A Comparative Retrospective Analysis of Tension Band Wiring and 3.5 mm Precontoured Plate Used for Fixation of Chevron Osteotomy in Type C Distal Humerus Fractures
Introduction Complex distal humerus fractures are rare and difficult to treat and traditionally requires an open reduction and internal fixation via a transolecranon approach. However, controversy remains regarding the better method of fixation of the chevron osteotomy. The purpose of the present st...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Thieme Medical and Scientific Publishers Pvt. Ltd.
2020-12-01
|
Series: | International Journal of Recent Surgical and Medical Sciences |
Subjects: | |
Online Access: | http://www.thieme-connect.de/DOI/DOI?10.1055/s-0040-1721540 |
id |
doaj-07bc73d8eebe4507847e5e03b35a7301 |
---|---|
record_format |
Article |
spelling |
doaj-07bc73d8eebe4507847e5e03b35a73012021-04-02T17:48:10ZengThieme Medical and Scientific Publishers Pvt. Ltd.International Journal of Recent Surgical and Medical Sciences2455-74202455-09492020-12-01602535910.1055/s-0040-1721540A Comparative Retrospective Analysis of Tension Band Wiring and 3.5 mm Precontoured Plate Used for Fixation of Chevron Osteotomy in Type C Distal Humerus FracturesMayur Nayak0Rahul Yadav1Sahil Batra2Vijay Sharma3Kamran Farooque4Siddhartha Maredupaka5Department of Orthopaedics, Jay Prakash Narayan Apex Trauma Center, All India Institute of Medical Sciences, New Delhi, IndiaDepartment of Orthopaedics, All India Institute of Medical Sciences, New Delhi, IndiaDepartment of Orthopaedics, All India Institute of Medical Sciences, New Delhi, IndiaDepartment of Orthopaedics, Jay Prakash Narayan Apex Trauma Center, All India Institute of Medical Sciences, New Delhi, IndiaDepartment of Orthopaedics, Jay Prakash Narayan Apex Trauma Center, All India Institute of Medical Sciences, New Delhi, IndiaDepartment of Orthopaedics, All India Institute of Medical Sciences, New Delhi, IndiaIntroduction Complex distal humerus fractures are rare and difficult to treat and traditionally requires an open reduction and internal fixation via a transolecranon approach. However, controversy remains regarding the better method of fixation of the chevron osteotomy. The purpose of the present study was to compare the clinical efficacy of tension band wiring (TBW) and 3.5 mm precontoured plate in treating the chevron osteotomy. Materials and Methods A consecutive series of 49 patients who required olecranon osteotomy for type C distal humerus fractures were identified and grouped according to the construct used. Clinic–radiological evaluation was done at 3 months, 6 months, 1 year, and 2 years. A total of 34 males and 15 females with a mean age of 36.9 ± 12.64 years (18–62 years) were included in the study. Surgical duration, range of motion, Mayo elbow performance score (MEPS), and complications were noted at the follow-up. Results The mean range of motion was initially lower in the plate group (105 degrees ± 9.9 in plate, 107 degrees ± 9.15 in TBW) that subsequently increased at 6 months. The forearm rotation was similar in both the groups. The mean MEPS was found to be higher in the plate group at 2 years (81.83 ± 5.85 in plate, 77.76 ± 8.02 in TBW). A significantly higher rate of complications, that is, nonunion (p = 0.03), loss of reduction (p = 0.03), and revision (p = 0.04) was observed in the TBW group. However, other complications such as symptomatic hardware, wound complication, and removal of hardware were found to be higher in the plate group. Conclusion Both TBW and 3.5 mm precontoured plate provide comparable functional outcomes; however, the complication rate in terms of nonunion, loss of reduction, and revision is seen in the TBW, whereas wound complication and symptomatic hardware are more commonly seen in the plate.http://www.thieme-connect.de/DOI/DOI?10.1055/s-0040-1721540distal humerus fracturesolecranon platechevron osteotomytension band wiringnonunion |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Mayur Nayak Rahul Yadav Sahil Batra Vijay Sharma Kamran Farooque Siddhartha Maredupaka |
spellingShingle |
Mayur Nayak Rahul Yadav Sahil Batra Vijay Sharma Kamran Farooque Siddhartha Maredupaka A Comparative Retrospective Analysis of Tension Band Wiring and 3.5 mm Precontoured Plate Used for Fixation of Chevron Osteotomy in Type C Distal Humerus Fractures International Journal of Recent Surgical and Medical Sciences distal humerus fractures olecranon plate chevron osteotomy tension band wiring nonunion |
author_facet |
Mayur Nayak Rahul Yadav Sahil Batra Vijay Sharma Kamran Farooque Siddhartha Maredupaka |
author_sort |
Mayur Nayak |
title |
A Comparative Retrospective Analysis of Tension Band Wiring and 3.5 mm Precontoured Plate Used for Fixation of Chevron Osteotomy in Type C Distal Humerus Fractures |
title_short |
A Comparative Retrospective Analysis of Tension Band Wiring and 3.5 mm Precontoured Plate Used for Fixation of Chevron Osteotomy in Type C Distal Humerus Fractures |
title_full |
A Comparative Retrospective Analysis of Tension Band Wiring and 3.5 mm Precontoured Plate Used for Fixation of Chevron Osteotomy in Type C Distal Humerus Fractures |
title_fullStr |
A Comparative Retrospective Analysis of Tension Band Wiring and 3.5 mm Precontoured Plate Used for Fixation of Chevron Osteotomy in Type C Distal Humerus Fractures |
title_full_unstemmed |
A Comparative Retrospective Analysis of Tension Band Wiring and 3.5 mm Precontoured Plate Used for Fixation of Chevron Osteotomy in Type C Distal Humerus Fractures |
title_sort |
comparative retrospective analysis of tension band wiring and 3.5 mm precontoured plate used for fixation of chevron osteotomy in type c distal humerus fractures |
publisher |
Thieme Medical and Scientific Publishers Pvt. Ltd. |
series |
International Journal of Recent Surgical and Medical Sciences |
issn |
2455-7420 2455-0949 |
publishDate |
2020-12-01 |
description |
Introduction Complex distal humerus fractures are rare and difficult to treat and traditionally requires an open reduction and internal fixation via a transolecranon approach. However, controversy remains regarding the better method of fixation of the chevron osteotomy. The purpose of the present study was to compare the clinical efficacy of tension band wiring (TBW) and 3.5 mm precontoured plate in treating the chevron osteotomy.
