Flow Injection Analysis of Mercury Using 4-(Dimethylamino) Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire Electrode
A flow injection analysis (FIA) incorporating a thiosemicarbazone-based coated wire electrode (CWE) was developed method for the determination of mercury(II). A 0.1 M KNO3 carrier stream with pH between 1 and 5 and flow rate of 1 mL·min−1 were used as optimum parameters. A...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2012-11-01
|
Series: | Sensors |
Subjects: | |
Online Access: | http://www.mdpi.com/1424-8220/12/11/14968 |
id |
doaj-1807747f5923447b8f64a26ff6bb3114 |
---|---|
record_format |
Article |
spelling |
doaj-1807747f5923447b8f64a26ff6bb31142020-11-24T22:24:27ZengMDPI AGSensors1424-82202012-11-011211149681498210.3390/s121114968Flow Injection Analysis of Mercury Using 4-(Dimethylamino) Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire ElectrodeSulaiman Ab GhaniAbdussalam SalhinTara F. TahirA flow injection analysis (FIA) incorporating a thiosemicarbazone-based coated wire electrode (CWE) was developed method for the determination of mercury(II). A 0.1 M KNO3 carrier stream with pH between 1 and 5 and flow rate of 1 mL·min−1 were used as optimum parameters. A linear plot within the concentration range of 5 × 10−6–0.1 M Hg(II), slope of 27.8 ± 1 mV per decade and correlation coefficient (R2) of 0.984 were obtained. The system was successfully applied for the determination of mercury(II) in dental amalgam solutions and spiked environmental water samples. Highly reproducible measurements with relative standard deviation (RSD < 1% (n = 3)) were obtained, giving a typical throughput of 30 samples·h−1.http://www.mdpi.com/1424-8220/12/11/14968coated wire electrode4-(dimethylamino) benzaldehyde-4-ethylthiosemicarbazonemercury(II) ion-selective electrodeflow injection analysis |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Sulaiman Ab Ghani Abdussalam Salhin Tara F. Tahir |
spellingShingle |
Sulaiman Ab Ghani Abdussalam Salhin Tara F. Tahir Flow Injection Analysis of Mercury Using 4-(Dimethylamino) Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire Electrode Sensors coated wire electrode 4-(dimethylamino) benzaldehyde-4-ethylthiosemicarbazone mercury(II) ion-selective electrode flow injection analysis |
author_facet |
Sulaiman Ab Ghani Abdussalam Salhin Tara F. Tahir |
author_sort |
Sulaiman Ab Ghani |
title |
Flow Injection Analysis of Mercury Using 4-(Dimethylamino) Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire Electrode |
title_short |
Flow Injection Analysis of Mercury Using 4-(Dimethylamino) Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire Electrode |
title_full |
Flow Injection Analysis of Mercury Using 4-(Dimethylamino) Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire Electrode |
title_fullStr |
Flow Injection Analysis of Mercury Using 4-(Dimethylamino) Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire Electrode |
title_full_unstemmed |
Flow Injection Analysis of Mercury Using 4-(Dimethylamino) Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire Electrode |
title_sort |
flow injection analysis of mercury using 4-(dimethylamino) benzaldehyde-4-ethylthiosemicarbazone as the ionophore of a coated wire electrode |
publisher |
MDPI AG |
series |
Sensors |
issn |
1424-8220 |
publishDate |
2012-11-01 |
description |
A flow injection analysis (FIA) incorporating a thiosemicarbazone-based coated wire electrode (CWE) was developed method for the determination of mercury(II). A 0.1 M KNO3 carrier stream with pH between 1 and 5 and flow rate of 1 mL·min−1 were used as optimum parameters. A linear plot within the concentration range of 5 × 10−6–0.1 M Hg(II), slope of 27.8 ± 1 mV per decade and correlation coefficient (R2) of 0.984 were obtained. The system was successfully applied for the determination of mercury(II) in dental amalgam solutions and spiked environmental water samples. Highly reproducible measurements with relative standard deviation (RSD < 1% (n = 3)) were obtained, giving a typical throughput of 30 samples·h−1. |
topic |
coated wire electrode 4-(dimethylamino) benzaldehyde-4-ethylthiosemicarbazone mercury(II) ion-selective electrode flow injection analysis |
url |
http://www.mdpi.com/1424-8220/12/11/14968 |
work_keys_str_mv |
AT sulaimanabghani flowinjectionanalysisofmercuryusing4dimethylaminobenzaldehyde4ethylthiosemicarbazoneastheionophoreofacoatedwireelectrode AT abdussalamsalhin flowinjectionanalysisofmercuryusing4dimethylaminobenzaldehyde4ethylthiosemicarbazoneastheionophoreofacoatedwireelectrode AT taraftahir flowinjectionanalysisofmercuryusing4dimethylaminobenzaldehyde4ethylthiosemicarbazoneastheionophoreofacoatedwireelectrode |
_version_ |
1725761255623360512 |