A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE (PPIUCD) WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICE
Objective: To compare the safety and efficacy of post partum intrauterine contraceptive device with interval intrauterine contraceptive device, to avoid unplanned pregnancies. Study Design: Quasi-experimental study. Place and Duration of Study: Gynaecology and Obstetrics Department, Combined M...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
The Army Press
2020-10-01
|
Series: | Pakistan Armed Forces Medical Journal |
Subjects: | |
Online Access: | https://pafmj.org/index.php/PAFMJ/article/view/5576 |
id |
doaj-021b065d8e0e4c3a9a9ae7b28cfc2630 |
---|---|
record_format |
Article |
spelling |
doaj-021b065d8e0e4c3a9a9ae7b28cfc26302021-09-12T08:54:14ZengThe Army PressPakistan Armed Forces Medical Journal0030-96482411-88422020-10-0170514191423A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE (PPIUCD) WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICENadia Arif0Bushra Zafar1Raja Qaseem Ahmed2Farrukh Shehzad3Combined Military Hospital Okara PakistanCombined Military Hospital Okara PakistanCombined Military Hospital Okara PakistanCombined Military Hospital Okara PakistanObjective: To compare the safety and efficacy of post partum intrauterine contraceptive device with interval intrauterine contraceptive device, to avoid unplanned pregnancies. Study Design: Quasi-experimental study. Place and Duration of Study: Gynaecology and Obstetrics Department, Combined Military Hospital (CMH) Okara, from Aug 2019 to Jul 2020 Methodology: One hundred patients were included in the study. Divided in 2 groups, group A (post partum intrauterine contraceptive device, n=50) patients underwent cesarean section under spinal anesthesia, after removal of placenta and membranes contraceptive device was placed near fundus with fingers and incision was closed. In group B (interval intrauterine contraceptive device, n=50) and intrauterine contraceptive device was placed 6 weeks postpartum. Post insertion follow up was at 6 weeks and then 6 months. Efficacy was assessed by the continuation rate and safety, by presence or otherwise of heavy menstrual bleeding, lost threads, abnormal vaginal discharge and pain abdomen on follow up visits. Results: Efficacy in group A was 46 (92%) and in group B 40 (80%). Safety that is heavy menstrual bleeding 3 (6%) and 5 (10%), lost threads 3 (6%) and 1 (2%), abnormal vaginal discharge 2 (4%), and 3 (6%), and pain abdomen 1 (2%) and 2 (4%) in groups A and B respectively. Conclusion: Postpartum intrauterine contraceptive device insertion was found to be effective and safe method as compared to interval intrauterine contraceptive device. Successful placement, continuation and retention rate were significantly higher in post placental intra uterine contraceptive device insertion.https://pafmj.org/index.php/PAFMJ/article/view/5576acceptabilitycontraceptionefficacyintrauterine contraceptive device |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Nadia Arif Bushra Zafar Raja Qaseem Ahmed Farrukh Shehzad |
spellingShingle |
Nadia Arif Bushra Zafar Raja Qaseem Ahmed Farrukh Shehzad A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE (PPIUCD) WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICE Pakistan Armed Forces Medical Journal acceptability contraception efficacy intrauterine contraceptive device |
author_facet |
Nadia Arif Bushra Zafar Raja Qaseem Ahmed Farrukh Shehzad |
author_sort |
Nadia Arif |
title |
A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE (PPIUCD) WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICE |
title_short |
A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE (PPIUCD) WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICE |
title_full |
A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE (PPIUCD) WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICE |
title_fullStr |
A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE (PPIUCD) WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICE |
title_full_unstemmed |
A STUDY ON THE COMPARISON OF SAFETY AND EFFICACY OF POST PARTUM INTRAUTERINE CONTRACEPTIVE DEVICE (PPIUCD) WITH INTERVAL INTRAUTERINE CONTRACEPTIVE DEVICE |
title_sort |
study on the comparison of safety and efficacy of post partum intrauterine contraceptive device (ppiucd) with interval intrauterine contraceptive device |
publisher |
The Army Press |
series |
Pakistan Armed Forces Medical Journal |
issn |
0030-9648 2411-8842 |
publishDate |
2020-10-01 |
description |
Objective: To compare the safety and efficacy of post partum intrauterine contraceptive device with interval intrauterine contraceptive device, to avoid unplanned pregnancies.
Study Design: Quasi-experimental study.
Place and Duration of Study: Gynaecology and Obstetrics Department, Combined Military Hospital (CMH) Okara, from Aug 2019 to Jul 2020
Methodology: One hundred patients were included in the study. Divided in 2 groups, group A (post partum intrauterine contraceptive device, n=50) patients underwent cesarean section under spinal anesthesia, after removal of placenta and membranes contraceptive device was placed near fundus with fingers and incision was closed. In group B (interval intrauterine contraceptive device, n=50) and intrauterine contraceptive device was placed 6 weeks postpartum. Post insertion follow up was at 6 weeks and then 6 months. Efficacy was assessed by the continuation rate and safety, by presence or otherwise of heavy menstrual bleeding, lost threads, abnormal vaginal discharge and pain abdomen on follow up visits.
Results: Efficacy in group A was 46 (92%) and in group B 40 (80%). Safety that is heavy menstrual bleeding 3 (6%) and 5 (10%), lost threads 3 (6%) and 1 (2%), abnormal vaginal discharge 2 (4%), and 3 (6%), and pain abdomen 1 (2%) and 2 (4%) in groups A and B respectively.
Conclusion: Postpartum intrauterine contraceptive device insertion was found to be effective and safe method as compared to interval intrauterine contraceptive device. Successful placement, continuation and retention rate were significantly higher in post placental intra uterine contraceptive device insertion. |
topic |
acceptability contraception efficacy intrauterine contraceptive device |
url |
https://pafmj.org/index.php/PAFMJ/article/view/5576 |
work_keys_str_mv |
AT nadiaarif astudyonthecomparisonofsafetyandefficacyofpostpartumintrauterinecontraceptivedeviceppiucdwithintervalintrauterinecontraceptivedevice AT bushrazafar astudyonthecomparisonofsafetyandefficacyofpostpartumintrauterinecontraceptivedeviceppiucdwithintervalintrauterinecontraceptivedevice AT rajaqaseemahmed astudyonthecomparisonofsafetyandefficacyofpostpartumintrauterinecontraceptivedeviceppiucdwithintervalintrauterinecontraceptivedevice AT farrukhshehzad astudyonthecomparisonofsafetyandefficacyofpostpartumintrauterinecontraceptivedeviceppiucdwithintervalintrauterinecontraceptivedevice AT nadiaarif studyonthecomparisonofsafetyandefficacyofpostpartumintrauterinecontraceptivedeviceppiucdwithintervalintrauterinecontraceptivedevice AT bushrazafar studyonthecomparisonofsafetyandefficacyofpostpartumintrauterinecontraceptivedeviceppiucdwithintervalintrauterinecontraceptivedevice AT rajaqaseemahmed studyonthecomparisonofsafetyandefficacyofpostpartumintrauterinecontraceptivedeviceppiucdwithintervalintrauterinecontraceptivedevice AT farrukhshehzad studyonthecomparisonofsafetyandefficacyofpostpartumintrauterinecontraceptivedeviceppiucdwithintervalintrauterinecontraceptivedevice |
_version_ |
1717756028496379904 |