A METHOD OF COMPLEX AUTOMATED MONITORING OF UKRAINIAN POWER ENERGY SYSTEM OBJECTS TO INCREASE ITS OPERATION SAFETY

The paper describes an algorithm of the complex automated monitoring of Ukraine’s power energy system, aimed at ensuring safety of its personnel and equipment. This monitoring involves usage of unmanned aerial vehicles (UAVs) for planned and unplanned registration status of power transmission lines...

Full description

Bibliographic Details
Main Authors: Ye.I. Sokol, M.M. Rezinkina, O.G. Gryb, V.I. Vasilchenko, A.A. Zuev, A.V. Bortnikov, E.V. Sosina
Format: Article
Language:English
Published: National Technical University "Kharkiv Polytechnic Institute" 2016-05-01
Series:Електротехніка і електромеханіка
Subjects:
Online Access:http://eie.khpi.edu.ua/article/view/2074-272X.2016.2.12/64359
id doaj-1dcc6a81ae2841a58cb08866dbdb14d4
record_format Article
spelling doaj-1dcc6a81ae2841a58cb08866dbdb14d42021-07-02T07:37:18ZengNational Technical University "Kharkiv Polytechnic Institute"Електротехніка і електромеханіка2074-272X2309-34042016-05-012657010.20998/2074-272X.2016.2.12A METHOD OF COMPLEX AUTOMATED MONITORING OF UKRAINIAN POWER ENERGY SYSTEM OBJECTS TO INCREASE ITS OPERATION SAFETYYe.I. Sokol0M.M. Rezinkina1O.G. Gryb2V.I. Vasilchenko3A.A. Zuev4A.V. Bortnikov5E.V. Sosina6National Technical University «Kharkiv Polytechnic Institute»State Institution «Institute of Technical Problems of Magnetism of the NAS of Ukraine»National Technical University «Kharkiv Polytechnic Institute»NPC «Ukrenergo»National Technical University «Kharkiv Polytechnic Institute»National Technical University «Kharkiv Polytechnic Institute»National Technical University «Kharkiv Polytechnic Institute»The paper describes an algorithm of the complex automated monitoring of Ukraine’s power energy system, aimed at ensuring safety of its personnel and equipment. This monitoring involves usage of unmanned aerial vehicles (UAVs) for planned and unplanned registration status of power transmission lines (PTL) and high-voltage substations (HVS). It is assumed that unscheduled overflights will be made in emergency situations on power lines. With the help of the UAV, pictures of transmission and HVS will be recorded from the air in the optical and infrared ranges, as well as strength of electric (EF) and magnetic (MF) fields will be measured along the route of flight. Usage specially developed software allows to compare the recorded pictures with pre-UAV etalon patterns corresponding to normal operation of investigated transmission lines and the HVSs. Such reference pattern together with the experimentally obtained maps of HVS’s protective grounding will be summarized in a single document – a passport of HVS and PTL. This passport must also contain the measured and calculated values of strength levels of EF and MF in the places where staff of power facilities stay as well as layout of equipment, the most vulnerable to the effects of electromagnetic interference. If necessary, as part of ongoing monitoring, recommendations will be given on the design and location of electromagnetic screens, reducing the levels of electromagnetic interference as well as on location of lightning rods, reducing probability lightning attachment to the objects. The paper presents analytic expressions, which formed the basis of the developed software for calculation of the EF strength in the vicinity of power lines. This software will be used as a base at UAV navigation along the transmission lines, as well as to detect violations in the transmission lines operation. Comparison of distributions of EF strength calculated with the help of the elaborated software with the known literature data has been presented also. The difference between the proposed method of monitoring and the existing methods is full automation of the complex control of a number of parameters characterizing the state of the external power grid facilities, as well as its basic electrical parameters. This will be possible due to usage of specially developed software for recognition of optical and infrared images, as well as pictures of lines of equal EF and MF strengthhttp://eie.khpi.edu.ua/article/view/2074-272X.2016.2.12/64359power lineelectric and magnetic fieldsautomated monitoringunmanned aerial vehicles
collection DOAJ
language English
format Article
sources DOAJ
author Ye.I. Sokol
M.M. Rezinkina
O.G. Gryb
V.I. Vasilchenko
A.A. Zuev
A.V. Bortnikov
E.V. Sosina
spellingShingle Ye.I. Sokol
M.M. Rezinkina
O.G. Gryb
V.I. Vasilchenko
A.A. Zuev
A.V. Bortnikov
E.V. Sosina
A METHOD OF COMPLEX AUTOMATED MONITORING OF UKRAINIAN POWER ENERGY SYSTEM OBJECTS TO INCREASE ITS OPERATION SAFETY
Електротехніка і електромеханіка
power line
electric and magnetic fields
automated monitoring
unmanned aerial vehicles
author_facet Ye.I. Sokol
M.M. Rezinkina
O.G. Gryb
V.I. Vasilchenko
A.A. Zuev
A.V. Bortnikov
E.V. Sosina
author_sort Ye.I. Sokol
title A METHOD OF COMPLEX AUTOMATED MONITORING OF UKRAINIAN POWER ENERGY SYSTEM OBJECTS TO INCREASE ITS OPERATION SAFETY
