Calculation of additional heat loss through heat-conducting inclusions (on the example of window reveal)

To solve the problem of improving the energy efficiency in buildings the materials with low thermal conductivity are used. The constructive difficulty of the modern walling and the heterogeneity of materials must be carefully calculated in designing, constructing and operating of buildings.The metho...

Full description

Bibliographic Details
Main Authors: I.S. Safin, D.V. Kraynov, A.S. Lyubimcev
Format: Article
Language:English
Published: Peter the Great St. Petersburg Polytechnic University 2010-10-01
Series:Инженерно-строительный журнал
Subjects:
Online Access:http://engstroy.spb.ru/index_2010_06/krainov_teplopoteri.pdf
id doaj-0f7049aefde14e60901ccbe80e8f6c8d
record_format Article
spelling doaj-0f7049aefde14e60901ccbe80e8f6c8d2020-11-25T01:41:14ZengPeter the Great St. Petersburg Polytechnic UniversityИнженерно-строительный журнал2071-47262071-03052010-10-011661722Calculation of additional heat loss through heat-conducting inclusions (on the example of window reveal)I.S. SafinD.V. KraynovA.S. LyubimcevTo solve the problem of improving the energy efficiency in buildings the materials with low thermal conductivity are used. The constructive difficulty of the modern walling and the heterogeneity of materials must be carefully calculated in designing, constructing and operating of buildings.The method of thermotechnical calculation based on the determination of the additional heat loss through heat-conducting inclusions (on the example of the jamb construction unit) has been considered in this work. The determination of the value of additional heat flows is carried out by calculating the temperature fields.The results show that the value of the additional heat flows depends not only on the constructive solution of nodes, but also on the architectural design of buildings. That’s why it is necessary to define a reduced thermal resistance for each building’s facade. The proportion of heat loss through consideration of heat-conducting inclusion of major heat loss, calculated by design coats, can reach more than 20%.http://engstroy.spb.ru/index_2010_06/krainov_teplopoteri.pdfenergy efficiencyheat-conducting inclusionsreduced thermal resistancetemperature fields
collection DOAJ
language English
format Article
sources DOAJ
author I.S. Safin
D.V. Kraynov
A.S. Lyubimcev
spellingShingle I.S. Safin
D.V. Kraynov
A.S. Lyubimcev
Calculation of additional heat loss through heat-conducting inclusions (on the example of window reveal)
Инженерно-строительный журнал
energy efficiency
heat-conducting inclusions
reduced thermal resistance
temperature fields
author_facet I.S. Safin
D.V. Kraynov
A.S. Lyubimcev
author_sort I.S. Safin
title Calculation of additional heat loss through heat-conducting inclusions (on the example of window reveal)
title_short Calculation of additional heat loss through heat-conducting inclusions (on the example of window reveal)
title_full Calculation of additional heat loss through heat-conducting inclusions (on the example of window reveal)
title_fullStr Calculation of additional heat loss through heat-conducting inclusions (on the example of window reveal)
title_full_unstemmed Calculation of additional heat loss through heat-conducting inclusions (on the example of window reveal)
title_sort calculation of additional heat loss through heat-conducting inclusions (on the example of window reveal)
publisher Peter the Great St. Petersburg Polytechnic University
series Инженерно-строительный журнал
issn 2071-4726
2071-0305
publishDate 2010-10-01
description To solve the problem of improving the energy efficiency in buildings the materials with low thermal conductivity are used. The constructive difficulty of the modern walling and the heterogeneity of materials must be carefully calculated in designing, constructing and operating of buildings.The method of thermotechnical calculation based on the determination of the additional heat loss through heat-conducting inclusions (on the example of the jamb construction unit) has been considered in this work. The determination of the value of additional heat flows is carried out by calculating the temperature fields.The results show that the value of the additional heat flows depends not only on the constructive solution of nodes, but also on the architectural design of buildings. That’s why it is necessary to define a reduced thermal resistance for each building’s facade. The proportion of heat loss through consideration of heat-conducting inclusion of major heat loss, calculated by design coats, can reach more than 20%.
topic energy efficiency
heat-conducting inclusions
reduced thermal resistance
temperature fields
url http://engstroy.spb.ru/index_2010_06/krainov_teplopoteri.pdf
work_keys_str_mv AT issafin calculationofadditionalheatlossthroughheatconductinginclusionsontheexampleofwindowreveal
AT dvkraynov calculationofadditionalheatlossthroughheatconductinginclusionsontheexampleofwindowreveal
AT aslyubimcev calculationofadditionalheatlossthroughheatconductinginclusionsontheexampleofwindowreveal
_version_ 1725041952759480320