Effectiveness and Discussion of Ventilation Design with Automatic Revolving Window
This paper aims to improve and discuss the effectiveness of automatic revolving window ventilation on human comfort, where the temperature sensor mounted indoors gives the signal to start the stepping motor of the revolving window. There is a controller for automatic regulation according to the diff...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2016-01-01
|
Series: | MATEC Web of Conferences |
Online Access: | http://dx.doi.org/10.1051/matecconf/20164401083 |
id |
doaj-06722321a9044adba86728e65bf06577 |
---|---|
record_format |
Article |
spelling |
doaj-06722321a9044adba86728e65bf065772021-02-02T08:03:40ZengEDP SciencesMATEC Web of Conferences2261-236X2016-01-01440108310.1051/matecconf/20164401083matecconf_iceice2016_01083Effectiveness and Discussion of Ventilation Design with Automatic Revolving WindowChang Jing Yi0Kuan Yean Der1Lan Chun Ching2Li Hsing Ju3Hsu Yu Kun4Chen Chih Yao5Shen En Ting6Chen Chih Yen7Department of Marine Engineering, Taipei College of Maritime TechnologyDepartment of Refrigeration, Air-Conditioning and Energy Engineering, National Chi-Yi University of TechnologyDepartment of Refrigeration, Air-Conditioning and Energy Engineering, National Chi-Yi University of TechnologyDepartment of Refrigeration, Air-Conditioning and Energy Engineering, National Chi-Yi University of TechnologyDepartment of Refrigeration, Air-Conditioning and Energy Engineering, National Chi-Yi University of TechnologyDepartment of Refrigeration, Air-Conditioning and Energy Engineering, National Chi-Yi University of TechnologyDepartment of Refrigeration, Air-Conditioning and Energy Engineering, National Chi-Yi University of TechnologyDepartment of Marine Engineering, Taipei College of Maritime TechnologyThis paper aims to improve and discuss the effectiveness of automatic revolving window ventilation on human comfort, where the temperature sensor mounted indoors gives the signal to start the stepping motor of the revolving window. There is a controller for automatic regulation according to the difference between the preset temperature and indoor temperature, where the air flow of ventilating fan imports outside air to take excess heat away from the room, in order to reduce the indoor temperature. The revolving window opening angle is simulated and analyzed, and the impact of different air rates on the indoor temperature is analyzed. This system can regulate the indoor temperature to effectively reach the optimal human comfort temperature, and can reduce the frequency of using air conditioning, in order to attain the goals of energy saving, carbon reduction, and environmental protection.http://dx.doi.org/10.1051/matecconf/20164401083 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Chang Jing Yi Kuan Yean Der Lan Chun Ching Li Hsing Ju Hsu Yu Kun Chen Chih Yao Shen En Ting Chen Chih Yen |
spellingShingle |
Chang Jing Yi Kuan Yean Der Lan Chun Ching Li Hsing Ju Hsu Yu Kun Chen Chih Yao Shen En Ting Chen Chih Yen Effectiveness and Discussion of Ventilation Design with Automatic Revolving Window MATEC Web of Conferences |
author_facet |
Chang Jing Yi Kuan Yean Der Lan Chun Ching Li Hsing Ju Hsu Yu Kun Chen Chih Yao Shen En Ting Chen Chih Yen |
author_sort |
Chang Jing Yi |
title |
Effectiveness and Discussion of Ventilation Design with Automatic Revolving Window |
title_short |
Effectiveness and Discussion of Ventilation Design with Automatic Revolving Window |
title_full |
Effectiveness and Discussion of Ventilation Design with Automatic Revolving Window |
title_fullStr |
Effectiveness and Discussion of Ventilation Design with Automatic Revolving Window |
title_full_unstemmed |
Effectiveness and Discussion of Ventilation Design with Automatic Revolving Window |
title_sort |
effectiveness and discussion of ventilation design with automatic revolving window |
publisher |
EDP Sciences |
series |
MATEC Web of Conferences |
issn |
2261-236X |
publishDate |
2016-01-01 |
description |
This paper aims to improve and discuss the effectiveness of automatic revolving window ventilation on human comfort, where the temperature sensor mounted indoors gives the signal to start the stepping motor of the revolving window. There is a controller for automatic regulation according to the difference between the preset temperature and indoor temperature, where the air flow of ventilating fan imports outside air to take excess heat away from the room, in order to reduce the indoor temperature. The revolving window opening angle is simulated and analyzed, and the impact of different air rates on the indoor temperature is analyzed. This system can regulate the indoor temperature to effectively reach the optimal human comfort temperature, and can reduce the frequency of using air conditioning, in order to attain the goals of energy saving, carbon reduction, and environmental protection. |
url |
http://dx.doi.org/10.1051/matecconf/20164401083 |
work_keys_str_mv |
AT changjingyi effectivenessanddiscussionofventilationdesignwithautomaticrevolvingwindow AT kuanyeander effectivenessanddiscussionofventilationdesignwithautomaticrevolvingwindow AT lanchunching effectivenessanddiscussionofventilationdesignwithautomaticrevolvingwindow AT lihsingju effectivenessanddiscussionofventilationdesignwithautomaticrevolvingwindow AT hsuyukun effectivenessanddiscussionofventilationdesignwithautomaticrevolvingwindow AT chenchihyao effectivenessanddiscussionofventilationdesignwithautomaticrevolvingwindow AT shenenting effectivenessanddiscussionofventilationdesignwithautomaticrevolvingwindow AT chenchihyen effectivenessanddiscussionofventilationdesignwithautomaticrevolvingwindow |
_version_ |
1724297868988121088 |