Lead-I ECG for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: A systematic review and economic evaluation.

<h4>Background</h4>Atrial fibrillation (AF) is the most common type of cardiac arrhythmia and is associated with increased risk of stroke and congestive heart failure. Lead-I electrocardiogram (ECG) devices are handheld instruments that can detect AF at a single-time point.<h4>Purp...

Full description

Bibliographic Details
Main Authors: Rui Duarte, Angela Stainthorpe, James Mahon, Janette Greenhalgh, Marty Richardson, Sarah Nevitt, Eleanor Kotas, Angela Boland, Howard Thom, Tom Marshall, Mark Hall, Yemisi Takwoingi
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2019-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/books/NBK552418
id doaj-09df79a709174f64a6ee0104926fd8ed
record_format Article
spelling doaj-09df79a709174f64a6ee0104926fd8ed2021-03-04T12:43:17ZengPublic Library of Science (PLoS)PLoS ONE1932-62032019-01-011412e022667110.1371/journal.pone.0226671Lead-I ECG for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: A systematic review and economic evaluation.Rui DuarteAngela StainthorpeJames MahonJanette GreenhalghMarty RichardsonSarah NevittEleanor KotasAngela BolandHoward ThomTom MarshallMark HallYemisi Takwoingi<h4>Background</h4>Atrial fibrillation (AF) is the most common type of cardiac arrhythmia and is associated with increased risk of stroke and congestive heart failure. Lead-I electrocardiogram (ECG) devices are handheld instruments that can detect AF at a single-time point.<h4>Purpose</h4>To assess the diagnostic test accuracy, clinical impact and cost effectiveness of single-time point lead-I ECG devices compared with manual pulse palpation (MPP) followed by a 12-lead ECG for the detection of AF in symptomatic primary care patients with an irregular pulse.<h4>Methods</h4>Electronic databases (MEDLINE, MEDLINE Epub Ahead of Print and MEDLINE In-Process, EMBASE, PubMed and Cochrane Databases of Systematic Reviews, Cochrane Central Database of Controlled Trials, Database of Abstracts of Reviews of Effects, Health Technology Assessment Database) were searched to March 2018. Two reviewers screened the search results, extracted data and assessed study quality. Summary estimates of diagnostic accuracy were calculated using bivariate models. Cost-effectiveness was evaluated using an economic model consisting of a decision tree and two cohort Markov models.<h4>Results</h4>Diagnostic accuracy The diagnostic accuracy (13 publications reporting on nine studies) and clinical impact (24 publications reporting on 19 studies) results are derived from an asymptomatic population (used as a proxy for people with signs or symptoms of AF). The summary sensitivity of lead-I ECG devices was 93.9% (95% confidence interval [CI]: 86.2% to 97.4%) and summary specificity was 96.5% (95% CI: 90.4% to 98.8%). Cost effectiveness The de novo economic model yielded incremental cost effectiveness ratios (ICERs) per quality adjusted life year (QALY) gained. The results of the pairwise analysis show that all lead-I ECG devices generate ICERs per QALY gained below the £20,000-£30,000 threshold. Kardia Mobile is the most cost effective option in a full incremental analysis. Lead-I ECG tests may identify more AF cases than the standard diagnostic pathway. This comes at a higher cost but with greater patient benefit in terms of mortality and quality of life.<h4>Limitations</h4>No published data evaluating the diagnostic accuracy, clinical impact or cost effectiveness of lead-I ECG devices for the target population are available.<h4>Conclusions</h4>The use of single-time point lead-I ECG devices in primary care for the detection of AF in people with signs or symptoms of AF and an irregular pulse appears to be a cost effective use of NHS resources compared with MPP followed by a 12-lead ECG, given the assumptions used in the base case model.<h4>Registration</h4>The protocol for this review is registered on PROSPERO as CRD42018090375.http://europepmc.org/books/NBK552418
collection DOAJ
language English
format Article
sources DOAJ
author Rui Duarte
Angela Stainthorpe
James Mahon
Janette Greenhalgh
Marty Richardson
Sarah Nevitt
Eleanor Kotas
Angela Boland
Howard Thom
Tom Marshall
Mark Hall
Yemisi Takwoingi
spellingShingle Rui Duarte
Angela Stainthorpe
James Mahon
Janette Greenhalgh
Marty Richardson
Sarah Nevitt
Eleanor Kotas
Angela Boland
Howard Thom
Tom Marshall
Mark Hall
Yemisi Takwoingi
Lead-I ECG for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: A systematic review and economic evaluation.
PLoS ONE
author_facet Rui Duarte
Angela Stainthorpe
James Mahon
Janette Greenhalgh
Marty Richardson
Sarah Nevitt
