Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation

OBJETIVO: A troca valvar aórtica é procedimento rotineiro, envolve substituição da valva nativa/prótese. Na maioria destes pacientes o risco é aceitável, porém, em alguns casos, o risco predito pode justificar contra-indicação. O implante de valva aórtica minimamente invasivo transcateter e sem circ...

Full description

Bibliographic Details
Main Authors: Diego Felipe Gaia, José Honório Palma, José Augusto Marcondes de Souza, José Cícero Stocco Guilhen, Andre Telis, Claudio Henrique Fischer, Carolina Baeta Neves Duarte Ferreira, Enio Buffolo
Format: Article
Language:English
Published: Sociedade Brasileira de Cirurgia Cardiovascular 2009-06-01
Series:Brazilian Journal of Cardiovascular Surgery
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382009000200021
id doaj-0b9f3a466e97469bb9528cc8bccdf322
record_format Article
collection DOAJ
language English
format Article
sources DOAJ
author Diego Felipe Gaia
José Honório Palma
José Augusto Marcondes de Souza
José Cícero Stocco Guilhen
Andre Telis
Claudio Henrique Fischer
Carolina Baeta Neves Duarte Ferreira
Enio Buffolo
spellingShingle Diego Felipe Gaia
José Honório Palma
José Augusto Marcondes de Souza
José Cícero Stocco Guilhen
Andre Telis
Claudio Henrique Fischer
Carolina Baeta Neves Duarte Ferreira
Enio Buffolo
Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation
Brazilian Journal of Cardiovascular Surgery
Valva aórtica
Ponte cardiopulmonar
Cateterismo cardíaco
Aortic valve
Cardiopulmonary bypass
Heart catheterization
author_facet Diego Felipe Gaia
José Honório Palma
José Augusto Marcondes de Souza
José Cícero Stocco Guilhen
Andre Telis
Claudio Henrique Fischer
Carolina Baeta Neves Duarte Ferreira
Enio Buffolo
author_sort Diego Felipe Gaia
title Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation
title_short Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation
title_full Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation
title_fullStr Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation
title_full_unstemmed Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation
title_sort implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea off-pump transapical balloon-expandable aortic valve endoprosthesis implantation
publisher Sociedade Brasileira de Cirurgia Cardiovascular
series Brazilian Journal of Cardiovascular Surgery
issn 0102-7638
1678-9741
publishDate 2009-06-01
description OBJETIVO: A troca valvar aórtica é procedimento rotineiro, envolve substituição da valva nativa/prótese. Na maioria destes pacientes o risco é aceitável, porém, em alguns casos, o risco predito pode justificar contra-indicação. O implante de valva aórtica minimamente invasivo transcateter e sem circulação extracorpórea (CEC) tem se mostrado viável, com menor morbi-mortalidade. O objetivo deste trabalho foi desenvolver bioprótese aórtica, montada em cateter, para implante sem CEC. MÉTODOS: Após desenvolvimento em animais, três pacientes com EuroSCORE elevado foram submetidos ao implante. Caso 1: portador de bioprótese com disfunção; Caso 2: estenose aórtica grave; Caso 3: disfunção de bioprótese aórtica. Após minitoracotomia e sob controle ecocardiográfico e fluoroscópico, cateter-balão foi posicionado sobre posição aórtica e insuflado. Após, segundo cateter-balão, com endoprótese valvada, foi posicionado e liberado sob alta frequência ventricular. Controles angiográficos e ecocardiográficos foram realizados e pacientes encaminhados para UTI. RESULTADOS: No primeiro caso foi possível implante sem CEC com resultados adequados. Evoluiu com melhora da função ventricular. Cursou com broncopneumonia, fístula traqueo-esofágica e óbito por mediastinite. Necropsia confirmou bom posicionamento valvar e preservação dos folhetos. O segundo caso apresentou migração do dispositivo após insuflação do balão, necessidade de esternotomia mediana de urgência, CEC e troca valvar convencional. O paciente evoluiu bem, recebendo alta da UTI 14 dias após procedimento e sem complicações. Cursou com infecção respiratória, choque séptico e óbito no 60º pós-operatório. O terceiro caso foi submetido a implante com sucesso. CONCLUSÃO: O implante de bioprótese transapical montada em cateter sem CEC mostrou ser procedimento factível. Detalhes técnicos e a curva de aprendizado demandam discussão.