First Evaluation of a Retinal Imaging Laser Eyewear System Based Low Vision Aid

Mareile Stöhr, Dirk Dekowski, Nikolaos Bechrakis, Joachim Esser, Anja Eckstein, Michael Oeverhaus Department of Ophthalmology, University Hospital Essen, Essen, GermanyCorrespondence: Mareile StöhrDepartment of Ophthalmology, University Hospital Essen, Hufelandstr. 55, Essen 45147,...

Full description

Bibliographic Details
Main Authors: Stöhr M, Dekowski D, Bechrakis N, Esser J, Eckstein A, Oeverhaus M
Format: Article
Language:English
Published: Dove Medical Press 2020-11-01
Series:Clinical Ophthalmology
Subjects:
lva
Online Access:https://www.dovepress.com/first-evaluation-of-a-retinal-imaging-laser-eyewear-system-based-low-v-peer-reviewed-article-OPTH
id doaj-07939e3112bb4448a5df1e0f7485373d
record_format Article
spelling doaj-07939e3112bb4448a5df1e0f7485373d2020-11-29T19:48:46ZengDove Medical PressClinical Ophthalmology1177-54832020-11-01Volume 144115412359793First Evaluation of a Retinal Imaging Laser Eyewear System Based Low Vision AidStöhr MDekowski DBechrakis NEsser JEckstein AOeverhaus MMareile Stöhr, Dirk Dekowski, Nikolaos Bechrakis, Joachim Esser, Anja Eckstein, Michael Oeverhaus Department of Ophthalmology, University Hospital Essen, Essen, GermanyCorrespondence: Mareile StöhrDepartment of Ophthalmology, University Hospital Essen, Hufelandstr. 55, Essen 45147, GermanyTel +49-201-723-2976Fax +49-201-723-6755Email Mareile.stoehr@uk-essen.dePurpose: We conducted this trial to investigate a new wearable laser-eyewear (LEW). Images of an integrated camera are projected to the retina by a RGB-Laser (< 1μW) and MEMS-mirror system. This enables a full-color live video as augmented reality embedded in the field of vision of the wearer. Thin parallel laser beams are projected following the principle of Maxwellian view through the center of the ocular lens to ensure independency of refractive errors. We performed a study with healthy subjects to test this independency.Materials and Methods: LEW was tested in 20 healthy subjects (aged between 21 and 60 years) with hyperopia, myopia, astigmatism and/or presbyopia. Subjects underwent standardized visual acuity (VA) measurements (ETDRS) without any correction, with LEW and with best correction.Results: We found no significant correlation between refraction and VA while using LEW in linear regression (r=0.17). Still, younger participants performed better in terms of VA with the device compared to older participants despite no differences in BCVA (p< 0.01). The achievable VA with LEW was in general reduced compared to uncorrected VA (0.50 vs 0.40 logMAR). Only myopic subjects reached a significantly higher VA using LEW (p< 0.001). Presbyopic subjects showed enhanced near VA (0.25 logMAR) by reading at 15cm with LEW without any further necessary refractive correction. Nearly all patients (80%) showed stereopsis without need for additional adjustments.Conclusion: Our investigation could verify the independence of LEW of refractive errors. Therefore, the technology seems to be especially useful in patients with untreatable corneal conditions, e.g., after corneal burns, to achieve higher VA since the thin laser should penetrate even corneal opacities with less scattering.Keywords: low vision, visual impairment; VI, corneal haze, visual rehabilitation, dystrophy, low vision aid; LVA, Maxwellian view, augmented reality; ARhttps://www.dovepress.com/first-evaluation-of-a-retinal-imaging-laser-eyewear-system-based-low-v-peer-reviewed-article-OPTHlow visionvisual impairmentcorneal hazevisual rehabilitationdystrophylvamaxwellian viewaugmented-reality
collection DOAJ
language English
format Article
sources DOAJ
author Stöhr M
Dekowski D
Bechrakis N
Esser J
Eckstein A
Oeverhaus M
spellingShingle Stöhr M
Dekowski D
Bechrakis N
Esser J
Eckstein A
Oeverhaus M
First Evaluation of a Retinal Imaging Laser Eyewear System Based Low Vision Aid
Clinical Ophthalmology
low vision
