Surgical outcomes with high and low pulse energy femtosecond laser systems for cataract surgery

Abstract Currently, there is no clear consensus in cataract surgery if low compared to high energy femto-lasers may enable better capsulotomy quality and induce lower inflammatory response. Therefore, the aim of this study was to compare the intra-operative outcomes achieved with high and low pulse...

Full description

Bibliographic Details
Main Authors: Hung-Yuan Lin, Ya-Jung Chuang, Pi-Jung Lin
Format: Article
Language:English
Published: Nature Publishing Group 2021-05-01
Series:Scientific Reports
Online Access:https://doi.org/10.1038/s41598-021-89046-1
id doaj-0aec6bfd778c43c8a4ab77509cb2d8e8
record_format Article
spelling doaj-0aec6bfd778c43c8a4ab77509cb2d8e82021-05-09T11:33:02ZengNature Publishing GroupScientific Reports2045-23222021-05-011111810.1038/s41598-021-89046-1Surgical outcomes with high and low pulse energy femtosecond laser systems for cataract surgeryHung-Yuan Lin0Ya-Jung Chuang1Pi-Jung Lin2Universal Eye CenterUniversal Eye CenterUniversal Eye CenterAbstract Currently, there is no clear consensus in cataract surgery if low compared to high energy femto-lasers may enable better capsulotomy quality and induce lower inflammatory response. Therefore, the aim of this study was to compare the intra-operative outcomes achieved with high and low pulse energy femtosecond laser systems for cataract surgery. The charts of 200 eyes of 200 patients aged 68.3 ± 10.3 years who had undergone femtosecond laser-assisted cataract surgery using either group 1 high pulse energy: LenSx (Alcon Laboratories) (N = 100) or group 2 low pulse energy: FEMTO LDV Z8 (Ziemer) (N = 100) laser were reviewed retrospectively. Integrity of anterior capsulotomy, classified as (1) complete (free-floating or with minor microadhesions), (2) incomplete and (3) with capsular tears, intraoperative completeness of the clear corneal incisions (CCI, main incision and side port), incidences of intraoperative miosis and incidence of subconjunctival hemorrhage were evaluated and compared between the two groups. The proportion of complete capsulotomies was significantly higher in the group 2 than the group 1 (100% vs 94%; p = 0.03). The incidences of intraoperative miosis (0% vs 19%) and subconjunctival hemorrhage (1% vs 63%) were significantly lower in the group 2 than the group 1 (p < 0.001). Completeness of the main incision was comparable (97% vs 95%; p = 0.721) between the two groups. Although not statistically significant, the completeness of side-port incision was slightly better in the group 2 than the group 1 (91% vs 86%). Low energy laser system performed significantly better in terms of completeness of capsulotomy, intraoperative miosis and sub-conjunctival hemorrhage, compared with high energy laser; the CCI outcomes were comparable.https://doi.org/10.1038/s41598-021-89046-1
collection DOAJ
language English
format Article
sources DOAJ
author Hung-Yuan Lin
Ya-Jung Chuang
Pi-Jung Lin
spellingShingle Hung-Yuan Lin
Ya-Jung Chuang
Pi-Jung Lin
Surgical outcomes with high and low pulse energy femtosecond laser systems for cataract surgery
Scientific Reports
author_facet Hung-Yuan Lin
Ya-Jung Chuang
Pi-Jung Lin
author_sort Hung-Yuan Lin
title Surgical outcomes with high and low pulse energy femtosecond laser systems for cataract surgery
title_short Surgical outcomes with high and low pulse energy femtosecond laser systems for cataract surgery
title_full Surgical outcomes with high and low pulse energy femtosecond laser systems for cataract surgery
title_fullStr Surgical outcomes with high and low pulse energy femtosecond laser systems for cataract surgery
title_full_unstemmed Surgical outcomes with high and low pulse energy femtosecond laser systems for cataract surgery
title_sort surgical outcomes with high and low pulse energy femtosecond laser systems for cataract surgery
publisher Nature Publishing Group
series Scientific Reports
issn 2045-2322
publishDate 2021-05-01
description Abstract Currently, there is no clear consensus in cataract surgery if low compared to high energy femto-lasers may enable better capsulotomy quality and induce lower inflammatory response. Therefore, the aim of this study was to compare the intra-operative outcomes achieved with high and low pulse energy femtosecond laser systems for cataract surgery. The charts of 200 eyes of 200 patients aged 68.3 ± 10.3 years who had undergone femtosecond laser-assisted cataract surgery using either group 1 high pulse energy: LenSx (Alcon Laboratories) (N = 100) or group 2 low pulse energy: FEMTO LDV Z8 (Ziemer) (N = 100) laser were reviewed retrospectively. Integrity of anterior capsulotomy, classified as (1) complete (free-floating or with minor microadhesions), (2) incomplete and (3) with capsular tears, intraoperative completeness of the clear corneal incisions (CCI, main incision and side port), incidences of intraoperative miosis and incidence of subconjunctival hemorrhage were evaluated and compared between the two groups. The proportion of complete capsulotomies was significantly higher in the group 2 than the group 1 (100% vs 94%; p = 0.03). The incidences of intraoperative miosis (0% vs 19%) and subconjunctival hemorrhage (1% vs 63%) were significantly lower in the group 2 than the group 1 (p < 0.001). Completeness of the main incision was comparable (97% vs 95%; p = 0.721) between the two groups. Although not statistically significant, the completeness of side-port incision was slightly better in the group 2 than the group 1 (91% vs 86%). Low energy laser system performed significantly better in terms of completeness of capsulotomy, intraoperative miosis and sub-conjunctival hemorrhage, compared with high energy laser; the CCI outcomes were comparable.
url https://doi.org/10.1038/s41598-021-89046-1
work_keys_str_mv AT hungyuanlin surgicaloutcomeswithhighandlowpulseenergyfemtosecondlasersystemsforcataractsurgery
AT yajungchuang surgicaloutcomeswithhighandlowpulseenergyfemtosecondlasersystemsforcataractsurgery
AT pijunglin surgicaloutcomeswithhighandlowpulseenergyfemtosecondlasersystemsforcataractsurgery
_version_ 1721454229060583424