Influence Factor Analysis and Application of Ultrasonic Method for Identifying Cable Clamp Blot Axial Force in Suspension Bridge

To effectively evaluate the loss of axial force for the bolts in cable clamp of suspension bridge, the influence factors analyses and application of ultrasonic identification method for cable clamp blot axial force in suspension bridge were carried out. Firstly, the axial force calculation formula w...

Full description

Bibliographic Details
Published in:工程科学与技术
Main Authors: Xin CHEN, Jingsong ZHU, Zhongtao YE, Jianjun YI
Format: Article
Language:English
Published: Editorial Department of Journal of Sichuan University (Engineering Science Edition) 2021-11-01
Subjects:
Online Access:http://jsuese.scu.edu.cn/thesisDetails#10.15961/j.jsuese.202000930