A novel, new generation drill coating for osteotomy site preparation

Background: Implant success and survival rate ranges from 93% to 97%; however, failures are not very uncommon. These failures can be caused due to a variety of reasons out of which increased heat during drilling of osteotomies is a major contributor.Aim: The aim of this study was to develop a new ge...

Full description

Bibliographic Details
Main Authors: Pooja P Wadkar, Suraj Khalap, Devanand Shetty, Abhishek Gupta, Arvind Shetty, Suyog Dharmadhikari
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2019-01-01
Series:Indian Journal of Dental Research
Subjects:
Online Access:http://www.ijdr.in/article.asp?issn=0970-9290;year=2019;volume=30;issue=5;spage=767;epage=771;aulast=Wadkar