Experimental Study on Denitration Transformation of CFB Boiler Burning Fujian Anthracite
Two 75 t/h medium-temperature separated circulating fluidized bed boilers burning Fujian anthracite were upgraded with low NOx combustion (LNC). By reducing the effective cross-sectional area of the air distributor (from 13.43 m<sup>2</sup> to 11.38 m<sup>2</sup>), improving...