A Patient Specific Biomechanical Analysis of Custom Root Analogue Implant Designs on Alveolar Bone Stress: A Finite Element Study
Objectives. The aim of this study was to analyse by means of FEA the influence of 5 custom RAI designs on stress distribution of peri-implant bone and to evaluate the impact on microdisplacement for a specific patient case. Materials and Methods. A 3D surface model of a RAI for the upper right canin...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2016-01-01
|
Series: | International Journal of Dentistry |
Online Access: | http://dx.doi.org/10.1155/2016/8242535 |
id |
doaj-08e02eb30aaa416db6943818a8c56d69 |
---|---|
record_format |
Article |
spelling |
doaj-08e02eb30aaa416db6943818a8c56d692020-11-25T00:01:43ZengHindawi LimitedInternational Journal of Dentistry1687-87281687-87362016-01-01201610.1155/2016/82425358242535A Patient Specific Biomechanical Analysis of Custom Root Analogue Implant Designs on Alveolar Bone Stress: A Finite Element StudyDavid Anssari Moin0Bassam Hassan1Daniel Wismeijer2Department of Oral Function and Restorative Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), Research Institute MOVE, 1081 LA Amsterdam, NetherlandsDepartment of Oral Function and Restorative Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), Research Institute MOVE, 1081 LA Amsterdam, NetherlandsDepartment of Oral Function and Restorative Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), Research Institute MOVE, 1081 LA Amsterdam, NetherlandsObjectives. The aim of this study was to analyse by means of FEA the influence of 5 custom RAI designs on stress distribution of peri-implant bone and to evaluate the impact on microdisplacement for a specific patient case. Materials and Methods. A 3D surface model of a RAI for the upper right canine was constructed from the cone beam computed tomography data of one patient. Subsequently, five (targeted) press-fit design modification FE models with five congruent bone models were designed: “Standard,” “Prism,” “Fins,” “Plug,” and “Bulbs,” respectively. Preprocessor software was applied to mesh the models. Two loads were applied: an oblique force (300 N) and a vertical force (150 N). Analysis was performed to evaluate stress distributions and deformed contact separation at the peri-implant region. Results. The lowest von Mises stress levels were numerically observed for the Plug design. The lowest levels of contact separation were measured in the Fins model followed by the Bulbs design. Conclusions. Within the limitations of the applied methodology, adding targeted press-fit geometry to the RAI standard design will have a positive effect on stress distribution, lower concentration of bone stress, and will provide a better primary stability for this patient specific case.http://dx.doi.org/10.1155/2016/8242535 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
David Anssari Moin Bassam Hassan Daniel Wismeijer |
spellingShingle |
David Anssari Moin Bassam Hassan Daniel Wismeijer A Patient Specific Biomechanical Analysis of Custom Root Analogue Implant Designs on Alveolar Bone Stress: A Finite Element Study International Journal of Dentistry |
author_facet |
David Anssari Moin Bassam Hassan Daniel Wismeijer |
author_sort |
David Anssari Moin |
title |
A Patient Specific Biomechanical Analysis of Custom Root Analogue Implant Designs on Alveolar Bone Stress: A Finite Element Study |
title_short |
A Patient Specific Biomechanical Analysis of Custom Root Analogue Implant Designs on Alveolar Bone Stress: A Finite Element Study |
title_full |
A Patient Specific Biomechanical Analysis of Custom Root Analogue Implant Designs on Alveolar Bone Stress: A Finite Element Study |
title_fullStr |
A Patient Specific Biomechanical Analysis of Custom Root Analogue Implant Designs on Alveolar Bone Stress: A Finite Element Study |
title_full_unstemmed |
A Patient Specific Biomechanical Analysis of Custom Root Analogue Implant Designs on Alveolar Bone Stress: A Finite Element Study |
title_sort |
patient specific biomechanical analysis of custom root analogue implant designs on alveolar bone stress: a finite element study |
publisher |
Hindawi Limited |
series |
International Journal of Dentistry |
issn |
1687-8728 1687-8736 |
publishDate |
2016-01-01 |
description |
Objectives. The aim of this study was to analyse by means of FEA the influence of 5 custom RAI designs on stress distribution of peri-implant bone and to evaluate the impact on microdisplacement for a specific patient case. Materials and Methods. A 3D surface model of a RAI for the upper right canine was constructed from the cone beam computed tomography data of one patient. Subsequently, five (targeted) press-fit design modification FE models with five congruent bone models were designed: “Standard,” “Prism,” “Fins,” “Plug,” and “Bulbs,” respectively. Preprocessor software was applied to mesh the models. Two loads were applied: an oblique force (300 N) and a vertical force (150 N). Analysis was performed to evaluate stress distributions and deformed contact separation at the peri-implant region. Results. The lowest von Mises stress levels were numerically observed for the Plug design. The lowest levels of contact separation were measured in the Fins model followed by the Bulbs design. Conclusions. Within the limitations of the applied methodology, adding targeted press-fit geometry to the RAI standard design will have a positive effect on stress distribution, lower concentration of bone stress, and will provide a better primary stability for this patient specific case. |
url |
http://dx.doi.org/10.1155/2016/8242535 |
work_keys_str_mv |
AT davidanssarimoin apatientspecificbiomechanicalanalysisofcustomrootanalogueimplantdesignsonalveolarbonestressafiniteelementstudy AT bassamhassan apatientspecificbiomechanicalanalysisofcustomrootanalogueimplantdesignsonalveolarbonestressafiniteelementstudy AT danielwismeijer apatientspecificbiomechanicalanalysisofcustomrootanalogueimplantdesignsonalveolarbonestressafiniteelementstudy AT davidanssarimoin patientspecificbiomechanicalanalysisofcustomrootanalogueimplantdesignsonalveolarbonestressafiniteelementstudy AT bassamhassan patientspecificbiomechanicalanalysisofcustomrootanalogueimplantdesignsonalveolarbonestressafiniteelementstudy AT danielwismeijer patientspecificbiomechanicalanalysisofcustomrootanalogueimplantdesignsonalveolarbonestressafiniteelementstudy |
_version_ |
1725440756423852032 |