Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation
OBJETIVO: A troca valvar aórtica é procedimento rotineiro, envolve substituição da valva nativa/prótese. Na maioria destes pacientes o risco é aceitável, porém, em alguns casos, o risco predito pode justificar contra-indicação. O implante de valva aórtica minimamente invasivo transcateter e sem circ...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Sociedade Brasileira de Cirurgia Cardiovascular
2009-06-01
|
Series: | Brazilian Journal of Cardiovascular Surgery |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382009000200021 |
id |
doaj-0b9f3a466e97469bb9528cc8bccdf322 |
---|---|
record_format |
Article |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Diego Felipe Gaia José Honório Palma José Augusto Marcondes de Souza José Cícero Stocco Guilhen Andre Telis Claudio Henrique Fischer Carolina Baeta Neves Duarte Ferreira Enio Buffolo |
spellingShingle |
Diego Felipe Gaia José Honório Palma José Augusto Marcondes de Souza José Cícero Stocco Guilhen Andre Telis Claudio Henrique Fischer Carolina Baeta Neves Duarte Ferreira Enio Buffolo Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation Brazilian Journal of Cardiovascular Surgery Valva aórtica Ponte cardiopulmonar Cateterismo cardíaco Aortic valve Cardiopulmonary bypass Heart catheterization |
author_facet |
Diego Felipe Gaia José Honório Palma José Augusto Marcondes de Souza José Cícero Stocco Guilhen Andre Telis Claudio Henrique Fischer Carolina Baeta Neves Duarte Ferreira Enio Buffolo |
author_sort |
Diego Felipe Gaia |
title |
Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation |
title_short |
Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation |
title_full |
Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation |
title_fullStr |
Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation |
title_full_unstemmed |
Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation |
title_sort |
implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea off-pump transapical balloon-expandable aortic valve endoprosthesis implantation |
publisher |
Sociedade Brasileira de Cirurgia Cardiovascular |
series |
Brazilian Journal of Cardiovascular Surgery |
issn |
0102-7638 1678-9741 |
publishDate |
2009-06-01 |
description |
OBJETIVO: A troca valvar aórtica é procedimento rotineiro, envolve substituição da valva nativa/prótese. Na maioria destes pacientes o risco é aceitável, porém, em alguns casos, o risco predito pode justificar contra-indicação. O implante de valva aórtica minimamente invasivo transcateter e sem circulação extracorpórea (CEC) tem se mostrado viável, com menor morbi-mortalidade. O objetivo deste trabalho foi desenvolver bioprótese aórtica, montada em cateter, para implante sem CEC. MÉTODOS: Após desenvolvimento em animais, três pacientes com EuroSCORE elevado foram submetidos ao implante. Caso 1: portador de bioprótese com disfunção; Caso 2: estenose aórtica grave; Caso 3: disfunção de bioprótese aórtica. Após minitoracotomia e sob controle ecocardiográfico e fluoroscópico, cateter-balão foi posicionado sobre posição aórtica e insuflado. Após, segundo cateter-balão, com endoprótese valvada, foi posicionado e liberado sob alta frequência ventricular. Controles angiográficos e ecocardiográficos foram realizados e pacientes encaminhados para UTI. RESULTADOS: No primeiro caso foi possível implante sem CEC com resultados adequados. Evoluiu com melhora da função ventricular. Cursou com broncopneumonia, fístula traqueo-esofágica e óbito por mediastinite. Necropsia confirmou bom posicionamento valvar e preservação dos folhetos. O segundo caso apresentou migração do dispositivo após insuflação do balão, necessidade de esternotomia mediana de urgência, CEC e troca valvar convencional. O paciente evoluiu bem, recebendo alta da UTI 14 dias após procedimento e sem complicações. Cursou com infecção respiratória, choque séptico e óbito no 60º pós-operatório. O terceiro caso foi submetido a implante com sucesso. CONCLUSÃO: O implante de bioprótese transapical montada em cateter sem CEC mostrou ser procedimento factível. Detalhes técnicos e a curva de aprendizado demandam discussão.