An Analysis of Data Acquisition System of Temperature, Oxygen, and Carbon Dioxide in Refrigerator with Arduino Mega 2560
The influence of storage room conditions can cause the quality of post-harvest fruit to decline, so monitoring is necessary. Monitoring is carried out using a data acquisition system designed to measure the temperature, oxygen, and carbon dioxide in the refrigerator storage room automatically. Syste...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | Indonesian |
Published: |
Institut Agama Islam Negeri Raden Intan Lampung
2021-04-01
|
Series: | Jurnal Ilmiah Pendidikan Fisika Al-Biruni |
Subjects: | |
Online Access: | http://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/7452 |
id |
doaj-1b005ccfa96b482c8c828f0564e3812e |
---|---|
record_format |
Article |
spelling |
doaj-1b005ccfa96b482c8c828f0564e3812e2021-09-15T04:34:07ZindInstitut Agama Islam Negeri Raden Intan LampungJurnal Ilmiah Pendidikan Fisika Al-Biruni2303-18322503-023X2021-04-0110111912710.24042/jipfalbiruni.v10i1.74523873An Analysis of Data Acquisition System of Temperature, Oxygen, and Carbon Dioxide in Refrigerator with Arduino Mega 2560Sri Wahyu Suciyati0Muhammad Syarif Hidayatullah1Gurum Ahmad Pauzi2University of LampungUniversity of LampungUniversity of LampungThe influence of storage room conditions can cause the quality of post-harvest fruit to decline, so monitoring is necessary. Monitoring is carried out using a data acquisition system designed to measure the temperature, oxygen, and carbon dioxide in the refrigerator storage room automatically. System design is divided into two stages, namely hardware design and software design. The hardware is composed of a sensor unit, a data processing unit (Arduino Mega 2560), and a display unit. On the other hand, the software uses the Arduino IDE. The test results of temperature (DS18B20), oxygen (Figaro KE-25), and carbon dioxide (MH-Z14a) from the system obtained an accuracy value of 98.29% with an error of 1.71%; 98.57% with an error of 1.43%, and 94.58% with an error of 5.42%. The device can display real-time measurement data output to 20x4 LCD with IIC and save the data on a micro-SD card.http://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/7452data acquisitionarduinotemperatureoxygen sensorcarbon dioxide sensor |
collection |
DOAJ |
language |
Indonesian |
format |
Article |
sources |
DOAJ |
author |
Sri Wahyu Suciyati Muhammad Syarif Hidayatullah Gurum Ahmad Pauzi |
spellingShingle |
Sri Wahyu Suciyati Muhammad Syarif Hidayatullah Gurum Ahmad Pauzi An Analysis of Data Acquisition System of Temperature, Oxygen, and Carbon Dioxide in Refrigerator with Arduino Mega 2560 Jurnal Ilmiah Pendidikan Fisika Al-Biruni data acquisition arduino temperature oxygen sensor carbon dioxide sensor |
author_facet |
Sri Wahyu Suciyati Muhammad Syarif Hidayatullah Gurum Ahmad Pauzi |
author_sort |
Sri Wahyu Suciyati |
title |
An Analysis of Data Acquisition System of Temperature, Oxygen, and Carbon Dioxide in Refrigerator with Arduino Mega 2560 |
title_short |
An Analysis of Data Acquisition System of Temperature, Oxygen, and Carbon Dioxide in Refrigerator with Arduino Mega 2560 |
title_full |
An Analysis of Data Acquisition System of Temperature, Oxygen, and Carbon Dioxide in Refrigerator with Arduino Mega 2560 |
title_fullStr |
An Analysis of Data Acquisition System of Temperature, Oxygen, and Carbon Dioxide in Refrigerator with Arduino Mega 2560 |
title_full_unstemmed |
An Analysis of Data Acquisition System of Temperature, Oxygen, and Carbon Dioxide in Refrigerator with Arduino Mega 2560 |
title_sort |
analysis of data acquisition system of temperature, oxygen, and carbon dioxide in refrigerator with arduino mega 2560 |
publisher |
Institut Agama Islam Negeri Raden Intan Lampung |
series |
Jurnal Ilmiah Pendidikan Fisika Al-Biruni |
issn |
2303-1832 2503-023X |
publishDate |
2021-04-01 |
description |
The influence of storage room conditions can cause the quality of post-harvest fruit to decline, so monitoring is necessary. Monitoring is carried out using a data acquisition system designed to measure the temperature, oxygen, and carbon dioxide in the refrigerator storage room automatically. System design is divided into two stages, namely hardware design and software design. The hardware is composed of a sensor unit, a data processing unit (Arduino Mega 2560), and a display unit. On the other hand, the software uses the Arduino IDE. The test results of temperature (DS18B20), oxygen (Figaro KE-25), and carbon dioxide (MH-Z14a) from the system obtained an accuracy value of 98.29% with an error of 1.71%; 98.57% with an error of 1.43%, and 94.58% with an error of 5.42%. The device can display real-time measurement data output to 20x4 LCD with IIC and save the data on a micro-SD card. |
topic |
data acquisition arduino temperature oxygen sensor carbon dioxide sensor |
url |
http://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/7452 |
work_keys_str_mv |
AT sriwahyusuciyati ananalysisofdataacquisitionsystemoftemperatureoxygenandcarbondioxideinrefrigeratorwitharduinomega2560 AT muhammadsyarifhidayatullah ananalysisofdataacquisitionsystemoftemperatureoxygenandcarbondioxideinrefrigeratorwitharduinomega2560 AT gurumahmadpauzi ananalysisofdataacquisitionsystemoftemperatureoxygenandcarbondioxideinrefrigeratorwitharduinomega2560 AT sriwahyusuciyati analysisofdataacquisitionsystemoftemperatureoxygenandcarbondioxideinrefrigeratorwitharduinomega2560 AT muhammadsyarifhidayatullah analysisofdataacquisitionsystemoftemperatureoxygenandcarbondioxideinrefrigeratorwitharduinomega2560 AT gurumahmadpauzi analysisofdataacquisitionsystemoftemperatureoxygenandcarbondioxideinrefrigeratorwitharduinomega2560 |
_version_ |
1717379293688889344 |