Evaluation of Bunch Length by Measuring Coherent Synchrotron Radiation with a Narrow-Band Detector at LEBRA

This study presents a novel technology to measure electron bunch length with a high time resolution by measuring coherent synchrotron radiation using a narrow-band detector at Laboratory for Electron Beam Research and Application (LEBRA)—an S-band linear accelerator facility for free-electron lasers...

Full description

Bibliographic Details
Main Authors: Takeshi Sakai, Ken Hayakawa, Toshinari Tanaka, Yasushi Hayakawa, Kyoko Nogami, Norihiro Sei
Format: Article
Language:English
Published: MDPI AG 2020-05-01
Series:Condensed Matter
Subjects:
FEL
Online Access:https://www.mdpi.com/2410-3896/5/2/34
id doaj-095686a782d345bfa3317a0ee92b6cc0
record_format Article
spelling doaj-095686a782d345bfa3317a0ee92b6cc02020-11-25T02:11:39ZengMDPI AGCondensed Matter2410-38962020-05-015343410.3390/condmat5020034Evaluation of Bunch Length by Measuring Coherent Synchrotron Radiation with a Narrow-Band Detector at LEBRATakeshi Sakai0Ken Hayakawa1Toshinari Tanaka2Yasushi Hayakawa3Kyoko Nogami4Norihiro Sei5Laboratory for Electron Beam Research and Application, Nihon University, 7-24-1 Narashinodai, Funabashi 274-8501, JapanLaboratory for Electron Beam Research and Application, Nihon University, 7-24-1 Narashinodai, Funabashi 274-8501, JapanLaboratory for Electron Beam Research and Application, Nihon University, 7-24-1 Narashinodai, Funabashi 274-8501, JapanLaboratory for Electron Beam Research and Application, Nihon University, 7-24-1 Narashinodai, Funabashi 274-8501, JapanLaboratory for Electron Beam Research and Application, Nihon University, 7-24-1 Narashinodai, Funabashi 274-8501, JapanResearch Institute of Instrumentation Frontier, National Institute of Advanced Industrial Science and Technology, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568, JapanThis study presents a novel technology to measure electron bunch length with a high time resolution by measuring coherent synchrotron radiation using a narrow-band detector at Laboratory for Electron Beam Research and Application (LEBRA)—an S-band linear accelerator facility for free-electron lasers. The form factor was observed to decrease exponentially with charge—in concordance with the relationship between the intensity of the coherent synchrotron radiation and the magnitude of electron bunch charge—in the region in which the effect of electron bunch charge on bunch length is negligible. The calculated root-mean-square bunch length was observed to agree well with the value determined from the spectral shape obtained. The aforementioned results are expected to be useful in real-time observation of small changes in electron bunches in advanced accelerators.https://www.mdpi.com/2410-3896/5/2/34coherent synchrotron radiationbunch lengthFELlinacterahertz
collection DOAJ
language English
format Article
sources DOAJ
author Takeshi Sakai
Ken Hayakawa
Toshinari Tanaka
Yasushi Hayakawa
Kyoko Nogami
Norihiro Sei
spellingShingle Takeshi Sakai
Ken Hayakawa
Toshinari Tanaka
Yasushi Hayakawa
Kyoko Nogami
Norihiro Sei
Evaluation of Bunch Length by Measuring Coherent Synchrotron Radiation with a Narrow-Band Detector at LEBRA
Condensed Matter
coherent synchrotron radiation
bunch length
FEL
linac
terahertz
author_facet Takeshi Sakai
Ken Hayakawa
Toshinari Tanaka
Yasushi Hayakawa
Kyoko Nogami
Norihiro Sei
author_sort Takeshi Sakai
title Evaluation of Bunch Length by Measuring Coherent Synchrotron Radiation with a Narrow-Band Detector at LEBRA
title_short Evaluation of Bunch Length by Measuring Coherent Synchrotron Radiation with a Narrow-Band Detector at LEBRA
title_full Evaluation of Bunch Length by Measuring Coherent Synchrotron Radiation with a Narrow-Band Detector at LEBRA
title_fullStr Evaluation of Bunch Length by Measuring Coherent Synchrotron Radiation with a Narrow-Band Detector at LEBRA
title_full_unstemmed Evaluation of Bunch Length by Measuring Coherent Synchrotron Radiation with a Narrow-Band Detector at LEBRA
title_sort evaluation of bunch length by measuring coherent synchrotron radiation with a narrow-band detector at lebra
publisher MDPI AG
series Condensed Matter
issn 2410-3896
publishDate 2020-05-01
description This study presents a novel technology to measure electron bunch length with a high time resolution by measuring coherent synchrotron radiation using a narrow-band detector at Laboratory for Electron Beam Research and Application (LEBRA)—an S-band linear accelerator facility for free-electron lasers. The form factor was observed to decrease exponentially with charge—in concordance with the relationship between the intensity of the coherent synchrotron radiation and the magnitude of electron bunch charge—in the region in which the effect of electron bunch charge on bunch length is negligible. The calculated root-mean-square bunch length was observed to agree well with the value determined from the spectral shape obtained. The aforementioned results are expected to be useful in real-time observation of small changes in electron bunches in advanced accelerators.
topic coherent synchrotron radiation
bunch length
FEL
linac
terahertz
url https://www.mdpi.com/2410-3896/5/2/34
work_keys_str_mv AT takeshisakai evaluationofbunchlengthbymeasuringcoherentsynchrotronradiationwithanarrowbanddetectoratlebra
AT kenhayakawa evaluationofbunchlengthbymeasuringcoherentsynchrotronradiationwithanarrowbanddetectoratlebra
AT toshinaritanaka evaluationofbunchlengthbymeasuringcoherentsynchrotronradiationwithanarrowbanddetectoratlebra
AT yasushihayakawa evaluationofbunchlengthbymeasuringcoherentsynchrotronradiationwithanarrowbanddetectoratlebra
AT kyokonogami evaluationofbunchlengthbymeasuringcoherentsynchrotronradiationwithanarrowbanddetectoratlebra
AT norihirosei evaluationofbunchlengthbymeasuringcoherentsynchrotronradiationwithanarrowbanddetectoratlebra
_version_ 1724913443966812160