<br>OBJECTIVE: The aortic valve replacement is a routine procedure, and involves replacement of the native valve/prosthesis. In most of the patients who undergo such procedure the risk is acceptable, but in some cases, such risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation without cardiopulmonary bypass (CPB) has been shown to be viable, with lower morbidity and mortality. The aim of this study was to develop a catheter-mounted aortic bioprosthesis for implantation without CPB. METHODS: After developing in animals, three patients with high EuroSCORE underwent implantation. Case 1: patients with bioprosthesis dysfunction; Case 2: severe aortic stenosis; Case 3: dysfunction of aortic bioprosthesis. After minithoracotomy and under echocardiographic and fluoroscopic control, a balloon catheter was placed on aortic position and inflated. After, a second balloon with valved endoprosthesis was positioned and released under high ventricular rate. Echocardiographic and angiographic controls were performed and the patients were referred to ICU. RESULTS: In the first case, implantation without CPB was possible with appropriate results. The patient evolved with improvement of ventricular function. After, this patient developed bronchopneumonia, tracheoesophageal fistula and died due to mediastinitis. Autopsy confirmed proper valve positioning and leaflets preservation. The second case showed the device migration after inflation of the balloon, with the need for urgent median sternotomy, CPB and conventional valve replacement. This patient evolved well and was discharged from the ICU on the 14th postoperative day without complications. This patient developed respiratory infection, septic shock and died on the 60th postoperative day. The patient from the third case underwent successful implantation. CONCLUSION: The off-pump transapical implantation of catheter-mounted bioprosthesis was shown to be a feasible procedure. Technical details and learning curve require further discussion. |
topic |
Valva aórtica Ponte cardiopulmonar Cateterismo cardíaco Aortic valve Cardiopulmonary bypass Heart catheterization |
url |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382009000200021 |
work_keys_str_mv |
AT diegofelipegaia implantetransapicaldeendoprotesevalvadabalaoexpansivelemposicaoaorticasemcirculacaoextracorporeaoffpumptransapicalballoonexpandableaorticvalveendoprosthesisimplantation AT josehonoriopalma implantetransapicaldeendoprotesevalvadabalaoexpansivelemposicaoaorticasemcirculacaoextracorporeaoffpumptransapicalballoonexpandableaorticvalveendoprosthesisimplantation AT joseaugustomarcondesdesouza implantetransapicaldeendoprotesevalvadabalaoexpansivelemposicaoaorticasemcirculacaoextracorporeaoffpumptransapicalballoonexpandableaorticvalveendoprosthesisimplantation AT josecicerostoccoguilhen implantetransapicaldeendoprotesevalvadabalaoexpansivelemposicaoaorticasemcirculacaoextracorporeaoffpumptransapicalballoonexpandableaorticvalveendoprosthesisimplantation AT andretelis implantetransapicaldeendoprotesevalvadabalaoexpansivelemposicaoaorticasemcirculacaoextracorporeaoffpumptransapicalballoonexpandableaorticvalveendoprosthesisimplantation AT claudiohenriquefischer implantetransapicaldeendoprotesevalvadabalaoexpansivelemposicaoaorticasemcirculacaoextracorporeaoffpumptransapicalballoonexpandableaorticvalveendoprosthesisimplantation AT carolinabaetanevesduarteferreira implantetransapicaldeendoprotesevalvadabalaoexpansivelemposicaoaorticasemcirculacaoextracorporeaoffpumptransapicalballoonexpandableaorticvalveendoprosthesisimplantation AT eniobuffolo implantetransapicaldeendoprotesevalvadabalaoexpansivelemposicaoaorticasemcirculacaoextracorporeaoffpumptransapicalballoonexpandableaorticvalveendoprosthesisimplantation |
_version_ |
1725965773665468416 |
spelling |
