Novel Barrier Enclosure for Both Aerosol and Droplet Protection Model

Emergency physicians are on the front lines of treating patients with highly infectious respiratory diseases. Personal protective equipment is one defense against contamination from droplet and aerosol secretions. Intubation is a procedure that greatly can increase provider’s risk of exposure. Utili...

Full description

Bibliographic Details
Main Authors: Chad E. Branecki, Nicholas J. Jobeun, Tyler J. Ronnfeldt, Michael A. Ash, Thomas E. Schulte, Jason G. Langenfeld
Format: Article
Language:English
Published: eScholarship Publishing, University of California 2020-07-01
Series:Western Journal of Emergency Medicine
Online Access:https://escholarship.org/uc/item/8db208ph
id doaj-0c27438a94e54afd9391847ab180bf50
record_format Article
spelling doaj-0c27438a94e54afd9391847ab180bf502020-11-25T02:45:03ZengeScholarship Publishing, University of CaliforniaWestern Journal of Emergency Medicine1936-90182020-07-0121410.5811/westjem.2020.6.47834wjem-21-790Novel Barrier Enclosure for Both Aerosol and Droplet Protection ModelChad E. Branecki0Nicholas J. Jobeun1Tyler J. Ronnfeldt2Michael A. Ash3Thomas E. Schulte4Jason G. Langenfeld5University of Nebraska College of Medicine, Department of Emergency Medicine, Omaha, NebraskaUniversity of Nebraska College of Medicine, Department of Emergency Medicine, Omaha, NebraskaUniversity of Nebraska College of Medicine, Department of Emergency Medicine, Omaha, NebraskaUniversity of Nebraska College of Medicine, Department of Internal Medicine, Omaha, NebraskaUniversity of Nebraska College of Medicine, Department of Anesthesia, Omaha, NebraskaUniversity of Nebraska College of Medicine, Department of Emergency Medicine, Omaha, NebraskaEmergency physicians are on the front lines of treating patients with highly infectious respiratory diseases. Personal protective equipment is one defense against contamination from droplet and aerosol secretions. Intubation is a procedure that greatly can increase provider’s risk of exposure. Utilization of an intubation box has been discussed and recommended on social media platforms. There has been scant literature demonstrating the effectiveness of such devices. This study aimed to determine degree of droplet contamination to the intubator utilizing a novel barrier enclosure with a fluorescent simulated respiratory contagion. This model confirmed both added protection to the providers preforming intubation, and reduction of spread of the droplets when such a device is applied to patient care.https://escholarship.org/uc/item/8db208ph
collection DOAJ
language English
format Article
sources DOAJ
author Chad E. Branecki
Nicholas J. Jobeun
Tyler J. Ronnfeldt
Michael A. Ash
Thomas E. Schulte
Jason G. Langenfeld
spellingShingle Chad E. Branecki
Nicholas J. Jobeun
Tyler J. Ronnfeldt
Michael A. Ash
Thomas E. Schulte
Jason G. Langenfeld
Novel Barrier Enclosure for Both Aerosol and Droplet Protection Model
Western Journal of Emergency Medicine
author_facet Chad E. Branecki
Nicholas J. Jobeun
Tyler J. Ronnfeldt
Michael A. Ash
Thomas E. Schulte
Jason G. Langenfeld
author_sort Chad E. Branecki
title Novel Barrier Enclosure for Both Aerosol and Droplet Protection Model
title_short Novel Barrier Enclosure for Both Aerosol and Droplet Protection Model
title_full Novel Barrier Enclosure for Both Aerosol and Droplet Protection Model
title_fullStr Novel Barrier Enclosure for Both Aerosol and Droplet Protection Model
title_full_unstemmed Novel Barrier Enclosure for Both Aerosol and Droplet Protection Model
title_sort novel barrier enclosure for both aerosol and droplet protection model
publisher eScholarship Publishing, University of California
series Western Journal of Emergency Medicine
issn 1936-9018
publishDate 2020-07-01
description Emergency physicians are on the front lines of treating patients with highly infectious respiratory diseases. Personal protective equipment is one defense against contamination from droplet and aerosol secretions. Intubation is a procedure that greatly can increase provider’s risk of exposure. Utilization of an intubation box has been discussed and recommended on social media platforms. There has been scant literature demonstrating the effectiveness of such devices. This study aimed to determine degree of droplet contamination to the intubator utilizing a novel barrier enclosure with a fluorescent simulated respiratory contagion. This model confirmed both added protection to the providers preforming intubation, and reduction of spread of the droplets when such a device is applied to patient care.
url https://escholarship.org/uc/item/8db208ph
work_keys_str_mv AT chadebranecki novelbarrierenclosureforbothaerosolanddropletprotectionmodel
AT nicholasjjobeun novelbarrierenclosureforbothaerosolanddropletprotectionmodel
AT tylerjronnfeldt novelbarrierenclosureforbothaerosolanddropletprotectionmodel
AT michaelaash novelbarrierenclosureforbothaerosolanddropletprotectionmodel
AT thomaseschulte novelbarrierenclosureforbothaerosolanddropletprotectionmodel
AT jasonglangenfeld novelbarrierenclosureforbothaerosolanddropletprotectionmodel
_version_ 1724764439584964608