Comparison of two immunoassay systems for hCGβ and PAPP-A in prenatal screening for trisomy 21, 18, and 13 in the first trimester

Objectives: The biochemical serum markers free β-human chorionic gonadotropin (hCGβ) and pregnancy associated plasma protein A (PAPP-A), used in screening for trisomy 21 (T21), trisomy 18 (T18), and trisomy 13 (T13) during the first trimester, can be measured on different laboratory instruments e.g....

Full description

Bibliographic Details
Main Authors: Anna Elise Engell, Elin Rebecka Carlsson, Finn Stener Jørgensen, Steen Sørensen
Format: Article
Language:English
Published: Elsevier 2017-12-01
Series:Practical Laboratory Medicine
Online Access:http://www.sciencedirect.com/science/article/pii/S2352551717300070
id doaj-1c9aabb4732d48c7baa05019e36c1ede
record_format Article
spelling doaj-1c9aabb4732d48c7baa05019e36c1ede2020-11-25T00:13:24ZengElsevierPractical Laboratory Medicine2352-55172017-12-0191823Comparison of two immunoassay systems for hCGβ and PAPP-A in prenatal screening for trisomy 21, 18, and 13 in the first trimesterAnna Elise Engell0Elin Rebecka Carlsson1Finn Stener Jørgensen2Steen Sørensen3Department of Clinical Biochemistry, Copenhagen University Hospital Hvidovre, Denmark; Corresponding author.Department of Clinical Biochemistry, Copenhagen University Hospital Hvidovre, DenmarkFetal Medicine Unit, Department of Obstetrics and Gynaecology, Copenhagen University Hospital Hvidovre, DenmarkDepartment of Clinical Biochemistry, Copenhagen University Hospital Hvidovre, Denmark; Clinical Research Centre, Copenhagen University Hospital Hvidovre, DenmarkObjectives: The biochemical serum markers free β-human chorionic gonadotropin (hCGβ) and pregnancy associated plasma protein A (PAPP-A), used in screening for trisomy 21 (T21), trisomy 18 (T18), and trisomy 13 (T13) during the first trimester, can be measured on different laboratory instruments e.g. Kryptor (Brahms) and Cobas (Roche). We compared the performance of these two analytical instruments when used for first trimester combined testing. Design and methods: Serum samples from 944 singleton pregnant women attending for first trimester combined testing were routinely assayed for hCGβ and PAPP-A on Kryptor, and re-analyzed on Cobas. In addition, serum samples from 70 pregnant women carrying a fetus affected by T21, T18 or T13, were re-assayed on Cobas. Results: For the screening population, the hCGβ and PAPP-A results in multiples of the median (MoM) from Kryptor and Cobas were significantly lower on Cobas when compared to Kryptor. The number of pregnant women with a risk above 1:300 for T21 was 48 for both Cobas and Kryptor, although a few patients only had a high risk with one of the methods. Overall, the screen positive rate was 5.1% for both instruments. In the trisomy groups the calculated risks for T21, T18, and T13 agreed well between Cobas and Kryptor. Conclusions: The screen positive rate for T21 (5.1%) did not differ between the two analytical platforms in our screening population, although PAPP-A measurements form Cobas were significantly lower than those from Kryptor. The calculated risks for the pregnancies affected by trisomies using hCGβ MoM and PAPP-A MoM from Kryptor agreed well with those from Cobas. Keywords: Aneuploidy, Combined first trimester screening, First trimester risk assessment, Free β-human chorionic gonadotropin (hCGβ), Pregnancy associated plasma protein-A (PAPP-A), Trisomy screeninghttp://www.sciencedirect.com/science/article/pii/S2352551717300070
collection DOAJ
language English
format Article
sources DOAJ
author Anna Elise Engell
Elin Rebecka Carlsson
Finn Stener Jørgensen
Steen Sørensen
spellingShingle Anna Elise Engell
Elin Rebecka Carlsson
