Evaluation of pure-tone audiometric protocols in vestibular schwannoma screening

The objective was to evaluate the pure-tone audiogram-based screening protocols in VS diagnostics. We retrospectively analyzed presenting symptoms, pure tone audiometry and MRI finding from 246 VS patients and 442 controls were collected to test screening protocols (AAO-HNS, AMCLASS-A/B, Charing Cro...

Full description

Bibliographic Details
Published in:Journal of Otology
Main Authors: Matej Vnencak, Elina Huttunen, Antti A. Aarnisalo, Jussi Jero, Katja Liukkonen, Saku T. Sinkkonen
Format: Article
Language:English
Published: Tsinghua University Press 2021-07-01
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1672293020301185
_version_ 1848651684838899712
author Matej Vnencak
Elina Huttunen
Antti A. Aarnisalo
Jussi Jero
Katja Liukkonen
Saku T. Sinkkonen
author_facet Matej Vnencak
Elina Huttunen
Antti A. Aarnisalo
Jussi Jero
Katja Liukkonen
Saku T. Sinkkonen
author_sort Matej Vnencak
collection DOAJ
container_title Journal of Otology
description The objective was to evaluate the pure-tone audiogram-based screening protocols in VS diagnostics. We retrospectively analyzed presenting symptoms, pure tone audiometry and MRI finding from 246 VS patients and 442 controls were collected to test screening protocols (AAO-HNS, AMCLASS-A/B, Charing Cross, Cueva, DOH, Nashville, Oxford, Rule3000, Schlauch, Seattle, Sunderland) for sensitivity and specificity. Results were pooled with data from five other studies, and analysis of sensitivity, specificity and positive likelihood ratio (LR+) for each protocol was performed. Our results show that protocols with significantly higher sensitivity (AMCLASS-A/B, Nashville) show also significantly lowest specificity, and tend to have low association (positive likelihood ratio, LR+) to the VS. The highest LR+ was found for protocols AAO-HNS, Rule3000 and Seattle. In conclusions, knowing their properties, screening protocols are simple decision-making tools in VS diagnostic. To use the advantage of the highest sensitivity, protocols AMCLASS-A + B or Nashville can be of choice. For more reasonable approach, applying the protocols with high LR+ (AAO-HNS, Rule3000, Seattle) may reduce the overall number of MRI scans at expense of only few primarily undiagnosed VS.
format Article
id doaj-e2cf5b98c8d443d7ad983fb6d98a875c
institution Directory of Open Access Journals
issn 1672-2930
language English
publishDate 2021-07-01
publisher Tsinghua University Press
record_format Article
spelling doaj-e2cf5b98c8d443d7ad983fb6d98a875c2025-11-03T00:22:55ZengTsinghua University PressJournal of Otology1672-29302021-07-0116313814310.1016/j.joto.2020.12.004Evaluation of pure-tone audiometric protocols in vestibular schwannoma screeningMatej Vnencak0Elina Huttunen1Antti A. Aarnisalo2Jussi Jero3Katja Liukkonen4Saku T. Sinkkonen5Department of Otorhinolaryngology - Head and Neck Surgery, Turku University Hospital, Turku, Finland; Head and Neck Center, Otorhinolaryngology - Head and Neck Surgery, Helsinki University Hospital, And University of Helsinki, Helsinki, FinlandHead and Neck Center, Otorhinolaryngology - Head and Neck Surgery, Helsinki University Hospital, And University of Helsinki, Helsinki, FinlandHead and Neck Center, Otorhinolaryngology - Head and Neck Surgery, Helsinki University Hospital, And University of Helsinki, Helsinki, FinlandHead and Neck Center, Otorhinolaryngology - Head and Neck Surgery, Helsinki University Hospital, And University of Helsinki, Helsinki, FinlandHead and Neck Center, Otorhinolaryngology - Head and Neck Surgery, Helsinki University Hospital, And University of Helsinki, Helsinki, FinlandHead and Neck Center, Otorhinolaryngology - Head and Neck Surgery, Helsinki University Hospital, And University of Helsinki, Helsinki, Finland; Corresponding author. Head and Neck Center, Otorhinolaryngology – Head and Neck Surgery, Helsinki University Hospital, POB 263, 00029 HUS, Helsinki, Finland.The objective was to evaluate the pure-tone audiogram-based screening protocols in VS diagnostics. We retrospectively analyzed presenting symptoms, pure tone audiometry and MRI finding from 246 VS patients and 442 controls were collected to test screening protocols (AAO-HNS, AMCLASS-A/B, Charing Cross, Cueva, DOH, Nashville, Oxford, Rule3000, Schlauch, Seattle, Sunderland) for sensitivity and specificity. Results were pooled with data from five other studies, and analysis of sensitivity, specificity and positive likelihood ratio (LR+) for each protocol was performed. Our results show that protocols with significantly higher sensitivity (AMCLASS-A/B, Nashville) show also significantly lowest specificity, and tend to have low association (positive likelihood ratio, LR+) to the VS. The highest LR+ was found for protocols AAO-HNS, Rule3000 and Seattle. In conclusions, knowing their properties, screening protocols are simple decision-making tools in VS diagnostic. To use the advantage of the highest sensitivity, protocols AMCLASS-A + B or Nashville can be of choice. For more reasonable approach, applying the protocols with high LR+ (AAO-HNS, Rule3000, Seattle) may reduce the overall number of MRI scans at expense of only few primarily undiagnosed VS.http://www.sciencedirect.com/science/article/pii/S1672293020301185Vestibular schwannomaAsymmetric sensorineural hearing lossScreening protocol
spellingShingle Matej Vnencak
Elina Huttunen
Antti A. Aarnisalo
Jussi Jero
Katja Liukkonen
Saku T. Sinkkonen
Evaluation of pure-tone audiometric protocols in vestibular schwannoma screening
Vestibular schwannoma
Asymmetric sensorineural hearing loss
Screening protocol
title Evaluation of pure-tone audiometric protocols in vestibular schwannoma screening
title_full Evaluation of pure-tone audiometric protocols in vestibular schwannoma screening
title_fullStr Evaluation of pure-tone audiometric protocols in vestibular schwannoma screening
title_full_unstemmed Evaluation of pure-tone audiometric protocols in vestibular schwannoma screening
title_short Evaluation of pure-tone audiometric protocols in vestibular schwannoma screening
title_sort evaluation of pure tone audiometric protocols in vestibular schwannoma screening
topic Vestibular schwannoma
Asymmetric sensorineural hearing loss
Screening protocol
url http://www.sciencedirect.com/science/article/pii/S1672293020301185
work_keys_str_mv AT matejvnencak evaluationofpuretoneaudiometricprotocolsinvestibularschwannomascreening
AT elinahuttunen evaluationofpuretoneaudiometricprotocolsinvestibularschwannomascreening
AT anttiaaarnisalo evaluationofpuretoneaudiometricprotocolsinvestibularschwannomascreening
AT jussijero evaluationofpuretoneaudiometricprotocolsinvestibularschwannomascreening
AT katjaliukkonen evaluationofpuretoneaudiometricprotocolsinvestibularschwannomascreening
AT sakutsinkkonen evaluationofpuretoneaudiometricprotocolsinvestibularschwannomascreening