visual impairment
corneal haze
visual rehabilitation
dystrophy
lva
maxwellian view
augmented-reality
author_facet Stöhr M
Dekowski D
Bechrakis N
Esser J
Eckstein A
Oeverhaus M
author_sort Stöhr M
title First Evaluation of a Retinal Imaging Laser Eyewear System Based Low Vision Aid
title_short First Evaluation of a Retinal Imaging Laser Eyewear System Based Low Vision Aid
title_full First Evaluation of a Retinal Imaging Laser Eyewear System Based Low Vision Aid
title_fullStr First Evaluation of a Retinal Imaging Laser Eyewear System Based Low Vision Aid
title_full_unstemmed First Evaluation of a Retinal Imaging Laser Eyewear System Based Low Vision Aid
title_sort first evaluation of a retinal imaging laser eyewear system based low vision aid
publisher Dove Medical Press
series Clinical Ophthalmology
issn 1177-5483
publishDate 2020-11-01
description Mareile Stöhr, Dirk Dekowski, Nikolaos Bechrakis, Joachim Esser, Anja Eckstein, Michael Oeverhaus Department of Ophthalmology, University Hospital Essen, Essen, GermanyCorrespondence: Mareile StöhrDepartment of Ophthalmology, University Hospital Essen, Hufelandstr. 55, Essen 45147, GermanyTel +49-201-723-2976Fax +49-201-723-6755Email Mareile.stoehr@uk-essen.dePurpose: We conducted this trial to investigate a new wearable laser-eyewear (LEW). Images of an integrated camera are projected to the retina by a RGB-Laser (< 1μW) and MEMS-mirror system. This enables a full-color live video as augmented reality embedded in the field of vision of the wearer. Thin parallel laser beams are projected following the principle of Maxwellian view through the center of the ocular lens to ensure independency of refractive errors. We performed a study with healthy subjects to test this independency.Materials and Methods: LEW was tested in 20 healthy subjects (aged between 21 and 60 years) with hyperopia, myopia, astigmatism and/or presbyopia. Subjects underwent standardized visual acuity (VA) measurements (ETDRS) without any correction, with LEW and with best correction.Results: We found no significant correlation between refraction and VA while using LEW in linear regression (r=0.17). Still, younger participants performed better in terms of VA with the device compared to older participants despite no differences in BCVA (p< 0.01). The achievable VA with LEW was in general reduced compared to uncorrected VA (0.50 vs 0.40 logMAR). Only myopic subjects reached a significantly higher VA using LEW (p< 0.001). Presbyopic subjects showed enhanced near VA (0.25 logMAR) by reading at 15cm with LEW without any further necessary refractive correction. Nearly all patients (80%) showed stereopsis without need for additional adjustments.Conclusion: Our investigation could verify the independence of LEW of refractive errors. Therefore, the technology seems to be especially useful in patients with untreatable corneal conditions, e.g., after corneal burns, to achieve higher VA since the thin laser should penetrate even corneal opacities with less scattering.Keywords: low vision, visual impairment; VI, corneal haze, visual rehabilitation, dystrophy, low vision aid; LVA, Maxwellian view, augmented reality; AR
topic low vision
visual impairment
corneal haze
visual rehabilitation
dystrophy
lva
maxwellian view
augmented-reality
url https://www.dovepress.com/first-evaluation-of-a-retinal-imaging-laser-eyewear-system-based-low-v-peer-reviewed-article-OPTH
work_keys_str_mv AT stohrm firstevaluationofaretinalimaginglasereyewearsystembasedlowvisionaid
AT dekowskid firstevaluationofaretinalimaginglasereyewearsystembasedlowvisionaid
AT bechrakisn firstevaluationofaretinalimaginglasereyewearsystembasedlowvisionaid
AT esserj firstevaluationofaretinalimaginglasereyewearsystembasedlowvisionaid
AT ecksteina firstevaluationofaretinalimaginglasereyewearsystembasedlowvisionaid
AT oeverhausm firstevaluationofaretinalimaginglasereyewearsystembasedlowvisionaid
_version_ 1724411846729924608