Finn Stener Jørgensen
Steen Sørensen
Comparison of two immunoassay systems for hCGβ and PAPP-A in prenatal screening for trisomy 21, 18, and 13 in the first trimester
Practical Laboratory Medicine
author_facet Anna Elise Engell
Elin Rebecka Carlsson
Finn Stener Jørgensen
Steen Sørensen
author_sort Anna Elise Engell
title Comparison of two immunoassay systems for hCGβ and PAPP-A in prenatal screening for trisomy 21, 18, and 13 in the first trimester
title_short Comparison of two immunoassay systems for hCGβ and PAPP-A in prenatal screening for trisomy 21, 18, and 13 in the first trimester
title_full Comparison of two immunoassay systems for hCGβ and PAPP-A in prenatal screening for trisomy 21, 18, and 13 in the first trimester
title_fullStr Comparison of two immunoassay systems for hCGβ and PAPP-A in prenatal screening for trisomy 21, 18, and 13 in the first trimester
title_full_unstemmed Comparison of two immunoassay systems for hCGβ and PAPP-A in prenatal screening for trisomy 21, 18, and 13 in the first trimester
title_sort comparison of two immunoassay systems for hcgβ and papp-a in prenatal screening for trisomy 21, 18, and 13 in the first trimester
publisher Elsevier
series Practical Laboratory Medicine
issn 2352-5517
publishDate 2017-12-01
description Objectives: The biochemical serum markers free β-human chorionic gonadotropin (hCGβ) and pregnancy associated plasma protein A (PAPP-A), used in screening for trisomy 21 (T21), trisomy 18 (T18), and trisomy 13 (T13) during the first trimester, can be measured on different laboratory instruments e.g. Kryptor (Brahms) and Cobas (Roche). We compared the performance of these two analytical instruments when used for first trimester combined testing. Design and methods: Serum samples from 944 singleton pregnant women attending for first trimester combined testing were routinely assayed for hCGβ and PAPP-A on Kryptor, and re-analyzed on Cobas. In addition, serum samples from 70 pregnant women carrying a fetus affected by T21, T18 or T13, were re-assayed on Cobas. Results: For the screening population, the hCGβ and PAPP-A results in multiples of the median (MoM) from Kryptor and Cobas were significantly lower on Cobas when compared to Kryptor. The number of pregnant women with a risk above 1:300 for T21 was 48 for both Cobas and Kryptor, although a few patients only had a high risk with one of the methods. Overall, the screen positive rate was 5.1% for both instruments. In the trisomy groups the calculated risks for T21, T18, and T13 agreed well between Cobas and Kryptor. Conclusions: The screen positive rate for T21 (5.1%) did not differ between the two analytical platforms in our screening population, although PAPP-A measurements form Cobas were significantly lower than those from Kryptor. The calculated risks for the pregnancies affected by trisomies using hCGβ MoM and PAPP-A MoM from Kryptor agreed well with those from Cobas. Keywords: Aneuploidy, Combined first trimester screening, First trimester risk assessment, Free β-human chorionic gonadotropin (hCGβ), Pregnancy associated plasma protein-A (PAPP-A), Trisomy screening
url http://www.sciencedirect.com/science/article/pii/S2352551717300070
work_keys_str_mv AT annaeliseengell comparisonoftwoimmunoassaysystemsforhcgbandpappainprenatalscreeningfortrisomy2118and13inthefirsttrimester
AT elinrebeckacarlsson comparisonoftwoimmunoassaysystemsforhcgbandpappainprenatalscreeningfortrisomy2118and13inthefirsttrimester
AT finnstenerjørgensen comparisonoftwoimmunoassaysystemsforhcgbandpappainprenatalscreeningfortrisomy2118and13inthefirsttrimester
AT steensørensen comparisonoftwoimmunoassaysystemsforhcgbandpappainprenatalscreeningfortrisomy2118and13inthefirsttrimester
_version_ 1725394440270381056