Simulation and transient analyses of a complete passive heat removal system in a downward cooling pool-type material testing reactor against a complete station blackout and long-term natural convection mode using the RELAP5/3.2 code
In this paper, a complete station blackout (SBO) or complete loss of electrical power supplies is simulated and analyzed in a downward cooling 5-MW pool-type Material Testing Reactor (MTR). The scenario is traced in the absence of active cooling systems and operators. The code nodalization is succes...
| Published in: | Nuclear Engineering and Technology |
|---|---|
| Main Author: | |
| Format: | Article |
| Language: | English |
| Published: |
Elsevier
2017-08-01
|
| Subjects: | |
| Online Access: | http://www.sciencedirect.com/science/article/pii/S1738573317302413 |
