Diagnostic Performance of Ultra-Low-Dose Computed Tomography for Detecting Asbestos-Related Pleuropulmonary Diseases: Prospective Study in a Screening Setting.

To evaluate the diagnostic performance of Ultra-Low-Dose Chest CT (ULD CT) for the detection of any asbestos-related lesions (primary endpoint) and specific asbestos-related abnormalities, i.e. non-calcified and calcified pleural plaques, diffuse pleural thickening, asbestosis and significant lung n...

Full description

Bibliographic Details
Main Authors: Marysa Schaal, François Severac, Aissam Labani, Mi-Young Jeung, Catherine Roy, Mickaël Ohana
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2016-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC5199059?pdf=render
Description
Summary:To evaluate the diagnostic performance of Ultra-Low-Dose Chest CT (ULD CT) for the detection of any asbestos-related lesions (primary endpoint) and specific asbestos-related abnormalities, i.e. non-calcified and calcified pleural plaques, diffuse pleural thickening, asbestosis and significant lung nodules (secondary endpoints).55 male patients (55.7±8.1 years old) with occupational asbestos exposure for at least 15 years and where CT screening was indicated were prospectively included. They all underwent a standard unenhanced chest CT (120kV, automated tube current modulation), considered as the reference, and an ULD CT (135kV, 10mA), both with iterative reconstruction. Two chest radiologists independently and blindly read the examinations, following a detailed protocol. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy and error rate of ULD CT were calculated using the exact method of Pearson with a confidence interval of 95%.Radiation dose was 17.9±1.2mGy.cm (0.25mSv) for the ULD-CT versus 288.8 ±151mGy.cm (4mSv); p <2.2e-16. Prevalence of abnormalities was 20%. The ULD CT's diagnostic performance in joint reading was high for the primary endpoint (sensitivity = 90.9%, specificity = 100%, positive predictive value = 100%, negative predictive value = 97.8%), high for lung nodules, diffuse pleural thickening and calcified pleural plaques (sensitivity, specificity, PPV and NPV = 100%) and fair for asbestosis (sensitivity = 75%, specificity = 100%, PPV = 00%, NPV = 98.1%). Intra-reader accuracy between the ULD CT and the reference CT for the primary endpoint was 98% for the senior and 100% for the junior radiologist. Inter-reader agreement for the primary endpoint was almost perfect (Cohen's Kappa of 0.81).ULD CT in the screening of asbestos exposure related diseases has 90.9% sensitivity and 100% specificity, and could therefore be proposed as a first line examination.
ISSN:1932-6203