An in Vitro Study to Evaluate the Accuracy of Addition Silicone and Polyether Impression Materials after Different Pouring Time.

Aims: To evaluate the accuracy of two different impression materials and to evaluate the effect of time of pouring on the accuracy of impression. Materials and Methods: Four parallel implant placed in foam arch to obtain study model. Medium body addition silicone and medium body polyether are used....

Full description

Bibliographic Details
Main Authors: Manaf Basil Ahmed, Makdad Najeeb Chakmakchi
Format: Article
Language:Arabic
Published: University of Mosul, College of Dentistry 2016-04-01
Series:Al-Rafidain Dental Journal
Subjects:
Online Access:https://rden.mosuljournals.com/pdf_160862_a62114c2c9c477948caf781b40aa844e.html
id doaj-07b2e2f99b6445e58f8ff6d9fac6e000
record_format Article
spelling doaj-07b2e2f99b6445e58f8ff6d9fac6e0002020-11-25T02:23:01ZaraUniversity of Mosul, College of DentistryAl-Rafidain Dental Journal 1812-12171998-03452016-04-01161101810.33899/rden.2016.160862An in Vitro Study to Evaluate the Accuracy of Addition Silicone and Polyether Impression Materials after Different Pouring Time.Manaf Basil Ahmed Makdad Najeeb ChakmakchiAims: To evaluate the accuracy of two different impression materials and to evaluate the effect of time of pouring on the accuracy of impression. Materials and Methods: Four parallel implant placed in foam arch to obtain study model. Medium body addition silicone and medium body polyether are used. 20 impressions of study model were taken under monophase technique, 10 by addition silicone and 10 by polyether by closed tray technique, half of them were pour after one hour and another half of the impressions were poured after 24 hours by die stone to obtain casts. By using Traveling microscope three linear measurements were measured between 4 implants and comparsime was made between distances on the model and on the casts to assess the dimensional changes of impression materials. Results: Statistical analysis of data by paired sample T-test at (p≤0.05) reveals no significant difference in the accuracy of each material after one and 24 hours and the results analyzed by independent samples T-test reveals no significant difference between materials after one and 24 hours under closed tray technique (dimensional change don’t exceed 1%). Conclusions: The results appeared that there is no difference in the accuracy between addition silicone and polyether and there is no effect of time (1h-24h) on the accuracy of impression, also results showed the high dimensional stability of two materials. https://rden.mosuljournals.com/pdf_160862_a62114c2c9c477948caf781b40aa844e.html: elastomeric impression materialaccuracy of impressiontechniques for implanttime of pouring
collection DOAJ
language Arabic
format Article
sources DOAJ
author Manaf Basil Ahmed
Makdad Najeeb Chakmakchi
spellingShingle Manaf Basil Ahmed
Makdad Najeeb Chakmakchi
An in Vitro Study to Evaluate the Accuracy of Addition Silicone and Polyether Impression Materials after Different Pouring Time.
Al-Rafidain Dental Journal
: elastomeric impression material
accuracy of impression
techniques for implant
time of pouring
author_facet Manaf Basil Ahmed
Makdad Najeeb Chakmakchi
author_sort Manaf Basil Ahmed
title An in Vitro Study to Evaluate the Accuracy of Addition Silicone and Polyether Impression Materials after Different Pouring Time.
title_short An in Vitro Study to Evaluate the Accuracy of Addition Silicone and Polyether Impression Materials after Different Pouring Time.
title_full An in Vitro Study to Evaluate the Accuracy of Addition Silicone and Polyether Impression Materials after Different Pouring Time.
title_fullStr An in Vitro Study to Evaluate the Accuracy of Addition Silicone and Polyether Impression Materials after Different Pouring Time.
title_full_unstemmed An in Vitro Study to Evaluate the Accuracy of Addition Silicone and Polyether Impression Materials after Different Pouring Time.
title_sort in vitro study to evaluate the accuracy of addition silicone and polyether impression materials after different pouring time.
publisher University of Mosul, College of Dentistry
series Al-Rafidain Dental Journal
issn 1812-1217
1998-0345
publishDate 2016-04-01
description Aims: To evaluate the accuracy of two different impression materials and to evaluate the effect of time of pouring on the accuracy of impression. Materials and Methods: Four parallel implant placed in foam arch to obtain study model. Medium body addition silicone and medium body polyether are used. 20 impressions of study model were taken under monophase technique, 10 by addition silicone and 10 by polyether by closed tray technique, half of them were pour after one hour and another half of the impressions were poured after 24 hours by die stone to obtain casts. By using Traveling microscope three linear measurements were measured between 4 implants and comparsime was made between distances on the model and on the casts to assess the dimensional changes of impression materials. Results: Statistical analysis of data by paired sample T-test at (p≤0.05) reveals no significant difference in the accuracy of each material after one and 24 hours and the results analyzed by independent samples T-test reveals no significant difference between materials after one and 24 hours under closed tray technique (dimensional change don’t exceed 1%). Conclusions: The results appeared that there is no difference in the accuracy between addition silicone and polyether and there is no effect of time (1h-24h) on the accuracy of impression, also results showed the high dimensional stability of two materials.
topic : elastomeric impression material
accuracy of impression
techniques for implant
time of pouring
url https://rden.mosuljournals.com/pdf_160862_a62114c2c9c477948caf781b40aa844e.html
work_keys_str_mv AT manafbasilahmed aninvitrostudytoevaluatetheaccuracyofadditionsiliconeandpolyetherimpressionmaterialsafterdifferentpouringtime
AT makdadnajeebchakmakchi aninvitrostudytoevaluatetheaccuracyofadditionsiliconeandpolyetherimpressionmaterialsafterdifferentpouringtime
AT manafbasilahmed invitrostudytoevaluatetheaccuracyofadditionsiliconeandpolyetherimpressionmaterialsafterdifferentpouringtime
AT makdadnajeebchakmakchi invitrostudytoevaluatetheaccuracyofadditionsiliconeandpolyetherimpressionmaterialsafterdifferentpouringtime
_version_ 1724860376260018176