Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
In this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensor...
Main Author: | Małgorzata Jędrzejewska-Szczerska |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2014-04-01
|
Series: | Sensors |
Subjects: | |
Online Access: | http://www.mdpi.com/1424-8220/14/4/6965 |
Similar Items
-
The Effects and Applications of Erbium Doped Fiber Fabry-Perot Interferometers
by: Taylor, Justin K.
Published: (2010) -
Compact Powell-Lens-Based Low-Coherence Correlation Interrogation System for Fiber-Optic Fabry-Perot Sensors
by: Zhibo Ma, et al.
Published: (2019-01-01) -
Long-Sensing-Length Strain Sensor Based on Optical Fiber Fabry-Perot Interferometer With HCF-SMF Structure
by: Zhichao Lv, et al.
Published: (2019-01-01) -
Fabry-Perot Interferometer Performance as Temperature Sensor for Use in Electrical Power System Applications
by: Sanjoy Mandal
Published: (2007-09-01) -
Intrinsic Fabry-Perot Interferometeric Sensor Based on Microfiber Created by Chemical Etching
by: Ruohui Wang, et al.
Published: (2014-09-01)