Perigraft seroma penetrating the aortic sac and rupturing into the intraperitoneal cavity

We present a case of a 66-year-old woman who developed perigraft seroma after having undergone elective, open abdominal aortic aneurysm repair with a polytetrafluoroethylene graft 5 years previously. One year after graft implantation, she started to suffer from abdominal discomfort and was therefore...

Full description

Bibliographic Details
Main Authors: Magdalena Broda, MD, Jacob Budtz-Lilly, MD, Sten Vammen, MD, PhD, Steen Fjord Pedersen, MD, PhD
Format: Article
Language:English
Published: Elsevier 2019-09-01
Series:Journal of Vascular Surgery Cases and Innovative Techniques
Online Access:http://www.sciencedirect.com/science/article/pii/S2468428719300620
Description
Summary:We present a case of a 66-year-old woman who developed perigraft seroma after having undergone elective, open abdominal aortic aneurysm repair with a polytetrafluoroethylene graft 5 years previously. One year after graft implantation, she started to suffer from abdominal discomfort and was therefore offered surgical intervention, which she declined owing to the fear of postoperative complications. Instead, an observational strategy was used. Five years later, the patient presented with sudden severe abdominal pain. Subsequent laparotomy revealed that the pseudomembrane lining the perigraft seroma had penetrated through the native aortic wall and into the intraperitoneal cavity, where it had ruptured. The patient was successfully treated by replacing the polytetrafluoroethylene graft with a polyethylene terephthalate (Dacron) graft. Keywords: Perigraft seroma, Abdominal aortic aneurysm, Infection