Intraocular Lens Elongation Technique with Haptic Modification for Sulcus Implantation

Objectives:To define a haptic modification technique to increase the overall length of the intraocular lens (IOL) and evaluate the postoperative outcomes of patients in whom this technique was applied.Materials and Methods:The preoperative and postoperative characteristics of patients who underwent...

Full description

Bibliographic Details
Published in:Türk Oftalmoloji Dergisi
Main Authors: Mehmet Baykara, Gamze Uçan Gündüz, Ayşe Çetin Efe, Ceren Yurttaş
Format: Article
Language:English
Published: Turkish Ophthalmology Society 2022-08-01
Subjects:
Online Access: http://www.oftalmoloji.org/archives/archive-detail/article-preview/ntraocular-lens-elongation-technique-with-haptic-m/52727
_version_ 1848652006400458752
author Mehmet Baykara
Gamze Uçan Gündüz
Ayşe Çetin Efe
Ceren Yurttaş
author_facet Mehmet Baykara
Gamze Uçan Gündüz
Ayşe Çetin Efe
Ceren Yurttaş
author_sort Mehmet Baykara
collection DOAJ
container_title Türk Oftalmoloji Dergisi
description Objectives:To define a haptic modification technique to increase the overall length of the intraocular lens (IOL) and evaluate the postoperative outcomes of patients in whom this technique was applied.Materials and Methods:The preoperative and postoperative characteristics of patients who underwent modified IOL implantation into the sulcus between May 2019 and December 2019 were evaluated. Modified Sensar AR40e lenses with hydrophobic acrylic optic and polymethylmethacrylate haptics were implanted to all eyes. Before implanting the IOL, the haptics were grasped with two toothless forceps and bent to elongate the total diameter of the IOL from 13.0 mm to 14.5 mm.Results:The study included 11 eyes of 11 patients who underwent modified three-piece IOL implantation into the sulcus due to insufficient capsular support. The mean age of the patients was 53.9±12.2 years. The mean axial length was 24.13±1.93 mm. Sulcus implantation was required due to aphakia in 9 eyes and IOL dislocation in 2 eyes. No haptic breakage occurred during the IOL modification technique or implantation. The mean preoperative best corrected visual acuity (BCVA) was 0.88±1.1 logMAR, while postoperative BCVA was 0.28±0.30 logMAR. No IOL dislocation or decentration was observed during 6-month postoperative follow-up.Conclusion:The larger diameter lenses obtained with this inexpensive and easily applicable technique may allow a more stable sulcus implantation in eyes with inadequate capsular support.
format Article
id doaj-db6f8ebc66ca4d1eb2c2cfbe80e51ca4
institution Directory of Open Access Journals
issn 1300-0659
2147-2661
language English
publishDate 2022-08-01
publisher Turkish Ophthalmology Society
record_format Article
spelling doaj-db6f8ebc66ca4d1eb2c2cfbe80e51ca42025-11-02T23:34:12ZengTurkish Ophthalmology SocietyTürk Oftalmoloji Dergisi1300-06592147-26612022-08-0152422322710.4274/tjo.galenos.2021.3827513049054Intraocular Lens Elongation Technique with Haptic Modification for Sulcus ImplantationMehmet Baykara0Gamze Uçan Gündüz1Ayşe Çetin Efe2Ceren Yurttaş3 Bursa Uludağ Üniversitesi Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, Bursa, Türkiye Bursa Uludağ Üniversitesi Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, Bursa, Türkiye Erzurum Hınıs Şehit Yavuz Yürekseven Devlet Hastanesi, Göz Hastalıkları Kliniği, Erzurum, Türkiye Bursa Uludağ Üniversitesi Tıp Fakültesi, Anesteziyoloji ve Reanimasyon Anabilim Dalı, Bursa, Türkiye Objectives:To define a haptic modification technique to increase the overall length of the intraocular lens (IOL) and evaluate the postoperative outcomes of patients in whom this technique was applied.Materials and Methods:The preoperative and postoperative characteristics of patients who underwent modified IOL implantation into the sulcus between May 2019 and December 2019 were evaluated. Modified Sensar AR40e lenses with hydrophobic acrylic optic and polymethylmethacrylate haptics were implanted to all eyes. Before implanting the IOL, the haptics were grasped with two toothless forceps and bent to elongate the total diameter of the IOL from 13.0 mm to 14.5 mm.Results:The study included 11 eyes of 11 patients who underwent modified three-piece IOL implantation into the sulcus due to insufficient capsular support. The mean age of the patients was 53.9±12.2 years. The mean axial length was 24.13±1.93 mm. Sulcus implantation was required due to aphakia in 9 eyes and IOL dislocation in 2 eyes. No haptic breakage occurred during the IOL modification technique or implantation. The mean preoperative best corrected visual acuity (BCVA) was 0.88±1.1 logMAR, while postoperative BCVA was 0.28±0.30 logMAR. No IOL dislocation or decentration was observed during 6-month postoperative follow-up.Conclusion:The larger diameter lenses obtained with this inexpensive and easily applicable technique may allow a more stable sulcus implantation in eyes with inadequate capsular support. http://www.oftalmoloji.org/archives/archive-detail/article-preview/ntraocular-lens-elongation-technique-with-haptic-m/52727 aphakiaintraocular lens implantationlens dislocationciliary sulcus
spellingShingle Mehmet Baykara
Gamze Uçan Gündüz
Ayşe Çetin Efe
Ceren Yurttaş
Intraocular Lens Elongation Technique with Haptic Modification for Sulcus Implantation
aphakia
intraocular lens implantation
lens dislocation
ciliary sulcus
title Intraocular Lens Elongation Technique with Haptic Modification for Sulcus Implantation
title_full Intraocular Lens Elongation Technique with Haptic Modification for Sulcus Implantation
title_fullStr Intraocular Lens Elongation Technique with Haptic Modification for Sulcus Implantation
title_full_unstemmed Intraocular Lens Elongation Technique with Haptic Modification for Sulcus Implantation
title_short Intraocular Lens Elongation Technique with Haptic Modification for Sulcus Implantation
title_sort intraocular lens elongation technique with haptic modification for sulcus implantation
topic aphakia
intraocular lens implantation
lens dislocation
ciliary sulcus
url http://www.oftalmoloji.org/archives/archive-detail/article-preview/ntraocular-lens-elongation-technique-with-haptic-m/52727
work_keys_str_mv AT mehmetbaykara intraocularlenselongationtechniquewithhapticmodificationforsulcusimplantation
AT gamzeucangunduz intraocularlenselongationtechniquewithhapticmodificationforsulcusimplantation
AT aysecetinefe intraocularlenselongationtechniquewithhapticmodificationforsulcusimplantation
AT cerenyurttas intraocularlenselongationtechniquewithhapticmodificationforsulcusimplantation