doaj-0b9f3a466e97469bb9528cc8bccdf3222020-11-24T21:29:45ZengSociedade Brasileira de Cirurgia CardiovascularBrazilian Journal of Cardiovascular Surgery0102-76381678-97412009-06-0124223323810.1590/S0102-76382009000200021Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantationDiego Felipe GaiaJosé Honório PalmaJosé Augusto Marcondes de SouzaJosé Cícero Stocco GuilhenAndre TelisClaudio Henrique FischerCarolina Baeta Neves Duarte FerreiraEnio BuffoloOBJETIVO: A troca valvar aórtica é procedimento rotineiro, envolve substituição da valva nativa/prótese. Na maioria destes pacientes o risco é aceitável, porém, em alguns casos, o risco predito pode justificar contra-indicação. O implante de valva aórtica minimamente invasivo transcateter e sem circulação extracorpórea (CEC) tem se mostrado viável, com menor morbi-mortalidade. O objetivo deste trabalho foi desenvolver bioprótese aórtica, montada em cateter, para implante sem CEC. MÉTODOS: Após desenvolvimento em animais, três pacientes com EuroSCORE elevado foram submetidos ao implante. Caso 1: portador de bioprótese com disfunção; Caso 2: estenose aórtica grave; Caso 3: disfunção de bioprótese aórtica. Após minitoracotomia e sob controle ecocardiográfico e fluoroscópico, cateter-balão foi posicionado sobre posição aórtica e insuflado. Após, segundo cateter-balão, com endoprótese valvada, foi posicionado e liberado sob alta frequência ventricular. Controles angiográficos e ecocardiográficos foram realizados e pacientes encaminhados para UTI. RESULTADOS: No primeiro caso foi possível implante sem CEC com resultados adequados. Evoluiu com melhora da função ventricular. Cursou com broncopneumonia, fístula traqueo-esofágica e óbito por mediastinite. Necropsia confirmou bom posicionamento valvar e preservação dos folhetos. O segundo caso apresentou migração do dispositivo após insuflação do balão, necessidade de esternotomia mediana de urgência, CEC e troca valvar convencional. O paciente evoluiu bem, recebendo alta da UTI 14 dias após procedimento e sem complicações. Cursou com infecção respiratória, choque séptico e óbito no 60º pós-operatório. O terceiro caso foi submetido a implante com sucesso. CONCLUSÃO: O implante de bioprótese transapical montada em cateter sem CEC mostrou ser procedimento factível. Detalhes técnicos e a curva de aprendizado demandam discussão.<br>OBJECTIVE: The aortic valve replacement is a routine procedure, and involves replacement of the native valve/prosthesis. In most of the patients who undergo such procedure the risk is acceptable, but in some cases, such risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation without cardiopulmonary bypass (CPB) has been shown to be viable, with lower morbidity and mortality. The aim of this study was to develop a catheter-mounted aortic bioprosthesis for implantation without CPB. METHODS: After developing in animals, three patients with high EuroSCORE underwent implantation. Case 1: patients with bioprosthesis dysfunction; Case 2: severe aortic stenosis; Case 3: dysfunction of aortic bioprosthesis. After minithoracotomy and under echocardiographic and fluoroscopic control, a balloon catheter was placed on aortic position and inflated. After, a second balloon with valved endoprosthesis was positioned and released under high ventricular rate. Echocardiographic and angiographic controls were performed and the patients were referred to ICU. RESULTS: In the first case, implantation without CPB was possible with appropriate results. The patient evolved with improvement of ventricular function. After, this patient developed bronchopneumonia, tracheoesophageal fistula and died due to mediastinitis. Autopsy confirmed proper valve positioning and leaflets preservation. The second case showed the device migration after inflation of the balloon, with the need for urgent median sternotomy, CPB and conventional valve replacement. This patient evolved well and was discharged from the ICU on the 14th postoperative day without complications. This patient developed respiratory infection, septic shock and died on the 60th postoperative day. The patient from the third case underwent successful implantation. CONCLUSION: The off-pump transapical implantation of catheter-mounted bioprosthesis was shown to be a feasible procedure. Technical details and learning curve require further discussion.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382009000200021Valva aórticaPonte cardiopulmonarCateterismo cardíacoAortic valveCardiopulmonary bypassHeart catheterization |