Seismic Performance of Large Underground Water Tank Structures Considering Fluid–Structure Interaction

The widespread application of large underground water tank structures in urban areas necessitates reliable design guidelines to ensure their safety as critical infrastructure. This paper investigated the seismic response of large underground water tank structures considering fluid–structure interact...

Full description

Bibliographic Details
Published in:Buildings
Main Authors: Fengyuan Xu, Chengshun Xu, Mohamed Hesham El Naggar, Xiuli Du
Format: Article
Language:English
Published: MDPI AG 2025-07-01
Subjects:
Online Access:https://www.mdpi.com/2075-5309/15/15/2643