larynx, fractional volume loss, and displacement with respect to both devices in supine and lateral position. Results Oropharyngeal leak pressure of i-gel™ was higher than that of LMA Supreme™ in both supine (25.4 ± 1.4 cm H2O Vs 22.9 ± 1.5 cm H2O) and lateral position (23.9 ± 1.6 vs 21.5 ± 1.5 cm H2O) and was statistically significant (p < 0.001). The success rate of insertion of i-gel™ and LMA Supreme™ was similar (95% and 97.5% respectively). The ease of insertion for both devices was statistically similar (p = 0.593). The mean time for insertion was longer for i-gel™ (15.4 ± 1.72 s vs 12.4 ± 1.73 s) as compared to LMA Supreme™ (p < 0.001). Ventilatory parameters for both devices decreased in the lateral position, which was statistically significant. The fractional volume loss after change of position was 0.123 vs 0.478 for i-gel™ and LMA Supreme™ respectively. In both groups, fiberoptic views worsened with a change of position. Conclusions Oropharyngeal leak pressure of both devices reduced in lateral position as compared to supine position. I-gel™ yielded higher leak pressures in supine as well as in lateral position as compared to LMA Supreme™. Implications The above findings offer valuable insight for decision-making in pediatric daycare surgeries requiring lateral position where GA is warranted. Trial registration CTRI NUMBER (CTRI/2021/01/030442)—the trial was registered with the Clinical Trial Registry of India on 13 January 2021.https://doi.org/10.1186/s42077-023-00315-9Laryngeal mask airwayPediatricsMechanical ventilation |
| spellingShingle | Raksha Kundal Kriti Puri Garima Agrawal Ranju Singh Maitree Pandey A randomized controlled study to compare oropharyngeal leak pressure between I-gel™ and laryngeal mask airway supreme™ in children in lateral position under general anesthesia Laryngeal mask airway Pediatrics Mechanical ventilation |
| title | A randomized controlled study to compare oropharyngeal leak pressure between I-gel™ and laryngeal mask airway supreme™ in children in lateral position under general anesthesia |
| title_full | A randomized controlled study to compare oropharyngeal leak pressure between I-gel™ and laryngeal mask airway supreme™ in children in lateral position under general anesthesia |
| title_fullStr | A randomized controlled study to compare oropharyngeal leak pressure between I-gel™ and laryngeal mask airway supreme™ in children in lateral position under general anesthesia |
| title_full_unstemmed | A randomized controlled study to compare oropharyngeal leak pressure between I-gel™ and laryngeal mask airway supreme™ in children in lateral position under general anesthesia |
| title_short | A randomized controlled study to compare oropharyngeal leak pressure between I-gel™ and laryngeal mask airway supreme™ in children in lateral position under general anesthesia |
| title_sort | randomized controlled study to compare oropharyngeal leak pressure between i gel™ and laryngeal mask airway supreme™ in children in lateral position under general anesthesia |
| topic | Laryngeal mask airway Pediatrics Mechanical ventilation |
| url | https://doi.org/10.1186/s42077-023-00315-9 |
| work_keys_str_mv | AT rakshakundal arandomizedcontrolledstudytocompareoropharyngealleakpressurebetweenigelandlaryngealmaskairwaysupremeinchildreninlateralpositionundergeneralanesthesia AT kritipuri arandomizedcontrolledstudytocompareoropharyngealleakpressurebetweenigelandlaryngealmaskairwaysupremeinchildreninlateralpositionundergeneralanesthesia AT garimaagrawal arandomizedcontrolledstudytocompareoropharyngealleakpressurebetweenigelandlaryngealmaskairwaysupremeinchildreninlateralpositionundergeneralanesthesia AT ranjusingh arandomizedcontrolledstudytocompareoropharyngealleakpressurebetweenigelandlaryngealmaskairwaysupremeinchildreninlateralpositionundergeneralanesthesia AT maitreepandey arandomizedcontrolledstudytocompareoropharyngealleakpressurebetweenigelandlaryngealmaskairwaysupremeinchildreninlateralpositionundergeneralanesthesia AT rakshakundal randomizedcontrolledstudytocompareoropharyngealleakpressurebetweenigelandlaryngealmaskairwaysupremeinchildreninlateralpositionundergeneralanesthesia AT kritipuri randomizedcontrolledstudytocompareoropharyngealleakpressurebetweenigelandlaryngealmaskairwaysupremeinchildreninlateralpositionundergeneralanesthesia AT garimaagrawal randomizedcontrolledstudytocompareoropharyngealleakpressurebetweenigelandlaryngealmaskairwaysupremeinchildreninlateralpositionundergeneralanesthesia AT ranjusingh randomizedcontrolledstudytocompareoropharyngealleakpressurebetweenigelandlaryngealmaskairwaysupremeinchildreninlateralpositionundergeneralanesthesia AT maitreepandey randomizedcontrolledstudytocompareoropharyngealleakpressurebetweenigelandlaryngealmaskairwaysupremeinchildreninlateralpositionundergeneralanesthesia |
