Aortic Valve Replacement with a Conventional Stented Bioprosthesis versus Sutureless Bioprosthesis: a Study of 763 Patients

Abstract Objective: The aim of this retrospective study was to compare early postoperative outcomes after aortic valve replacement (AVR) with sutureless bioprostheses and conventional stented bioprostheses implanted through median sternotomy. Methods: From January 2011 to December 2016, 763 patien...

Full description

Bibliographic Details
Main Authors: Syed Saleem Mujtaba, Simon M. Ledingham, Asif Raza Shah, Thasee Pillay, Stephan Schueler, Stephen Clark
Format: Article
Language:English
Published: Sociedade Brasileira de Cirurgia Cardiovascular
Series:Brazilian Journal of Cardiovascular Surgery
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382018000200122&lng=en&tlng=en
id doaj-0f2a212ec01348b0943fe3dfea82a07c
record_format Article
spelling doaj-0f2a212ec01348b0943fe3dfea82a07c2020-11-24T22:08:20ZengSociedade Brasileira de Cirurgia CardiovascularBrazilian Journal of Cardiovascular Surgery1678-974133212212810.21470/1678-9741-2017-0088S0102-76382018000200122Aortic Valve Replacement with a Conventional Stented Bioprosthesis versus Sutureless Bioprosthesis: a Study of 763 PatientsSyed Saleem MujtabaSimon M. LedinghamAsif Raza ShahThasee PillayStephan SchuelerStephen ClarkAbstract Objective: The aim of this retrospective study was to compare early postoperative outcomes after aortic valve replacement (AVR) with sutureless bioprostheses and conventional stented bioprostheses implanted through median sternotomy. Methods: From January 2011 to December 2016, 763 patients underwent aortic valve replacement with bioprostheses; of these, 139 received a Perceval S sutureless valve (Group A) and 624 received a Perimount Magna Ease valve (Group B). These groups were further divided into A1 (isolated Perceval AVR), A2 (Perceval AVR with coronary artery bypass grafting [CABG]), B1 (isolated conventional stented bioprosthesis), and B2 (conventional stented bioprosthesis + CABG). Results: Patients in Group A were older (mean 74 years vs. 71 years; P<0.0001), predominantly women (53% vs. 32%; P<0.0001), had a higher logistic EuroSCORE (3.26 vs. 2.43; P<0.001), more preoperative atrial fibrillation (20% vs. 13%; P=0.03), and had a lower reopening rate for bleeding (2.1% vs. 6.7%; P=0.04). Compared to Group B1, Group A1 had shorter cross-clamp (mean 40 min vs. 57 min; P≤0.0001) and bypass times (mean 63 min vs. mean 80 min; P=0.02), and they bled less postoperatively (mean 295 ml vs. mean 393 ml; P=0.002). The mean gradient across Perceval valve was 12.5 mmHg while its effective orifice area was 1.5 cm2. Conclusion: In our retrospective study of 763 patients, sutureless valve group patients are older, mostly women, more symptomatic preoperatively, and have higher logistic EuroSCORE. They have shorter cross-clamp and bypass times, less postoperative bleeding, and reduced incidence of reopening. Further studies are needed to evaluate the clinical benefits in short, mid, and long-terms.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382018000200122&lng=en&tlng=enAortic Valve/SurgeryHeart Valve Prosthesis/UtilizationHeart Valve Prosthesis Implantation
collection DOAJ
language English
format Article
sources DOAJ
author Syed Saleem Mujtaba
Simon M. Ledingham
Asif Raza Shah
Thasee Pillay
Stephan Schueler
Stephen Clark
spellingShingle Syed Saleem Mujtaba
Simon M. Ledingham
Asif Raza Shah
Thasee Pillay
Stephan Schueler
Stephen Clark
Aortic Valve Replacement with a Conventional Stented Bioprosthesis versus Sutureless Bioprosthesis: a Study of 763 Patients
Brazilian Journal of Cardiovascular Surgery
Aortic Valve/Surgery
Heart Valve Prosthesis/Utilization
Heart Valve Prosthesis Implantation
author_facet Syed Saleem Mujtaba
