Research on Discrete Fourier Transform-Based Phasor Measurement Algorithm for Distribution Network under High Frequency Sampling

This paper proposes a phasor measurement algorithm that is suitable for a distribution network. Under the condition of fixed interval and high frequency sampling, the algorithm uses a dynamic calibration factor to correct the traditional Discrete Fourier Transform (DFT) algorithm, which solves the s...

Full description

Bibliographic Details
Main Authors: Zhiguo Zhou, Ruliang Lin, Lifeng Wang, Yi Wang, Hansen Li
Format: Article
Language:English
Published: MDPI AG 2018-08-01
Series:Energies
Subjects:
DFT
Online Access:http://www.mdpi.com/1996-1073/11/9/2203
id doaj-126ba05f750b48f4a24ebac57f2cb09b
record_format Article
spelling doaj-126ba05f750b48f4a24ebac57f2cb09b2020-11-24T23:53:18ZengMDPI AGEnergies1996-10732018-08-01119220310.3390/en11092203en11092203Research on Discrete Fourier Transform-Based Phasor Measurement Algorithm for Distribution Network under High Frequency SamplingZhiguo Zhou0Ruliang Lin1Lifeng Wang2Yi Wang3Hansen Li4School of Information and Electronics, Beijing Institute of Technology, Beijing 100081, ChinaSchool of Information and Electronics, Beijing Institute of Technology, Beijing 100081, ChinaState Grid Jiangsu Electric Power Co., Ltd., Nanjing 210008, ChinaSchool of Information and Electronics, Beijing Institute of Technology, Beijing 100081, ChinaSchool of Information and Electronics, Beijing Institute of Technology, Beijing 100081, ChinaThis paper proposes a phasor measurement algorithm that is suitable for a distribution network. Under the condition of fixed interval and high frequency sampling, the algorithm uses a dynamic calibration factor to correct the traditional Discrete Fourier Transform (DFT) algorithm, which solves the shortcomings of the rapid decline in traditional algorithm measurement accuracy under the condition of power system frequency deviation or dynamic measurement. Under the high sampling rate of the international distribution network waveform data, the conventional phasor is used to represent the theoretical phasor, and the value of the conventional phasor is compensated to make the result closer to the theoretical value. Finally, the phasor measurement software simulation platform is built in Matlab/Simulink, based on the principle of the algorithm, providing a simulation environment for researchers to verify the phasor measurement algorithm of the distribution network and the fault location, state estimation, or other advanced applications.http://www.mdpi.com/1996-1073/11/9/2203distribution networkDFTphasor measurement algorithmdynamic testingmodeling
collection DOAJ
language English
format Article
sources DOAJ
author Zhiguo Zhou
Ruliang Lin
Lifeng Wang
Yi Wang
Hansen Li
spellingShingle Zhiguo Zhou
Ruliang Lin
Lifeng Wang
Yi Wang
Hansen Li
Research on Discrete Fourier Transform-Based Phasor Measurement Algorithm for Distribution Network under High Frequency Sampling
Energies
distribution network
DFT
phasor measurement algorithm
dynamic testing
modeling
author_facet Zhiguo Zhou
Ruliang Lin
Lifeng Wang
Yi Wang
Hansen Li
author_sort Zhiguo Zhou
title Research on Discrete Fourier Transform-Based Phasor Measurement Algorithm for Distribution Network under High Frequency Sampling
title_short Research on Discrete Fourier Transform-Based Phasor Measurement Algorithm for Distribution Network under High Frequency Sampling
title_full Research on Discrete Fourier Transform-Based Phasor Measurement Algorithm for Distribution Network under High Frequency Sampling
title_fullStr Research on Discrete Fourier Transform-Based Phasor Measurement Algorithm for Distribution Network under High Frequency Sampling
title_full_unstemmed Research on Discrete Fourier Transform-Based Phasor Measurement Algorithm for Distribution Network under High Frequency Sampling
title_sort research on discrete fourier transform-based phasor measurement algorithm for distribution network under high frequency sampling
publisher MDPI AG
series Energies
issn 1996-1073
publishDate 2018-08-01
description This paper proposes a phasor measurement algorithm that is suitable for a distribution network. Under the condition of fixed interval and high frequency sampling, the algorithm uses a dynamic calibration factor to correct the traditional Discrete Fourier Transform (DFT) algorithm, which solves the shortcomings of the rapid decline in traditional algorithm measurement accuracy under the condition of power system frequency deviation or dynamic measurement. Under the high sampling rate of the international distribution network waveform data, the conventional phasor is used to represent the theoretical phasor, and the value of the conventional phasor is compensated to make the result closer to the theoretical value. Finally, the phasor measurement software simulation platform is built in Matlab/Simulink, based on the principle of the algorithm, providing a simulation environment for researchers to verify the phasor measurement algorithm of the distribution network and the fault location, state estimation, or other advanced applications.
topic distribution network
DFT
phasor measurement algorithm
dynamic testing
modeling
url http://www.mdpi.com/1996-1073/11/9/2203
work_keys_str_mv AT zhiguozhou researchondiscretefouriertransformbasedphasormeasurementalgorithmfordistributionnetworkunderhighfrequencysampling
AT rulianglin researchondiscretefouriertransformbasedphasormeasurementalgorithmfordistributionnetworkunderhighfrequencysampling
AT lifengwang researchondiscretefouriertransformbasedphasormeasurementalgorithmfordistributionnetworkunderhighfrequencysampling
AT yiwang researchondiscretefouriertransformbasedphasormeasurementalgorithmfordistributionnetworkunderhighfrequencysampling
AT hansenli researchondiscretefouriertransformbasedphasormeasurementalgorithmfordistributionnetworkunderhighfrequencysampling
_version_ 1725470446867972096