Summary: | Background and Objectives : Assessing only the clinical and radiographic parameters for evaluation of dental implants may not be enough as they often reflect extensive inflammatory changes in the periodontal tissues. As peri-implant crevicular fluid (PICF) can give us a more prompt and objective measure of the disease activity, the purpose of this case series is to assess the peri-implant health status of single tooth dental implants not only clinically and radiographically but also biochemically. Materials and Methods: Thirteen patients were subjected to dental implants at single edentulous sites using a conventional surgical approach. At baseline, 6 months, and 12 months after implant placement, the clinical and radiographic parameters were recorded. Additionally, IL-1β in PICF was estimated using the ELISA kit at 6 th and 12 th month. Results: The clinical and radiographic parameters differed significantly around the implants at different time intervals with IL-1β levels showing highly significant differences between 6 months (31.79 ± 12.26 pg/μl) and 12 months (113.09 ± 51.11 pg/μl). However, Spearman′s correlation coefficient showed no correlation with the clinical and radiographic parameters. Interpretation and Conclusion: Assessment of the various parameters confirmed that all the implants had a healthy peri-implant status. Although the levels of IL-1β in PICF were elevated at the 12 th month, they were well within the healthy range as observed by previous studies. This indicates that IL-1β, a biochemical marker, can be used as an adjunct to clinical and radiographic parameters in the assessment of EARLY inflammatory changes around implants.
|