Analysis the macular ganglion cell complex thickness in monocular strabismic amblyopia patients by Fourier-domain OCT

AIM: To detect the macular ganglion cell complex thickness in monocular strabismus amblyopia patients, in order to explore the relationship between the degree of amblyopia and retinal ganglion cell complex thickness, and found out whether there is abnormal macular ganglion cell structure in strabism...

Full description

Bibliographic Details
Main Authors: Hong-Wei Deng, Hui-Ting Xie, Hui-Li Jia
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2014-11-01
Series:Guoji Yanke Zazhi
Subjects:
Online Access:http://ies.ijo.cn/cn_publish/2014/11/201411026.pdf
id doaj-1a737dd8ee42410eb1fbfcc78a484296
record_format Article
spelling doaj-1a737dd8ee42410eb1fbfcc78a4842962020-11-24T23:04:26ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51231672-51232014-11-0114112012201510.3980/j.issn.1672-5123.2014.11.26Analysis the macular ganglion cell complex thickness in monocular strabismic amblyopia patients by Fourier-domain OCTHong-Wei Deng0Hui-Ting Xie1Hui-Li Jia2Shenzhen Eye Hospital Affiliated to Jinan University, Shenzhen 518001, Guangdong Province, ChinaShenzhen Eye Hospital Affiliated to Jinan University, Shenzhen 518001, Guangdong Province, ChinaShenzhen Eye Hospital Affiliated to Jinan University, Shenzhen 518001, Guangdong Province, ChinaAIM: To detect the macular ganglion cell complex thickness in monocular strabismus amblyopia patients, in order to explore the relationship between the degree of amblyopia and retinal ganglion cell complex thickness, and found out whether there is abnormal macular ganglion cell structure in strabismic amblyopia. <p>METHODS: Using a fourier-domain optical coherence tomography(FD-OCT)instrument iVue<sup>&</sup>#xAE;(Optovue Inc, Fremont, CA), Macular ganglion cell complex(mGCC)thickness was measured and statistical the relation rate with the best vision acuity correction was compared Gman among 26 patients(52 eyes)included in this study. <p>RESULTS: The mean thickness of the mGCC in macular was investigated into three parts: centrial, inner circle(3mm)and outer circle(6mm). The mean thicknesses of mGCC in central, inner and outer circle was 50.74±21.51μm, 101.4±8.51μm, 114.2±9.455μm in the strabismic amblyopia eyes(SAE), and 43.79±11.92μm,92.47±25.01μm, 113.3±12.88μm in the contralateral sound eyes(CSE)respectively. There was no statistically significant difference among the eyes(<i>P</i>>0.05). But the best corrected vision acuity had a good correlation rate between mGcc thicknesses, which was better relative for the lower part than the upper part.<p>CONCLUSION:There is a relationship between the amblyopia vision acuity and the mGCC thickness. Although there has not statistically significant difference of the mGCC thickness compared with the SAE and CSE. To measure the macular center mGCC thickness in clinic may understand the degree of amblyopia.http://ies.ijo.cn/cn_publish/2014/11/201411026.pdfstrabismic amblyopiaretinal pigmented epitheliummaculaganglion cell complex thickness
collection DOAJ
language English
format Article
sources DOAJ
author Hong-Wei Deng
Hui-Ting Xie
Hui-Li Jia
spellingShingle Hong-Wei Deng
Hui-Ting Xie
Hui-Li Jia
Analysis the macular ganglion cell complex thickness in monocular strabismic amblyopia patients by Fourier-domain OCT
Guoji Yanke Zazhi
strabismic amblyopia
retinal pigmented epithelium
macula
ganglion cell complex thickness
author_facet Hong-Wei Deng
Hui-Ting Xie
Hui-Li Jia
author_sort Hong-Wei Deng
title Analysis the macular ganglion cell complex thickness in monocular strabismic amblyopia patients by Fourier-domain OCT
title_short Analysis the macular ganglion cell complex thickness in monocular strabismic amblyopia patients by Fourier-domain OCT
title_full Analysis the macular ganglion cell complex thickness in monocular strabismic amblyopia patients by Fourier-domain OCT
title_fullStr Analysis the macular ganglion cell complex thickness in monocular strabismic amblyopia patients by Fourier-domain OCT
title_full_unstemmed Analysis the macular ganglion cell complex thickness in monocular strabismic amblyopia patients by Fourier-domain OCT
title_sort analysis the macular ganglion cell complex thickness in monocular strabismic amblyopia patients by fourier-domain oct
publisher Press of International Journal of Ophthalmology (IJO PRESS)
series Guoji Yanke Zazhi
issn 1672-5123
1672-5123
publishDate 2014-11-01
description AIM: To detect the macular ganglion cell complex thickness in monocular strabismus amblyopia patients, in order to explore the relationship between the degree of amblyopia and retinal ganglion cell complex thickness, and found out whether there is abnormal macular ganglion cell structure in strabismic amblyopia. <p>METHODS: Using a fourier-domain optical coherence tomography(FD-OCT)instrument iVue<sup>&</sup>#xAE;(Optovue Inc, Fremont, CA), Macular ganglion cell complex(mGCC)thickness was measured and statistical the relation rate with the best vision acuity correction was compared Gman among 26 patients(52 eyes)included in this study. <p>RESULTS: The mean thickness of the mGCC in macular was investigated into three parts: centrial, inner circle(3mm)and outer circle(6mm). The mean thicknesses of mGCC in central, inner and outer circle was 50.74±21.51μm, 101.4±8.51μm, 114.2±9.455μm in the strabismic amblyopia eyes(SAE), and 43.79±11.92μm,92.47±25.01μm, 113.3±12.88μm in the contralateral sound eyes(CSE)respectively. There was no statistically significant difference among the eyes(<i>P</i>>0.05). But the best corrected vision acuity had a good correlation rate between mGcc thicknesses, which was better relative for the lower part than the upper part.<p>CONCLUSION:There is a relationship between the amblyopia vision acuity and the mGCC thickness. Although there has not statistically significant difference of the mGCC thickness compared with the SAE and CSE. To measure the macular center mGCC thickness in clinic may understand the degree of amblyopia.
topic strabismic amblyopia
retinal pigmented epithelium
macula
ganglion cell complex thickness
url http://ies.ijo.cn/cn_publish/2014/11/201411026.pdf
work_keys_str_mv AT hongweideng analysisthemacularganglioncellcomplexthicknessinmonocularstrabismicamblyopiapatientsbyfourierdomainoct
AT huitingxie analysisthemacularganglioncellcomplexthicknessinmonocularstrabismicamblyopiapatientsbyfourierdomainoct
AT huilijia analysisthemacularganglioncellcomplexthicknessinmonocularstrabismicamblyopiapatientsbyfourierdomainoct
_version_ 1725630420301643776