Simon M. Ledingham
Asif Raza Shah
Thasee Pillay
Stephan Schueler
Stephen Clark
author_sort Syed Saleem Mujtaba
title Aortic Valve Replacement with a Conventional Stented Bioprosthesis versus Sutureless Bioprosthesis: a Study of 763 Patients
title_short Aortic Valve Replacement with a Conventional Stented Bioprosthesis versus Sutureless Bioprosthesis: a Study of 763 Patients
title_full Aortic Valve Replacement with a Conventional Stented Bioprosthesis versus Sutureless Bioprosthesis: a Study of 763 Patients
title_fullStr Aortic Valve Replacement with a Conventional Stented Bioprosthesis versus Sutureless Bioprosthesis: a Study of 763 Patients
title_full_unstemmed Aortic Valve Replacement with a Conventional Stented Bioprosthesis versus Sutureless Bioprosthesis: a Study of 763 Patients
title_sort aortic valve replacement with a conventional stented bioprosthesis versus sutureless bioprosthesis: a study of 763 patients
publisher Sociedade Brasileira de Cirurgia Cardiovascular
series Brazilian Journal of Cardiovascular Surgery
issn 1678-9741
description Abstract Objective: The aim of this retrospective study was to compare early postoperative outcomes after aortic valve replacement (AVR) with sutureless bioprostheses and conventional stented bioprostheses implanted through median sternotomy. Methods: From January 2011 to December 2016, 763 patients underwent aortic valve replacement with bioprostheses; of these, 139 received a Perceval S sutureless valve (Group A) and 624 received a Perimount Magna Ease valve (Group B). These groups were further divided into A1 (isolated Perceval AVR), A2 (Perceval AVR with coronary artery bypass grafting [CABG]), B1 (isolated conventional stented bioprosthesis), and B2 (conventional stented bioprosthesis + CABG). Results: Patients in Group A were older (mean 74 years vs. 71 years; P<0.0001), predominantly women (53% vs. 32%; P<0.0001), had a higher logistic EuroSCORE (3.26 vs. 2.43; P<0.001), more preoperative atrial fibrillation (20% vs. 13%; P=0.03), and had a lower reopening rate for bleeding (2.1% vs. 6.7%; P=0.04). Compared to Group B1, Group A1 had shorter cross-clamp (mean 40 min vs. 57 min; P≤0.0001) and bypass times (mean 63 min vs. mean 80 min; P=0.02), and they bled less postoperatively (mean 295 ml vs. mean 393 ml; P=0.002). The mean gradient across Perceval valve was 12.5 mmHg while its effective orifice area was 1.5 cm2. Conclusion: In our retrospective study of 763 patients, sutureless valve group patients are older, mostly women, more symptomatic preoperatively, and have higher logistic EuroSCORE. They have shorter cross-clamp and bypass times, less postoperative bleeding, and reduced incidence of reopening. Further studies are needed to evaluate the clinical benefits in short, mid, and long-terms.
topic Aortic Valve/Surgery
Heart Valve Prosthesis/Utilization
Heart Valve Prosthesis Implantation
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382018000200122&lng=en&tlng=en
work_keys_str_mv AT syedsaleemmujtaba aorticvalvereplacementwithaconventionalstentedbioprosthesisversussuturelessbioprosthesisastudyof763patients
AT simonmledingham aorticvalvereplacementwithaconventionalstentedbioprosthesisversussuturelessbioprosthesisastudyof763patients
AT asifrazashah aorticvalvereplacementwithaconventionalstentedbioprosthesisversussuturelessbioprosthesisastudyof763patients
AT thaseepillay aorticvalvereplacementwithaconventionalstentedbioprosthesisversussuturelessbioprosthesisastudyof763patients
AT stephanschueler aorticvalvereplacementwithaconventionalstentedbioprosthesisversussuturelessbioprosthesisastudyof763patients
AT stephenclark aorticvalvereplacementwithaconventionalstentedbioprosthesisversussuturelessbioprosthesisastudyof763patients
_version_ 1725816541800300544