Design and Development of Hand and Foot Contamination Monitor

A hand and foot contamination monitor is a health physics instrument to provide detection and measurement of beta-gamma contamination on the palm of each hand and on the bottom surface of both feet/shoes. There are four channels of detection for two hands and two feet. Four G-M detectors have been u...

Full description

Bibliographic Details
Main Authors: F. Akter, F. Hafiz, M.A.S. Haque, M. Hoq, M. Hasan
Format: Article
Language:English
Published: Center for Development of Nuclear Informatics, National Nuclear Energy Agency (BATAN) 2014-08-01
Series:Atom Indonesia
Subjects:
Online Access:http://aij.batan.go.id/index.php/aij/article/view/276
id doaj-1e12831b323f4927a8c3b515cb13d790
record_format Article
spelling doaj-1e12831b323f4927a8c3b515cb13d7902020-11-25T01:02:27ZengCenter for Development of Nuclear Informatics, National Nuclear Energy Agency (BATAN)Atom Indonesia0126-15682014-08-0140297104Design and Development of Hand and Foot Contamination MonitorF. Akter0F. Hafiz1M.A.S. Haque2M. Hoq3M. Hasan4Institute of Electronics, Atomic Energy Research Establishment, Postcode-1349, Savar, Dhaka, BangladeshInstitute of Electronics, Atomic Energy Research Establishment, Postcode-1349, Savar, Dhaka, BangladeshInstitute of Electronics, Atomic Energy Research Establishment, Postcode-1349, Savar, Dhaka, BangladeshInstitute of Electronics, Atomic Energy Research Establishment, Postcode-1349, Savar, Dhaka, BangladeshAtomic Energy Research Establishment, Postcode-1349, Savar, Dhaka, BangladeshA hand and foot contamination monitor is a health physics instrument to provide detection and measurement of beta-gamma contamination on the palm of each hand and on the bottom surface of both feet/shoes. There are four channels of detection for two hands and two feet. Four G-M detectors have been used in a single unit to cover the whole area of hand and feet. A regulated high voltage DC power supply (900 V) has been designed using the PIC12F675 microcontroller to operate the pancake Geiger-Müller detectors. The reading is displayed on a linearly scaled 0-100 Bq/cm2 analog panel meter. The monitor detects beta–gamma radiation emitted by radioactive materials, and if the detected value exceeds a preset level, the monitor sounds an alarm and displays a reading in the respective panel meter. Indicator lamps are used to show the status of contamination. The performance of the system has been tested by using pulse generator and by flat surface radioactive calibration sources. Electronic linearity, detection efficiency, response to the contamination, calibration factor and percentage of error has been measured. Test results were satisfactory and the present system can be used instead of similar imported instruments.http://aij.batan.go.id/index.php/aij/article/view/276ContaminationG-M detectorMicrocontrollerPIC12F675
collection DOAJ
language English
format Article
sources DOAJ
author F. Akter
F. Hafiz
M.A.S. Haque
M. Hoq
M. Hasan
spellingShingle F. Akter
F. Hafiz
M.A.S. Haque
M. Hoq
M. Hasan
Design and Development of Hand and Foot Contamination Monitor
Atom Indonesia
Contamination
G-M detector
Microcontroller
PIC12F675
author_facet F. Akter
F. Hafiz
M.A.S. Haque
M. Hoq
M. Hasan
author_sort F. Akter
title Design and Development of Hand and Foot Contamination Monitor
title_short Design and Development of Hand and Foot Contamination Monitor
title_full Design and Development of Hand and Foot Contamination Monitor
title_fullStr Design and Development of Hand and Foot Contamination Monitor
title_full_unstemmed Design and Development of Hand and Foot Contamination Monitor
title_sort design and development of hand and foot contamination monitor
publisher Center for Development of Nuclear Informatics, National Nuclear Energy Agency (BATAN)
series Atom Indonesia
issn 0126-1568
publishDate 2014-08-01
description A hand and foot contamination monitor is a health physics instrument to provide detection and measurement of beta-gamma contamination on the palm of each hand and on the bottom surface of both feet/shoes. There are four channels of detection for two hands and two feet. Four G-M detectors have been used in a single unit to cover the whole area of hand and feet. A regulated high voltage DC power supply (900 V) has been designed using the PIC12F675 microcontroller to operate the pancake Geiger-Müller detectors. The reading is displayed on a linearly scaled 0-100 Bq/cm2 analog panel meter. The monitor detects beta–gamma radiation emitted by radioactive materials, and if the detected value exceeds a preset level, the monitor sounds an alarm and displays a reading in the respective panel meter. Indicator lamps are used to show the status of contamination. The performance of the system has been tested by using pulse generator and by flat surface radioactive calibration sources. Electronic linearity, detection efficiency, response to the contamination, calibration factor and percentage of error has been measured. Test results were satisfactory and the present system can be used instead of similar imported instruments.
topic Contamination
G-M detector
Microcontroller
PIC12F675
url http://aij.batan.go.id/index.php/aij/article/view/276
work_keys_str_mv AT fakter designanddevelopmentofhandandfootcontaminationmonitor
AT fhafiz designanddevelopmentofhandandfootcontaminationmonitor
AT mashaque designanddevelopmentofhandandfootcontaminationmonitor
AT mhoq designanddevelopmentofhandandfootcontaminationmonitor
AT mhasan designanddevelopmentofhandandfootcontaminationmonitor
_version_ 1725204865037107200