Eleanor Kotas
Angela Boland
Howard Thom
Tom Marshall
Mark Hall
Yemisi Takwoingi
author_sort Rui Duarte
title Lead-I ECG for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: A systematic review and economic evaluation.
title_short Lead-I ECG for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: A systematic review and economic evaluation.
title_full Lead-I ECG for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: A systematic review and economic evaluation.
title_fullStr Lead-I ECG for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: A systematic review and economic evaluation.
title_full_unstemmed Lead-I ECG for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: A systematic review and economic evaluation.
title_sort lead-i ecg for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: a systematic review and economic evaluation.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2019-01-01
description <h4>Background</h4>Atrial fibrillation (AF) is the most common type of cardiac arrhythmia and is associated with increased risk of stroke and congestive heart failure. Lead-I electrocardiogram (ECG) devices are handheld instruments that can detect AF at a single-time point.<h4>Purpose</h4>To assess the diagnostic test accuracy, clinical impact and cost effectiveness of single-time point lead-I ECG devices compared with manual pulse palpation (MPP) followed by a 12-lead ECG for the detection of AF in symptomatic primary care patients with an irregular pulse.<h4>Methods</h4>Electronic databases (MEDLINE, MEDLINE Epub Ahead of Print and MEDLINE In-Process, EMBASE, PubMed and Cochrane Databases of Systematic Reviews, Cochrane Central Database of Controlled Trials, Database of Abstracts of Reviews of Effects, Health Technology Assessment Database) were searched to March 2018. Two reviewers screened the search results, extracted data and assessed study quality. Summary estimates of diagnostic accuracy were calculated using bivariate models. Cost-effectiveness was evaluated using an economic model consisting of a decision tree and two cohort Markov models.<h4>Results</h4>Diagnostic accuracy The diagnostic accuracy (13 publications reporting on nine studies) and clinical impact (24 publications reporting on 19 studies) results are derived from an asymptomatic population (used as a proxy for people with signs or symptoms of AF). The summary sensitivity of lead-I ECG devices was 93.9% (95% confidence interval [CI]: 86.2% to 97.4%) and summary specificity was 96.5% (95% CI: 90.4% to 98.8%). Cost effectiveness The de novo economic model yielded incremental cost effectiveness ratios (ICERs) per quality adjusted life year (QALY) gained. The results of the pairwise analysis show that all lead-I ECG devices generate ICERs per QALY gained below the £20,000-£30,000 threshold. Kardia Mobile is the most cost effective option in a full incremental analysis. Lead-I ECG tests may identify more AF cases than the standard diagnostic pathway. This comes at a higher cost but with greater patient benefit in terms of mortality and quality of life.<h4>Limitations</h4>No published data evaluating the diagnostic accuracy, clinical impact or cost effectiveness of lead-I ECG devices for the target population are available.<h4>Conclusions</h4>The use of single-time point lead-I ECG devices in primary care for the detection of AF in people with signs or symptoms of AF and an irregular pulse appears to be a cost effective use of NHS resources compared with MPP followed by a 12-lead ECG, given the assumptions used in the base case model.<h4>Registration</h4>The protocol for this review is registered on PROSPERO as CRD42018090375.
url http://europepmc.org/books/NBK552418
work_keys_str_mv AT ruiduarte leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT angelastainthorpe leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT jamesmahon leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT janettegreenhalgh leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT martyrichardson leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT sarahnevitt leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT eleanorkotas leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT angelaboland leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT howardthom leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT tommarshall leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT markhall leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
AT yemisitakwoingi leadiecgfordetectingatrialfibrillationinpatientsattendingprimarycarewithanirregularpulseusingsingletimepointtestingasystematicreviewandeconomicevaluation
_version_ 1714801747797475328