Simple device to determine the pressure applied by pressure clips for the treatment of earlobe keloids

Background: Keloids of the ear are common problems. Various treatment modalities are available for the treatment of ear keloids. Surgical excision with intralesional steroid injection along with compression therapy has the least recurrence rate. Various types of devices are available for pressure th...

Full description

Bibliographic Details
Main Authors: Aashish Sasidharan, Ann David, Amish Gohil, Ashish Kumar Gupta
Format: Article
Language:English
Published: Thieme Medical Publishers, Inc. 2015-09-01
Series:Indian Journal of Plastic Surgery
Subjects:
Online Access:http://www.thieme-connect.de/DOI/DOI?10.4103/0970-0358.173128
id doaj-15eaeb6140ad453b8c14d399166a0cff
record_format Article
spelling doaj-15eaeb6140ad453b8c14d399166a0cff2020-11-25T03:52:53ZengThieme Medical Publishers, Inc.Indian Journal of Plastic Surgery0970-03581998-376X2015-09-01480329329610.4103/0970-0358.173128Simple device to determine the pressure applied by pressure clips for the treatment of earlobe keloidsAashish Sasidharan0Ann David1Amish Gohil2Ashish Kumar Gupta3Departments of Plastic and Reconstructive Surgery, Vellore, Tamil Nadu, IndiaBioengineering, Christian Medical College and Hospital, Vellore, Tamil Nadu, IndiaDepartments of Plastic and Reconstructive Surgery, Vellore, Tamil Nadu, IndiaDepartments of Plastic and Reconstructive Surgery, Vellore, Tamil Nadu, IndiaBackground: Keloids of the ear are common problems. Various treatment modalities are available for the treatment of ear keloids. Surgical excision with intralesional steroid injection along with compression therapy has the least recurrence rate. Various types of devices are available for pressure therapy. Pressure applied by these devices is uncontrolled and is associated with the risk of pressure necrosis. We describe here a simple and easy to use device to measure pressure applied by these clips for better outcome. Objectives: To devise a simple method to measure the pressure applied by various pressure clips used in ear keloid pressure therapy. Materials and Methods: By using a force sensitive resistor (FSR), the pressure applied gets converted into voltage using electrical wires, resistors, capacitors, converter, amplifier, diode, nine-volt (9V) cadmium battery and the voltage is measured using a multimeter. The measured voltage is then converted into pressure using pressure voltage graph that depicts the actual pressure applied by the pressure clip. Results: The pressure applied by different clips was variable. The spring clips were adjustable by slight variation in the design whereas the pressure applied by binder clips and magnet discs was not adjustable. Conclusion: The uncontrolled/suboptimal pressure applied by certain pressure clips can be monitored to provide optimal pressure therapy in ear keloid for better outcome.http://www.thieme-connect.de/DOI/DOI?10.4103/0970-0358.173128clipsdeviceearlobemagnetic discsmeasurepressure therapysplint
collection DOAJ
language English
format Article
sources DOAJ
author Aashish Sasidharan
Ann David
Amish Gohil
Ashish Kumar Gupta
spellingShingle Aashish Sasidharan
Ann David
Amish Gohil
Ashish Kumar Gupta
Simple device to determine the pressure applied by pressure clips for the treatment of earlobe keloids
Indian Journal of Plastic Surgery
clips
device
earlobe
magnetic discs
measure
pressure therapy
splint
author_facet Aashish Sasidharan
Ann David
Amish Gohil
Ashish Kumar Gupta
author_sort Aashish Sasidharan
title Simple device to determine the pressure applied by pressure clips for the treatment of earlobe keloids
title_short Simple device to determine the pressure applied by pressure clips for the treatment of earlobe keloids
title_full Simple device to determine the pressure applied by pressure clips for the treatment of earlobe keloids
title_fullStr Simple device to determine the pressure applied by pressure clips for the treatment of earlobe keloids
title_full_unstemmed Simple device to determine the pressure applied by pressure clips for the treatment of earlobe keloids
title_sort simple device to determine the pressure applied by pressure clips for the treatment of earlobe keloids
publisher Thieme Medical Publishers, Inc.
series Indian Journal of Plastic Surgery
issn 0970-0358
1998-376X
publishDate 2015-09-01
description Background: Keloids of the ear are common problems. Various treatment modalities are available for the treatment of ear keloids. Surgical excision with intralesional steroid injection along with compression therapy has the least recurrence rate. Various types of devices are available for pressure therapy. Pressure applied by these devices is uncontrolled and is associated with the risk of pressure necrosis. We describe here a simple and easy to use device to measure pressure applied by these clips for better outcome. Objectives: To devise a simple method to measure the pressure applied by various pressure clips used in ear keloid pressure therapy. Materials and Methods: By using a force sensitive resistor (FSR), the pressure applied gets converted into voltage using electrical wires, resistors, capacitors, converter, amplifier, diode, nine-volt (9V) cadmium battery and the voltage is measured using a multimeter. The measured voltage is then converted into pressure using pressure voltage graph that depicts the actual pressure applied by the pressure clip. Results: The pressure applied by different clips was variable. The spring clips were adjustable by slight variation in the design whereas the pressure applied by binder clips and magnet discs was not adjustable. Conclusion: The uncontrolled/suboptimal pressure applied by certain pressure clips can be monitored to provide optimal pressure therapy in ear keloid for better outcome.
topic clips
device
earlobe
magnetic discs
measure
pressure therapy
splint
url http://www.thieme-connect.de/DOI/DOI?10.4103/0970-0358.173128
work_keys_str_mv AT aashishsasidharan simpledevicetodeterminethepressureappliedbypressureclipsforthetreatmentofearlobekeloids
AT anndavid simpledevicetodeterminethepressureappliedbypressureclipsforthetreatmentofearlobekeloids
AT amishgohil simpledevicetodeterminethepressureappliedbypressureclipsforthetreatmentofearlobekeloids
AT ashishkumargupta simpledevicetodeterminethepressureappliedbypressureclipsforthetreatmentofearlobekeloids
_version_ 1724480384197984256