A New Automated Way to Measure Polyethylene Wear in THA Using a High Resolution CT Scanner: Method and Analysis
As the most advantageous total hip arthroplasty (THA) operation is the first, timely replacement of only the liner is socially and economically important because the utilization of THA is increasing as younger and more active patients are receiving implants and they are living longer. Automatic algo...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2014-01-01
|
Series: | The Scientific World Journal |
Online Access: | http://dx.doi.org/10.1155/2014/528407 |
id |
doaj-1cdbb87ec63543baae0a130067e2228b |
---|---|
record_format |
Article |
spelling |
doaj-1cdbb87ec63543baae0a130067e2228b2020-11-25T01:57:02ZengHindawi LimitedThe Scientific World Journal2356-61401537-744X2014-01-01201410.1155/2014/528407528407A New Automated Way to Measure Polyethylene Wear in THA Using a High Resolution CT Scanner: Method and AnalysisGerald Q. Maguire Jr.0Marilyn E. Noz1Henrik Olivecrona2Michael P. Zeleznik3Lars Weidenhielm4School of Information and Communication Technology, KTH Royal Institute of Technology, Isafjordsgatan 26, 418 164-40 Stockholm, SwedenDepartment of Radiology, New York University, 550 First Avenue TSHW232, New York, NY 10016, USADepartment of Molecular Medicine and Surgery, Section of Orthopaedics and Sports Medicine, Karolinska Institute, A2:07, 171 76 Stockholm, SwedenSchool of Computing, University of Utah, College of Engineering, 50 Central Campus Dr., Room 3190, Salt Lake City, UT 84112, USADepartment of Molecular Medicine and Surgery, Section of Orthopaedics and Sports Medicine, Karolinska Institute, A2:07, 171 76 Stockholm, SwedenAs the most advantageous total hip arthroplasty (THA) operation is the first, timely replacement of only the liner is socially and economically important because the utilization of THA is increasing as younger and more active patients are receiving implants and they are living longer. Automatic algorithms were developed to infer liner wear by estimating the separation between the acetabular cup and femoral component head given a computed tomography (CT) volume. Two series of CT volumes of a hip phantom were acquired with the femoral component head placed at 14 different positions relative to the acetabular cup. The mean and standard deviation (SD) of the diameter of the acetabular cup and femoral component head, in addition to the range of error in the expected wear values and the repeatability of all the measurements, were calculated. The algorithms resulted in a mean (±SD) for the diameter of the acetabular cup of 54.21 (±0.011) mm and for the femoral component head of 22.09 (±0.02) mm. The wear error was ±0.1 mm and the repeatability was 0.077 mm. This approach is applicable clinically as it utilizes readily available computed tomography imaging systems and requires only five minutes of human interaction.http://dx.doi.org/10.1155/2014/528407 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Gerald Q. Maguire Jr. Marilyn E. Noz Henrik Olivecrona Michael P. Zeleznik Lars Weidenhielm |
spellingShingle |
Gerald Q. Maguire Jr. Marilyn E. Noz Henrik Olivecrona Michael P. Zeleznik Lars Weidenhielm A New Automated Way to Measure Polyethylene Wear in THA Using a High Resolution CT Scanner: Method and Analysis The Scientific World Journal |
author_facet |
Gerald Q. Maguire Jr. Marilyn E. Noz Henrik Olivecrona Michael P. Zeleznik Lars Weidenhielm |
author_sort |
Gerald Q. Maguire Jr. |
title |
A New Automated Way to Measure Polyethylene Wear in THA Using a High Resolution CT Scanner: Method and Analysis |
title_short |
A New Automated Way to Measure Polyethylene Wear in THA Using a High Resolution CT Scanner: Method and Analysis |
title_full |
A New Automated Way to Measure Polyethylene Wear in THA Using a High Resolution CT Scanner: Method and Analysis |
title_fullStr |
A New Automated Way to Measure Polyethylene Wear in THA Using a High Resolution CT Scanner: Method and Analysis |
title_full_unstemmed |
A New Automated Way to Measure Polyethylene Wear in THA Using a High Resolution CT Scanner: Method and Analysis |
title_sort |
new automated way to measure polyethylene wear in tha using a high resolution ct scanner: method and analysis |
publisher |
Hindawi Limited |
series |
The Scientific World Journal |
issn |
2356-6140 1537-744X |
publishDate |
2014-01-01 |
description |
As the most advantageous total hip arthroplasty (THA) operation is the first, timely replacement of only the liner is socially and economically important because the utilization of THA is increasing as younger and more active patients are receiving implants and they are living longer. Automatic algorithms were developed to infer liner wear by estimating the separation between the acetabular cup and femoral component head given a computed tomography (CT) volume. Two series of CT volumes of a hip phantom were acquired with the femoral component head placed at 14 different positions relative to the acetabular cup. The mean and standard deviation (SD) of the diameter of the acetabular cup and femoral component head, in addition to the range of error in the expected wear values and the repeatability of all the measurements, were calculated. The algorithms resulted in a mean (±SD) for the diameter of the acetabular cup of 54.21 (±0.011) mm and for the femoral component head of 22.09 (±0.02) mm. The wear error was ±0.1 mm and the repeatability was 0.077 mm. This approach is applicable clinically as it utilizes readily available computed tomography imaging systems and requires only five minutes of human interaction. |
url |
http://dx.doi.org/10.1155/2014/528407 |
work_keys_str_mv |
AT geraldqmaguirejr anewautomatedwaytomeasurepolyethylenewearinthausingahighresolutionctscannermethodandanalysis AT marilynenoz anewautomatedwaytomeasurepolyethylenewearinthausingahighresolutionctscannermethodandanalysis AT henrikolivecrona anewautomatedwaytomeasurepolyethylenewearinthausingahighresolutionctscannermethodandanalysis AT michaelpzeleznik anewautomatedwaytomeasurepolyethylenewearinthausingahighresolutionctscannermethodandanalysis AT larsweidenhielm anewautomatedwaytomeasurepolyethylenewearinthausingahighresolutionctscannermethodandanalysis AT geraldqmaguirejr newautomatedwaytomeasurepolyethylenewearinthausingahighresolutionctscannermethodandanalysis AT marilynenoz newautomatedwaytomeasurepolyethylenewearinthausingahighresolutionctscannermethodandanalysis AT henrikolivecrona newautomatedwaytomeasurepolyethylenewearinthausingahighresolutionctscannermethodandanalysis AT michaelpzeleznik newautomatedwaytomeasurepolyethylenewearinthausingahighresolutionctscannermethodandanalysis AT larsweidenhielm newautomatedwaytomeasurepolyethylenewearinthausingahighresolutionctscannermethodandanalysis |
_version_ |
1724976834309783552 |