Determining Adequate Averaging Periods and Reference Coordinates for Eddy Covariance Measurements of Surface Heat and Water Vapor Fluxes over Mountainous Terrain
Two coordinate rotation approaches (double and planar-fit rotations) and no rotation, in association with averaging periods of 15 - 480 min, were applied to compute surface heat and water vapor fluxes using the eddy covariance approach. Measurements were conducted in an experimental watershed, the L...
| Published in: | Terrestrial, Atmospheric and Oceanic Sciences |
|---|---|
| Main Author: | |
| Format: | Article |
| Language: | English |
| Published: |
Springer
2012-01-01
|
| Subjects: | |
| Online Access: |
http://tao.cgu.org.tw/images/attachments/v236p685.pdf
|