New electrical impedance methods for the in situ measurement of the complex permittivity of anisotropic skeletal muscle using multipolar needles

Abstract This paper provides a rigorous analysis on the measurement of the permittivity of two-dimensional anisotropic biological tissues such as skeletal muscle using the four-electrode impedance technique. The state-of-the-art technique requires individual electrodes placed at the same depth in co...

Full description

Bibliographic Details
Main Authors: H. Kwon, M. Guasch, J. A. Nagy, S. B. Rutkove, B. Sanchez
Format: Article
Language:English
Published: Nature Publishing Group 2019-02-01
Series:Scientific Reports
Online Access:https://doi.org/10.1038/s41598-019-39277-0
id doaj-050baa825e3f42209602abb3f965a733
record_format Article
spelling doaj-050baa825e3f42209602abb3f965a7332020-12-08T08:52:51ZengNature Publishing GroupScientific Reports2045-23222019-02-019111610.1038/s41598-019-39277-0New electrical impedance methods for the in situ measurement of the complex permittivity of anisotropic skeletal muscle using multipolar needlesH. Kwon0M. Guasch1J. A. Nagy2S. B. Rutkove3B. Sanchez4Department of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical SchoolDepartment of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical SchoolDepartment of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical SchoolDepartment of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical SchoolDepartment of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical SchoolAbstract This paper provides a rigorous analysis on the measurement of the permittivity of two-dimensional anisotropic biological tissues such as skeletal muscle using the four-electrode impedance technique. The state-of-the-art technique requires individual electrodes placed at the same depth in contact with the anisotropic material, e.g. using monopolar needles. In this case, the minimum of measurements in different directions needed to estimate the complex permittivity and its anisotropy direction is 3, which translates into 12 monopolar needle insertions (i.e. 3 directions × 4 electrodes in each direction). Here, we extend our previous work and equip the reader with 8 new methods for multipolar needles, where 2 or more electrodes are spaced along the needle’s shaft in contact with the tissue at different depths. Using multipolar needles, the new methods presented reduce the number of needle insertions by a factor of 2 with respect to the available methods. We illustrate the methods with numerical simulations and new experiments on ex vivo ovine skeletal muscle (n = 3). Multi-frequency longitudinal and transverse permittivity data from 30 kHz to 1 MHz is made publicly available in the supplementary material. The methods presented here for multipolar needles bring closer the application of needle electrical impedance to patients with neuromuscular diseases.https://doi.org/10.1038/s41598-019-39277-0
collection DOAJ
language English
format Article
sources DOAJ
author H. Kwon
M. Guasch
J. A. Nagy
S. B. Rutkove
B. Sanchez
spellingShingle H. Kwon
M. Guasch
J. A. Nagy
S. B. Rutkove
B. Sanchez
New electrical impedance methods for the in situ measurement of the complex permittivity of anisotropic skeletal muscle using multipolar needles
Scientific Reports
author_facet H. Kwon
M. Guasch
J. A. Nagy
S. B. Rutkove
B. Sanchez
author_sort H. Kwon
title New electrical impedance methods for the in situ measurement of the complex permittivity of anisotropic skeletal muscle using multipolar needles
title_short New electrical impedance methods for the in situ measurement of the complex permittivity of anisotropic skeletal muscle using multipolar needles
title_full New electrical impedance methods for the in situ measurement of the complex permittivity of anisotropic skeletal muscle using multipolar needles
title_fullStr New electrical impedance methods for the in situ measurement of the complex permittivity of anisotropic skeletal muscle using multipolar needles
title_full_unstemmed New electrical impedance methods for the in situ measurement of the complex permittivity of anisotropic skeletal muscle using multipolar needles
title_sort new electrical impedance methods for the in situ measurement of the complex permittivity of anisotropic skeletal muscle using multipolar needles
publisher Nature Publishing Group
series Scientific Reports
issn 2045-2322
publishDate 2019-02-01
description Abstract This paper provides a rigorous analysis on the measurement of the permittivity of two-dimensional anisotropic biological tissues such as skeletal muscle using the four-electrode impedance technique. The state-of-the-art technique requires individual electrodes placed at the same depth in contact with the anisotropic material, e.g. using monopolar needles. In this case, the minimum of measurements in different directions needed to estimate the complex permittivity and its anisotropy direction is 3, which translates into 12 monopolar needle insertions (i.e. 3 directions × 4 electrodes in each direction). Here, we extend our previous work and equip the reader with 8 new methods for multipolar needles, where 2 or more electrodes are spaced along the needle’s shaft in contact with the tissue at different depths. Using multipolar needles, the new methods presented reduce the number of needle insertions by a factor of 2 with respect to the available methods. We illustrate the methods with numerical simulations and new experiments on ex vivo ovine skeletal muscle (n = 3). Multi-frequency longitudinal and transverse permittivity data from 30 kHz to 1 MHz is made publicly available in the supplementary material. The methods presented here for multipolar needles bring closer the application of needle electrical impedance to patients with neuromuscular diseases.
url https://doi.org/10.1038/s41598-019-39277-0
work_keys_str_mv AT hkwon newelectricalimpedancemethodsfortheinsitumeasurementofthecomplexpermittivityofanisotropicskeletalmuscleusingmultipolarneedles
AT mguasch newelectricalimpedancemethodsfortheinsitumeasurementofthecomplexpermittivityofanisotropicskeletalmuscleusingmultipolarneedles
AT janagy newelectricalimpedancemethodsfortheinsitumeasurementofthecomplexpermittivityofanisotropicskeletalmuscleusingmultipolarneedles
AT sbrutkove newelectricalimpedancemethodsfortheinsitumeasurementofthecomplexpermittivityofanisotropicskeletalmuscleusingmultipolarneedles
AT bsanchez newelectricalimpedancemethodsfortheinsitumeasurementofthecomplexpermittivityofanisotropicskeletalmuscleusingmultipolarneedles
_version_ 1724390150357647360