<br>OBJECTIVE: The aortic valve replacement is a routine procedure, and involves replacement of the native valve/prosthesis. In most of the patients who undergo such procedure the risk is acceptable, but in some cases, such risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation without cardiopulmonary bypass (CPB) has been shown to be viable, with lower morbidity and mortality. The aim of this study was to develop a catheter-mounted aortic bioprosthesis for implantation without CPB. METHODS: After developing in animals, three patients with high EuroSCORE underwent implantation. Case 1: patients with bioprosthesis dysfunction; Case 2: severe aortic stenosis; Case 3: dysfunction of aortic bioprosthesis. After minithoracotomy and under echocardiographic and fluoroscopic control, a balloon catheter was placed on aortic position and inflated. After, a second balloon with valved endoprosthesis was positioned and released under high ventricular rate. Echocardiographic and angiographic controls were performed and the patients were referred to ICU. RESULTS: In the first case, implantation without CPB was possible with appropriate results. The patient evolved with improvement of ventricular function. After, this patient developed bronchopneumonia, tracheoesophageal fistula and died due to mediastinitis. Autopsy confirmed proper valve positioning and leaflets preservation. The second case showed the device migration after inflation of the balloon, with the need for urgent median sternotomy, CPB and conventional valve replacement. This patient evolved well and was discharged from the ICU on the 14th postoperative day without complications. This patient developed respiratory infection, septic shock and died on the 60th postoperative day. The patient from the third case underwent successful implantation. CONCLUSION: The off-pump transapical implantation of catheter-mounted bioprosthesis was shown to be a feasible procedure. Technical details and learning curve require further discussion.
topic Valva aórtica
Ponte cardiopulmonar
Cateterismo cardíaco
Aortic valve
Cardiopulmonary bypass
Heart catheterization
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382009000200021
work_keys_str_mv AT diegofelipegaia implantetransapicaldeendoprotesevalvadabalaoexpansivelemposicaoaorticasemcirculacaoextracorporeaoffpumptransapicalballoonexpandableaorticvalveendoprosthesisimplantation
AT josehonoriopalma implantetransapicaldeendoprotesevalvadabalaoexpansivelemposicaoaorticasemcirculacaoextracorporeaoffpumptransapicalballoonexpandableaorticvalveendoprosthesisimplantation
AT joseaugustomarcondesdesouza implantetransapicaldeendoprotesevalvadabalaoexpansivelemposicaoaorticasemcirculacaoextracorporeaoffpumptransapicalballoonexpandableaorticvalveendoprosthesisimplantation
AT josecicerostoccoguilhen implantetransapicaldeendoprotesevalvadabalaoexpansivelemposicaoaorticasemcirculacaoextracorporeaoffpumptransapicalballoonexpandableaorticvalveendoprosthesisimplantation
AT andretelis implantetransapicaldeendoprotesevalvadabalaoexpansivelemposicaoaorticasemcirculacaoextracorporeaoffpumptransapicalballoonexpandableaorticvalveendoprosthesisimplantation
AT claudiohenriquefischer implantetransapicaldeendoprotesevalvadabalaoexpansivelemposicaoaorticasemcirculacaoextracorporeaoffpumptransapicalballoonexpandableaorticvalveendoprosthesisimplantation
AT carolinabaetanevesduarteferreira implantetransapicaldeendoprotesevalvadabalaoexpansivelemposicaoaorticasemcirculacaoextracorporeaoffpumptransapicalballoonexpandableaorticvalveendoprosthesisimplantation
AT eniobuffolo implantetransapicaldeendoprotesevalvadabalaoexpansivelemposicaoaorticasemcirculacaoextracorporeaoffpumptransapicalballoonexpandableaorticvalveendoprosthesisimplantation
_version_ 1725965773665468416