Materials and Methods A consecutive series of 49 patients who required olecranon osteotomy for type C distal humerus fractures were identified and grouped according to the construct used. Clinic–radiological evaluation was done at 3 months, 6 months, 1 year, and 2 years. A total of 34 males and 15 females with a mean age of 36.9 ± 12.64 years (18–62 years) were included in the study. Surgical duration, range of motion, Mayo elbow performance score (MEPS), and complications were noted at the follow-up.
Results The mean range of motion was initially lower in the plate group (105 degrees ± 9.9 in plate, 107 degrees ± 9.15 in TBW) that subsequently increased at 6 months. The forearm rotation was similar in both the groups. The mean MEPS was found to be higher in the plate group at 2 years (81.83 ± 5.85 in plate, 77.76 ± 8.02 in TBW). A significantly higher rate of complications, that is, nonunion (p = 0.03), loss of reduction (p = 0.03), and revision (p = 0.04) was observed in the TBW group. However, other complications such as symptomatic hardware, wound complication, and removal of hardware were found to be higher in the plate group.
Conclusion Both TBW and 3.5 mm precontoured plate provide comparable functional outcomes; however, the complication rate in terms of nonunion, loss of reduction, and revision is seen in the TBW, whereas wound complication and symptomatic hardware are more commonly seen in the plate. |
topic |
distal humerus fractures olecranon plate chevron osteotomy tension band wiring nonunion |
url |
http://www.thieme-connect.de/DOI/DOI?10.1055/s-0040-1721540 |
work_keys_str_mv |
AT mayurnayak acomparativeretrospectiveanalysisoftensionbandwiringand35mmprecontouredplateusedforfixationofchevronosteotomyintypecdistalhumerusfractures AT rahulyadav acomparativeretrospectiveanalysisoftensionbandwiringand35mmprecontouredplateusedforfixationofchevronosteotomyintypecdistalhumerusfractures AT sahilbatra acomparativeretrospectiveanalysisoftensionbandwiringand35mmprecontouredplateusedforfixationofchevronosteotomyintypecdistalhumerusfractures AT vijaysharma acomparativeretrospectiveanalysisoftensionbandwiringand35mmprecontouredplateusedforfixationofchevronosteotomyintypecdistalhumerusfractures AT kamranfarooque acomparativeretrospectiveanalysisoftensionbandwiringand35mmprecontouredplateusedforfixationofchevronosteotomyintypecdistalhumerusfractures AT siddharthamaredupaka acomparativeretrospectiveanalysisoftensionbandwiringand35mmprecontouredplateusedforfixationofchevronosteotomyintypecdistalhumerusfractures AT mayurnayak comparativeretrospectiveanalysisoftensionbandwiringand35mmprecontouredplateusedforfixationofchevronosteotomyintypecdistalhumerusfractures AT rahulyadav comparativeretrospectiveanalysisoftensionbandwiringand35mmprecontouredplateusedforfixationofchevronosteotomyintypecdistalhumerusfractures AT sahilbatra comparativeretrospectiveanalysisoftensionbandwiringand35mmprecontouredplateusedforfixationofchevronosteotomyintypecdistalhumerusfractures AT vijaysharma comparativeretrospectiveanalysisoftensionbandwiringand35mmprecontouredplateusedforfixationofchevronosteotomyintypecdistalhumerusfractures AT kamranfarooque comparativeretrospectiveanalysisoftensionbandwiringand35mmprecontouredplateusedforfixationofchevronosteotomyintypecdistalhumerusfractures AT siddharthamaredupaka comparativeretrospectiveanalysisoftensionbandwiringand35mmprecontouredplateusedforfixationofchevronosteotomyintypecdistalhumerusfractures |
_version_ |
1721553317434228736 |