Flow Injection Analysis of Mercury Using 4-(Dimethylamino) Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire Electrode

A flow injection analysis (FIA) incorporating a thiosemicarbazone-based coated wire electrode (CWE) was developed method for the determination of mercury(II). A 0.1 M KNO3 carrier stream with pH between 1 and 5 and flow rate of 1 mL·min−1 were used as optimum parameters. A...

Full description

Bibliographic Details
Main Authors: Sulaiman Ab Ghani, Abdussalam Salhin, Tara F. Tahir
Format: Article
Language:English
Published: MDPI AG 2012-11-01
Series:Sensors
Subjects:
Online Access:http://www.mdpi.com/1424-8220/12/11/14968
id doaj-1807747f5923447b8f64a26ff6bb3114
record_format Article
spelling doaj-1807747f5923447b8f64a26ff6bb31142020-11-24T22:24:27ZengMDPI AGSensors1424-82202012-11-011211149681498210.3390/s121114968Flow Injection Analysis of Mercury Using 4-(Dimethylamino) Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire ElectrodeSulaiman Ab GhaniAbdussalam SalhinTara F. TahirA flow injection analysis (FIA) incorporating a thiosemicarbazone-based coated wire electrode (CWE) was developed method for the determination of mercury(II). A 0.1 M KNO3 carrier stream with pH between 1 and 5 and flow rate of 1 mL·min−1 were used as optimum parameters. A linear plot within the concentration range of 5 × 10−6–0.1 M Hg(II), slope of 27.8 ± 1 mV per decade and correlation coefficient (R2) of 0.984 were obtained. The system was successfully applied for the determination of mercury(II) in dental amalgam solutions and spiked environmental water samples. Highly reproducible measurements with relative standard deviation (RSD < 1% (n = 3)) were obtained, giving a typical throughput of 30 samples·h−1.http://www.mdpi.com/1424-8220/12/11/14968coated wire electrode4-(dimethylamino) benzaldehyde-4-ethylthiosemicarbazonemercury(II) ion-selective electrodeflow injection analysis
collection DOAJ
language English
format Article
sources DOAJ
author Sulaiman Ab Ghani
Abdussalam Salhin
Tara F. Tahir
spellingShingle Sulaiman Ab Ghani
Abdussalam Salhin
Tara F. Tahir
Flow Injection Analysis of Mercury Using 4-(Dimethylamino) Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire Electrode
Sensors
coated wire electrode
4-(dimethylamino) benzaldehyde-4-ethylthiosemicarbazone
mercury(II) ion-selective electrode
flow injection analysis
author_facet Sulaiman Ab Ghani
Abdussalam Salhin
Tara F. Tahir
author_sort Sulaiman Ab Ghani
title Flow Injection Analysis of Mercury Using 4-(Dimethylamino) Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire Electrode
title_short Flow Injection Analysis of Mercury Using 4-(Dimethylamino) Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire Electrode
title_full Flow Injection Analysis of Mercury Using 4-(Dimethylamino) Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire Electrode
title_fullStr Flow Injection Analysis of Mercury Using 4-(Dimethylamino) Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire Electrode
title_full_unstemmed Flow Injection Analysis of Mercury Using 4-(Dimethylamino) Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire Electrode
title_sort flow injection analysis of mercury using 4-(dimethylamino) benzaldehyde-4-ethylthiosemicarbazone as the ionophore of a coated wire electrode
publisher MDPI AG
series Sensors
issn 1424-8220
publishDate 2012-11-01
description A flow injection analysis (FIA) incorporating a thiosemicarbazone-based coated wire electrode (CWE) was developed method for the determination of mercury(II). A 0.1 M KNO3 carrier stream with pH between 1 and 5 and flow rate of 1 mL·min−1 were used as optimum parameters. A linear plot within the concentration range of 5 × 10−6–0.1 M Hg(II), slope of 27.8 ± 1 mV per decade and correlation coefficient (R2) of 0.984 were obtained. The system was successfully applied for the determination of mercury(II) in dental amalgam solutions and spiked environmental water samples. Highly reproducible measurements with relative standard deviation (RSD < 1% (n = 3)) were obtained, giving a typical throughput of 30 samples·h−1.
topic coated wire electrode
4-(dimethylamino) benzaldehyde-4-ethylthiosemicarbazone
mercury(II) ion-selective electrode
flow injection analysis
url http://www.mdpi.com/1424-8220/12/11/14968
work_keys_str_mv AT sulaimanabghani flowinjectionanalysisofmercuryusing4dimethylaminobenzaldehyde4ethylthiosemicarbazoneastheionophoreofacoatedwireelectrode
AT abdussalamsalhin flowinjectionanalysisofmercuryusing4dimethylaminobenzaldehyde4ethylthiosemicarbazoneastheionophoreofacoatedwireelectrode
AT taraftahir flowinjectionanalysisofmercuryusing4dimethylaminobenzaldehyde4ethylthiosemicarbazoneastheionophoreofacoatedwireelectrode
_version_ 1725761255623360512