Analysis the macular ganglion cell complex thickness in monocular strabismic amblyopia patients by Fourier-domain OCT
AIM: To detect the macular ganglion cell complex thickness in monocular strabismus amblyopia patients, in order to explore the relationship between the degree of amblyopia and retinal ganglion cell complex thickness, and found out whether there is abnormal macular ganglion cell structure in strabism...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Press of International Journal of Ophthalmology (IJO PRESS)
2014-11-01
|
Series: | Guoji Yanke Zazhi |
Subjects: | |
Online Access: | http://ies.ijo.cn/cn_publish/2014/11/201411026.pdf |
id |
doaj-1a737dd8ee42410eb1fbfcc78a484296 |
---|---|
record_format |
Article |
spelling |
doaj-1a737dd8ee42410eb1fbfcc78a4842962020-11-24T23:04:26ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51231672-51232014-11-0114112012201510.3980/j.issn.1672-5123.2014.11.26Analysis the macular ganglion cell complex thickness in monocular strabismic amblyopia patients by Fourier-domain OCTHong-Wei Deng0Hui-Ting Xie1Hui-Li Jia2Shenzhen Eye Hospital Affiliated to Jinan University, Shenzhen 518001, Guangdong Province, ChinaShenzhen Eye Hospital Affiliated to Jinan University, Shenzhen 518001, Guangdong Province, ChinaShenzhen Eye Hospital Affiliated to Jinan University, Shenzhen 518001, Guangdong Province, ChinaAIM: To detect the macular ganglion cell complex thickness in monocular strabismus amblyopia patients, in order to explore the relationship between the degree of amblyopia and retinal ganglion cell complex thickness, and found out whether there is abnormal macular ganglion cell structure in strabismic amblyopia. <p>METHODS: Using a fourier-domain optical coherence tomography(FD-OCT)instrument iVue<sup>&</sup>#xAE;(Optovue Inc, Fremont, CA), Macular ganglion cell complex(mGCC)thickness was measured and statistical the relation rate with the best vision acuity correction was compared Gman among 26 patients(52 eyes)included in this study. <p>RESULTS: The mean thickness of the mGCC in macular was investigated into three parts: centrial, inner circle(3mm)and outer circle(6mm). The mean thicknesses of mGCC in central, inner and outer circle was 50.74±21.51μm, 101.4±8.51μm, 114.2±9.455μm in the strabismic amblyopia eyes(SAE), and 43.79±11.92μm,92.47±25.01μm, 113.3±12.88μm in the contralateral sound eyes(CSE)respectively. There was no statistically significant difference among the eyes(<i>P</i>>0.05). But the best corrected vision acuity had a good correlation rate between mGcc thicknesses, which was better relative for the lower part than the upper part.<p>CONCLUSION:There is a relationship between the amblyopia vision acuity and the mGCC thickness. Although there has not statistically significant difference of the mGCC thickness compared with the SAE and CSE. To measure the macular center mGCC thickness in clinic may understand the degree of amblyopia.http://ies.ijo.cn/cn_publish/2014/11/201411026.pdfstrabismic amblyopiaretinal pigmented epitheliummaculaganglion cell complex thickness |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Hong-Wei Deng Hui-Ting Xie Hui-Li Jia |
spellingShingle |
Hong-Wei Deng Hui-Ting Xie Hui-Li Jia Analysis the macular ganglion cell complex thickness in monocular strabismic amblyopia patients by Fourier-domain OCT Guoji Yanke Zazhi strabismic amblyopia retinal pigmented epithelium macula ganglion cell complex thickness |
author_facet |
Hong-Wei Deng Hui-Ting Xie Hui-Li Jia |
author_sort |
Hong-Wei Deng |
title |
Analysis the macular ganglion cell complex thickness in monocular strabismic amblyopia patients by Fourier-domain OCT |
title_short |
Analysis the macular ganglion cell complex thickness in monocular strabismic amblyopia patients by Fourier-domain OCT |
title_full |
Analysis the macular ganglion cell complex thickness in monocular strabismic amblyopia patients by Fourier-domain OCT |
title_fullStr |
Analysis the macular ganglion cell complex thickness in monocular strabismic amblyopia patients by Fourier-domain OCT |
title_full_unstemmed |
Analysis the macular ganglion cell complex thickness in monocular strabismic amblyopia patients by Fourier-domain OCT |
title_sort |
analysis the macular ganglion cell complex thickness in monocular strabismic amblyopia patients by fourier-domain oct |
publisher |
Press of International Journal of Ophthalmology (IJO PRESS) |
series |
Guoji Yanke Zazhi |
issn |
1672-5123 1672-5123 |
publishDate |
2014-11-01 |
description |
AIM: To detect the macular ganglion cell complex thickness in monocular strabismus amblyopia patients, in order to explore the relationship between the degree of amblyopia and retinal ganglion cell complex thickness, and found out whether there is abnormal macular ganglion cell structure in strabismic amblyopia. <p>METHODS: Using a fourier-domain optical coherence tomography(FD-OCT)instrument iVue<sup>&</sup>#xAE;(Optovue Inc, Fremont, CA), Macular ganglion cell complex(mGCC)thickness was measured and statistical the relation rate with the best vision acuity correction was compared Gman among 26 patients(52 eyes)included in this study. <p>RESULTS: The mean thickness of the mGCC in macular was investigated into three parts: centrial, inner circle(3mm)and outer circle(6mm). The mean thicknesses of mGCC in central, inner and outer circle was 50.74±21.51μm, 101.4±8.51μm, 114.2±9.455μm in the strabismic amblyopia eyes(SAE), and 43.79±11.92μm,92.47±25.01μm, 113.3±12.88μm in the contralateral sound eyes(CSE)respectively. There was no statistically significant difference among the eyes(<i>P</i>>0.05). But the best corrected vision acuity had a good correlation rate between mGcc thicknesses, which was better relative for the lower part than the upper part.<p>CONCLUSION:There is a relationship between the amblyopia vision acuity and the mGCC thickness. Although there has not statistically significant difference of the mGCC thickness compared with the SAE and CSE. To measure the macular center mGCC thickness in clinic may understand the degree of amblyopia. |
topic |
strabismic amblyopia retinal pigmented epithelium macula ganglion cell complex thickness |
url |
http://ies.ijo.cn/cn_publish/2014/11/201411026.pdf |
work_keys_str_mv |
AT hongweideng analysisthemacularganglioncellcomplexthicknessinmonocularstrabismicamblyopiapatientsbyfourierdomainoct AT huitingxie analysisthemacularganglioncellcomplexthicknessinmonocularstrabismicamblyopiapatientsbyfourierdomainoct AT huilijia analysisthemacularganglioncellcomplexthicknessinmonocularstrabismicamblyopiapatientsbyfourierdomainoct |
_version_ |
1725630420301643776 |