The Use of Non-Destructive Testing (NDT) to Detect Bed Joint Reinforcement in AAC Masonry

Detecting non-metallic reinforcement made of FRP (Fibre Reinforced Polymers) can be problematic, particularly at the stage of work inspection and constructional evaluation. In contrast to steel reinforcement, detecting non-metallic reinforcement is difficult using NDT (Non-Destructive Testing) techn...

Full description

Bibliographic Details
Main Authors: Łukasz Drobiec, Radosław Jasiński, Wojciech Mazur
Format: Article
Language:English
Published: MDPI AG 2020-07-01
Series:Applied Sciences
Subjects:
Online Access:https://www.mdpi.com/2076-3417/10/13/4645
id doaj-1da3d401a53e4e5d8bebf901659c2bc1
record_format Article
spelling doaj-1da3d401a53e4e5d8bebf901659c2bc12020-11-25T02:53:20ZengMDPI AGApplied Sciences2076-34172020-07-01104645464510.3390/app10134645The Use of Non-Destructive Testing (NDT) to Detect Bed Joint Reinforcement in AAC MasonryŁukasz Drobiec0Radosław Jasiński1Wojciech Mazur2Department of Building Structures, Silesian University of Technology, ul. Akademicka 5, 44-100 Gliwice, PolandDepartment of Building Structures and Laboratory of Civil Engineering Faculty, Silesian University of Technology, ul. Akademicka 5, 44-100 Gliwice, PolandDepartment of Building Structures, Silesian University of Technology, ul. Akademicka 5, 44-100 Gliwice, PolandDetecting non-metallic reinforcement made of FRP (Fibre Reinforced Polymers) can be problematic, particularly at the stage of work inspection and constructional evaluation. In contrast to steel reinforcement, detecting non-metallic reinforcement is difficult using NDT (Non-Destructive Testing) techniques. These difficulties mainly arise from considerably lower density, radiation resistance or electromagnetic impedance and cross-section of rebars when compared to steel reinforcement. Specific problems with the reinforcement detection are experienced in masonry structures, in which reinforcement is laid in bed joints. Measurements are made on a masonry face in the plane perpendicular to the reinforcement plane, and not the parallel one compared to reinforced concrete structures. Thus, the interpretation of results obtained from NDT can be complicated due to many physical phenomena occurring during tests, methods of presenting measurements and their accuracy. This paper compares different testing techniques used to detect non-metallic reinforcement in the masonry wall made of autoclaved aerated concrete (AAC). For the purpose of the tests, fibreglass and basalt meshes, traditional steel trusses and steel wire meshes were placed in bed joints of the masonry wall. An ultrasonic tomography and GPR (Ground-Penetrating Radar) scanner operating within a broad range of frequencies were used for the tests. We also used the electromagnetic device to detect metal meshes. As expected, the tests confirmed problems with detecting the non-metallic reinforcement. Only the radar method was effective in detecting the non-metallic method, whereas other methods failed. The electromagnetic method detected only the steel reinforcement in the masonry.https://www.mdpi.com/2076-3417/10/13/4645rebar locationFRP reinforcementNDT methodsGPR testingultrasonic testingelectromagnetic testing
collection DOAJ
language English
format Article
sources DOAJ
author Łukasz Drobiec
Radosław Jasiński
Wojciech Mazur
spellingShingle Łukasz Drobiec
Radosław Jasiński
Wojciech Mazur
The Use of Non-Destructive Testing (NDT) to Detect Bed Joint Reinforcement in AAC Masonry
Applied Sciences
rebar location
FRP reinforcement
NDT methods
GPR testing
ultrasonic testing
electromagnetic testing
author_facet Łukasz Drobiec
Radosław Jasiński
Wojciech Mazur
author_sort Łukasz Drobiec
title The Use of Non-Destructive Testing (NDT) to Detect Bed Joint Reinforcement in AAC Masonry
title_short The Use of Non-Destructive Testing (NDT) to Detect Bed Joint Reinforcement in AAC Masonry
title_full The Use of Non-Destructive Testing (NDT) to Detect Bed Joint Reinforcement in AAC Masonry
title_fullStr The Use of Non-Destructive Testing (NDT) to Detect Bed Joint Reinforcement in AAC Masonry
title_full_unstemmed The Use of Non-Destructive Testing (NDT) to Detect Bed Joint Reinforcement in AAC Masonry
title_sort use of non-destructive testing (ndt) to detect bed joint reinforcement in aac masonry
publisher MDPI AG
series Applied Sciences
issn 2076-3417
publishDate 2020-07-01
description Detecting non-metallic reinforcement made of FRP (Fibre Reinforced Polymers) can be problematic, particularly at the stage of work inspection and constructional evaluation. In contrast to steel reinforcement, detecting non-metallic reinforcement is difficult using NDT (Non-Destructive Testing) techniques. These difficulties mainly arise from considerably lower density, radiation resistance or electromagnetic impedance and cross-section of rebars when compared to steel reinforcement. Specific problems with the reinforcement detection are experienced in masonry structures, in which reinforcement is laid in bed joints. Measurements are made on a masonry face in the plane perpendicular to the reinforcement plane, and not the parallel one compared to reinforced concrete structures. Thus, the interpretation of results obtained from NDT can be complicated due to many physical phenomena occurring during tests, methods of presenting measurements and their accuracy. This paper compares different testing techniques used to detect non-metallic reinforcement in the masonry wall made of autoclaved aerated concrete (AAC). For the purpose of the tests, fibreglass and basalt meshes, traditional steel trusses and steel wire meshes were placed in bed joints of the masonry wall. An ultrasonic tomography and GPR (Ground-Penetrating Radar) scanner operating within a broad range of frequencies were used for the tests. We also used the electromagnetic device to detect metal meshes. As expected, the tests confirmed problems with detecting the non-metallic reinforcement. Only the radar method was effective in detecting the non-metallic method, whereas other methods failed. The electromagnetic method detected only the steel reinforcement in the masonry.
topic rebar location
FRP reinforcement
NDT methods
GPR testing
ultrasonic testing
electromagnetic testing
url https://www.mdpi.com/2076-3417/10/13/4645
work_keys_str_mv AT łukaszdrobiec theuseofnondestructivetestingndttodetectbedjointreinforcementinaacmasonry
AT radosławjasinski theuseofnondestructivetestingndttodetectbedjointreinforcementinaacmasonry
AT wojciechmazur theuseofnondestructivetestingndttodetectbedjointreinforcementinaacmasonry
AT łukaszdrobiec useofnondestructivetestingndttodetectbedjointreinforcementinaacmasonry
AT radosławjasinski useofnondestructivetestingndttodetectbedjointreinforcementinaacmasonry
AT wojciechmazur useofnondestructivetestingndttodetectbedjointreinforcementinaacmasonry
_version_ 1724725180784181248