Temperature Measurement and Control Application in a Laser Plastic Surgery Real Temperature Detection System

The purpose of this study was to grasp the development process of thermal image temperature measurement technology. It provides directional support for the optimization development of the thermal imagery and laser plastic surgery and laser treatment. This paper uses the infrared thermal image temper...

Full description

Bibliographic Details
Main Authors: Hong Wei, Fang Jiang, Fang Shao, Denghui Zhang, Fang Gu, Ying Yang, Qiuxia Chen, Zheng Ai
Format: Article
Language:English
Published: Hindawi Limited 2021-01-01
Series:Scientific Programming
Online Access:http://dx.doi.org/10.1155/2021/8382482
id doaj-02ae119474c546e38d672c1c31b6aa58
record_format Article
spelling doaj-02ae119474c546e38d672c1c31b6aa582021-10-11T00:39:32ZengHindawi LimitedScientific Programming1875-919X2021-01-01202110.1155/2021/8382482Temperature Measurement and Control Application in a Laser Plastic Surgery Real Temperature Detection SystemHong Wei0Fang Jiang1Fang Shao2Denghui Zhang3Fang Gu4Ying Yang5Qiuxia Chen6Zheng Ai7Tianyou Hospital Affiliated to Wuhan University of Science & TechnologyTianyou Hospital Affiliated to Wuhan University of Science & TechnologyTianyou Hospital Affiliated to Wuhan University of Science & TechnologyTianyou Hospital Affiliated to Wuhan University of Science & TechnologyZhejiang Provincial People's HospitalTianyou Hospital Affiliated to Wuhan University of Science & TechnologyTianyou Hospital Affiliated to Wuhan University of Science & TechnologyTianyou Hospital Affiliated to Wuhan University of Science & TechnologyThe purpose of this study was to grasp the development process of thermal image temperature measurement technology. It provides directional support for the optimization development of the thermal imagery and laser plastic surgery and laser treatment. This paper uses the infrared thermal image temperature measurement principle and performs infrared thermal image precise temperature measurement technology and its application research. The results showed that there was a correlation between 595 nm pulse dye laser, age, laser energy density, and skin temperature (P<0.05). There is a significant difference in the average (P<0.05). The infrared thermal imagery temperature monitoring system is a simple and relatively accurate temperature detection system that can be widely used in temperature measurement and control of laser plastic surgery.http://dx.doi.org/10.1155/2021/8382482
collection DOAJ
language English
format Article
sources DOAJ
author Hong Wei
Fang Jiang
Fang Shao
Denghui Zhang
Fang Gu
Ying Yang
Qiuxia Chen
Zheng Ai
spellingShingle Hong Wei
Fang Jiang
Fang Shao
Denghui Zhang
Fang Gu
Ying Yang
Qiuxia Chen
Zheng Ai
Temperature Measurement and Control Application in a Laser Plastic Surgery Real Temperature Detection System
Scientific Programming
author_facet Hong Wei
Fang Jiang
Fang Shao
Denghui Zhang
Fang Gu
Ying Yang
Qiuxia Chen
Zheng Ai
author_sort Hong Wei
title Temperature Measurement and Control Application in a Laser Plastic Surgery Real Temperature Detection System
title_short Temperature Measurement and Control Application in a Laser Plastic Surgery Real Temperature Detection System
title_full Temperature Measurement and Control Application in a Laser Plastic Surgery Real Temperature Detection System
title_fullStr Temperature Measurement and Control Application in a Laser Plastic Surgery Real Temperature Detection System
title_full_unstemmed Temperature Measurement and Control Application in a Laser Plastic Surgery Real Temperature Detection System
title_sort temperature measurement and control application in a laser plastic surgery real temperature detection system
publisher Hindawi Limited
series Scientific Programming
issn 1875-919X
publishDate 2021-01-01
description The purpose of this study was to grasp the development process of thermal image temperature measurement technology. It provides directional support for the optimization development of the thermal imagery and laser plastic surgery and laser treatment. This paper uses the infrared thermal image temperature measurement principle and performs infrared thermal image precise temperature measurement technology and its application research. The results showed that there was a correlation between 595 nm pulse dye laser, age, laser energy density, and skin temperature (P<0.05). There is a significant difference in the average (P<0.05). The infrared thermal imagery temperature monitoring system is a simple and relatively accurate temperature detection system that can be widely used in temperature measurement and control of laser plastic surgery.
url http://dx.doi.org/10.1155/2021/8382482
work_keys_str_mv AT hongwei temperaturemeasurementandcontrolapplicationinalaserplasticsurgeryrealtemperaturedetectionsystem
AT fangjiang temperaturemeasurementandcontrolapplicationinalaserplasticsurgeryrealtemperaturedetectionsystem
AT fangshao temperaturemeasurementandcontrolapplicationinalaserplasticsurgeryrealtemperaturedetectionsystem
AT denghuizhang temperaturemeasurementandcontrolapplicationinalaserplasticsurgeryrealtemperaturedetectionsystem
AT fanggu temperaturemeasurementandcontrolapplicationinalaserplasticsurgeryrealtemperaturedetectionsystem
AT yingyang temperaturemeasurementandcontrolapplicationinalaserplasticsurgeryrealtemperaturedetectionsystem
AT qiuxiachen temperaturemeasurementandcontrolapplicationinalaserplasticsurgeryrealtemperaturedetectionsystem
AT zhengai temperaturemeasurementandcontrolapplicationinalaserplasticsurgeryrealtemperaturedetectionsystem
_version_ 1716829085109321728