CORROSION of BOILER TUBES in SOUTH BAGHDAD ELECTRIC STATION
The corrosion of low carbon steel boiler tubes in demi water had been investigated. The purpose of this investigation was to determine the change produced in corrosion behavior of the carbon steel as a result of the specific presence of chloride and copper ions in the water under different temperat...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
University of Baghdad/College of Engineering
2010-09-01
|
Series: | Iraqi Journal of Chemical and Petroleum Engineering |
Online Access: | http://ijcpe.uobaghdad.edu.iq/index.php/ijcpe/article/view/378 |
id |
doaj-1e014567e23e4e1b98520ba63ebea46b |
---|---|
record_format |
Article |
spelling |
doaj-1e014567e23e4e1b98520ba63ebea46b2020-11-25T01:12:55ZengUniversity of Baghdad/College of EngineeringIraqi Journal of Chemical and Petroleum Engineering1997-48842618-07072010-09-01113CORROSION of BOILER TUBES in SOUTH BAGHDAD ELECTRIC STATIONCecilia Kh. HaweelJanet Lazar The corrosion of low carbon steel boiler tubes in demi water had been investigated. The purpose of this investigation was to determine the change produced in corrosion behavior of the carbon steel as a result of the specific presence of chloride and copper ions in the water under different temperatures. For low carbon steel experiments, the temperature was taken in three levels (125, 175, and 215°C) under about 27 bar pressure and 1500 rpm in autoclave. Using weight loss technique, the corrosion rate ranges from (85 to 789 gmd) for low carbon steel boiler tubes. http://ijcpe.uobaghdad.edu.iq/index.php/ijcpe/article/view/378 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Cecilia Kh. Haweel Janet Lazar |
spellingShingle |
Cecilia Kh. Haweel Janet Lazar CORROSION of BOILER TUBES in SOUTH BAGHDAD ELECTRIC STATION Iraqi Journal of Chemical and Petroleum Engineering |
author_facet |
Cecilia Kh. Haweel Janet Lazar |
author_sort |
Cecilia Kh. Haweel |
title |
CORROSION of BOILER TUBES in SOUTH BAGHDAD ELECTRIC STATION |
title_short |
CORROSION of BOILER TUBES in SOUTH BAGHDAD ELECTRIC STATION |
title_full |
CORROSION of BOILER TUBES in SOUTH BAGHDAD ELECTRIC STATION |
title_fullStr |
CORROSION of BOILER TUBES in SOUTH BAGHDAD ELECTRIC STATION |
title_full_unstemmed |
CORROSION of BOILER TUBES in SOUTH BAGHDAD ELECTRIC STATION |
title_sort |
corrosion of boiler tubes in south baghdad electric station |
publisher |
University of Baghdad/College of Engineering |
series |
Iraqi Journal of Chemical and Petroleum Engineering |
issn |
1997-4884 2618-0707 |
publishDate |
2010-09-01 |
description |
The corrosion of low carbon steel boiler tubes in demi water had been investigated. The purpose of this investigation was to determine the change produced in corrosion behavior of the carbon steel as a result of the specific presence of chloride and copper ions in the water under different temperatures. For low carbon steel experiments, the temperature was taken in three levels (125, 175, and 215°C) under about 27 bar pressure and 1500 rpm in autoclave. Using weight loss technique, the corrosion rate ranges from (85 to 789 gmd) for low carbon steel boiler tubes.
|