title_short A METHOD OF COMPLEX AUTOMATED MONITORING OF UKRAINIAN POWER ENERGY SYSTEM OBJECTS TO INCREASE ITS OPERATION SAFETY
title_full A METHOD OF COMPLEX AUTOMATED MONITORING OF UKRAINIAN POWER ENERGY SYSTEM OBJECTS TO INCREASE ITS OPERATION SAFETY
title_fullStr A METHOD OF COMPLEX AUTOMATED MONITORING OF UKRAINIAN POWER ENERGY SYSTEM OBJECTS TO INCREASE ITS OPERATION SAFETY
title_full_unstemmed A METHOD OF COMPLEX AUTOMATED MONITORING OF UKRAINIAN POWER ENERGY SYSTEM OBJECTS TO INCREASE ITS OPERATION SAFETY
title_sort method of complex automated monitoring of ukrainian power energy system objects to increase its operation safety
publisher National Technical University "Kharkiv Polytechnic Institute"
series Електротехніка і електромеханіка
issn 2074-272X
2309-3404
publishDate 2016-05-01
description The paper describes an algorithm of the complex automated monitoring of Ukraine’s power energy system, aimed at ensuring safety of its personnel and equipment. This monitoring involves usage of unmanned aerial vehicles (UAVs) for planned and unplanned registration status of power transmission lines (PTL) and high-voltage substations (HVS). It is assumed that unscheduled overflights will be made in emergency situations on power lines. With the help of the UAV, pictures of transmission and HVS will be recorded from the air in the optical and infrared ranges, as well as strength of electric (EF) and magnetic (MF) fields will be measured along the route of flight. Usage specially developed software allows to compare the recorded pictures with pre-UAV etalon patterns corresponding to normal operation of investigated transmission lines and the HVSs. Such reference pattern together with the experimentally obtained maps of HVS’s protective grounding will be summarized in a single document – a passport of HVS and PTL. This passport must also contain the measured and calculated values of strength levels of EF and MF in the places where staff of power facilities stay as well as layout of equipment, the most vulnerable to the effects of electromagnetic interference. If necessary, as part of ongoing monitoring, recommendations will be given on the design and location of electromagnetic screens, reducing the levels of electromagnetic interference as well as on location of lightning rods, reducing probability lightning attachment to the objects. The paper presents analytic expressions, which formed the basis of the developed software for calculation of the EF strength in the vicinity of power lines. This software will be used as a base at UAV navigation along the transmission lines, as well as to detect violations in the transmission lines operation. Comparison of distributions of EF strength calculated with the help of the elaborated software with the known literature data has been presented also. The difference between the proposed method of monitoring and the existing methods is full automation of the complex control of a number of parameters characterizing the state of the external power grid facilities, as well as its basic electrical parameters. This will be possible due to usage of specially developed software for recognition of optical and infrared images, as well as pictures of lines of equal EF and MF strength
topic power line
electric and magnetic fields
automated monitoring
unmanned aerial vehicles
url http://eie.khpi.edu.ua/article/view/2074-272X.2016.2.12/64359
work_keys_str_mv AT yeisokol amethodofcomplexautomatedmonitoringofukrainianpowerenergysystemobjectstoincreaseitsoperationsafety
AT mmrezinkina amethodofcomplexautomatedmonitoringofukrainianpowerenergysystemobjectstoincreaseitsoperationsafety
AT oggryb amethodofcomplexautomatedmonitoringofukrainianpowerenergysystemobjectstoincreaseitsoperationsafety
AT vivasilchenko amethodofcomplexautomatedmonitoringofukrainianpowerenergysystemobjectstoincreaseitsoperationsafety
AT aazuev amethodofcomplexautomatedmonitoringofukrainianpowerenergysystemobjectstoincreaseitsoperationsafety
AT avbortnikov amethodofcomplexautomatedmonitoringofukrainianpowerenergysystemobjectstoincreaseitsoperationsafety
AT evsosina amethodofcomplexautomatedmonitoringofukrainianpowerenergysystemobjectstoincreaseitsoperationsafety
AT yeisokol methodofcomplexautomatedmonitoringofukrainianpowerenergysystemobjectstoincreaseitsoperationsafety
AT mmrezinkina methodofcomplexautomatedmonitoringofukrainianpowerenergysystemobjectstoincreaseitsoperationsafety
AT oggryb methodofcomplexautomatedmonitoringofukrainianpowerenergysystemobjectstoincreaseitsoperationsafety
AT vivasilchenko methodofcomplexautomatedmonitoringofukrainianpowerenergysystemobjectstoincreaseitsoperationsafety
AT aazuev methodofcomplexautomatedmonitoringofukrainianpowerenergysystemobjectstoincreaseitsoperationsafety
AT avbortnikov methodofcomplexautomatedmonitoringofukrainianpowerenergysystemobjectstoincreaseitsoperationsafety
AT evsosina methodofcomplexautomatedmonitoringofukrainianpowerenergysystemobjectstoincreaseitsoperationsafety
_version_ 1721335777939423232