Summary: | The present study investigated the occurrence of selected micropollutants including emerging contaminants (mainly pharmaceuticals and personal care products- PPCPs) in selected water samples from swimming pool systems. The study area was selected based on the lack of available information regarding the suspected contamination of swimming pools water by PPCPs. The variety and concentration of chemical compounds in these aquatic systems can be quite diversified, presenting a challenge in terms of both purification and quality control. Determination of PPCPs requires very sensitive analytical methods that make it possible to confirm the presence of tested compounds in a complex organic extract. In this field, GC-MS gas chromatography can be used. This system enables to perform Selected Ion Monitoring, which reduces the detection limits of the investigated analyte. This paper aims at presentation of analytical methods and strategies adapted to obtain information on the composition and characteristics of water in swimming pool systems. The sample preparation methodology including solid phase extraction was developed for swimming pool water.
|