spelling doaj-0b9f3a466e97469bb9528cc8bccdf3222020-11-24T21:29:45ZengSociedade Brasileira de Cirurgia CardiovascularBrazilian Journal of Cardiovascular Surgery0102-76381678-97412009-06-0124223323810.1590/S0102-76382009000200021Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantationDiego Felipe GaiaJosé Honório PalmaJosé Augusto Marcondes de SouzaJosé Cícero Stocco GuilhenAndre TelisClaudio Henrique FischerCarolina Baeta Neves Duarte FerreiraEnio BuffoloOBJETIVO: A troca valvar aórtica é procedimento rotineiro, envolve substituição da valva nativa/prótese. Na maioria destes pacientes o risco é aceitável, porém, em alguns casos, o risco predito pode justificar contra-indicação. O implante de valva aórtica minimamente invasivo transcateter e sem circulação extracorpórea (CEC) tem se mostrado viável, com menor morbi-mortalidade. O objetivo deste trabalho foi desenvolver bioprótese aórtica, montada em cateter, para implante sem CEC. MÉTODOS: Após desenvolvimento em animais, três pacientes com EuroSCORE elevado foram submetidos ao implante. Caso 1: portador de bioprótese com disfunção; Caso 2: estenose aórtica grave; Caso 3: disfunção de bioprótese aórtica. Após minitoracotomia e sob controle ecocardiográfico e fluoroscópico, cateter-balão foi posicionado sobre posição aórtica e insuflado. Após, segundo cateter-balão, com endoprótese valvada, foi posicionado e liberado sob alta frequência ventricular. Controles angiográficos e ecocardiográficos foram realizados e pacientes encaminhados para UTI. RESULTADOS: No primeiro caso foi possível implante sem CEC com resultados adequados. Evoluiu com melhora da função ventricular. Cursou com broncopneumonia, fístula traqueo-esofágica e óbito por mediastinite. Necropsia confirmou bom posicionamento valvar e preservação dos folhetos. O segundo caso apresentou migração do dispositivo após insuflação do balão, necessidade de esternotomia mediana de urgência, CEC e troca valvar convencional. O paciente evoluiu bem, recebendo alta da UTI 14 dias após procedimento e sem complicações. Cursou com infecção respiratória, choque séptico e óbito no 60º pós-operatório. O terceiro caso foi submetido a implante com sucesso. CONCLUSÃO: O implante de bioprótese transapical montada em cateter sem CEC mostrou ser procedimento factível. Detalhes técnicos e a curva de aprendizado demandam discussão.<br>OBJECTIVE: The aortic valve replacement is a routine procedure, and involves replacement of the native valve/prosthesis. In most of the patients who undergo such procedure the risk is acceptable, but in some cases, such risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation without cardiopulmonary bypass (CPB) has been shown to be viable, with lower morbidity and mortality. The aim of this study was to develop a catheter-mounted aortic bioprosthesis for implantation without CPB. METHODS: After developing in animals, three patients with high EuroSCORE underwent implantation. Case 1: patients with bioprosthesis dysfunction; Case 2: severe aortic stenosis; Case 3: dysfunction of aortic bioprosthesis. After minithoracotomy and under echocardiographic and fluoroscopic control, a balloon catheter was placed on aortic position and inflated. After, a second balloon with valved endoprosthesis was positioned and released under high ventricular rate. Echocardiographic and angiographic controls were performed and the patients were referred to ICU. RESULTS: In the first case, implantation without CPB was possible with appropriate results. The patient evolved with improvement of ventricular function. After, this patient developed bronchopneumonia, tracheoesophageal fistula and died due to mediastinitis. Autopsy confirmed proper valve positioning and leaflets preservation. The second case showed the device migration after inflation of the balloon, with the need for urgent median sternotomy, CPB and conventional valve replacement. This patient evolved well and was discharged from the ICU on the 14th postoperative day without complications. This patient developed respiratory infection, septic shock and died on the 60th postoperative day. The patient from the third case underwent successful implantation. CONCLUSION: The off-pump transapical implantation of catheter-mounted bioprosthesis was shown to be a feasible procedure. Technical details and learning curve require further discussion.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382009000200021Valva aórticaPonte cardiopulmonarCateterismo cardíacoAortic valveCardiopulmonary bypassHeart catheterization