Efficacy of conventional and digital radiographic imaging methods for diagnosis of simulated external root resorption Eficácia dos métodos radiográficos convencional e digital no diagnóstico de reabsorções radiculares simuladas

This in vitro study evaluated and compared the efficacy of conventional (Kodak F-speed (Insight), Kodak) and a digital (DRS Gnatus System, Gnatus) radiographic imaging for diagnosis of simulated external root resorption cavities. Human mandibles containing teeth were covered with bovine muscle slice...

Full description

Bibliographic Details
Main Authors: Vânia Portela Ditzel Westphalen, Ivaldo Gomes de Moraes, Fernando Henrique Westphalen
Format: Article
Language:English
Published: University of São Paulo 2004-06-01
Series:Journal of Applied Oral Science
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572004000200005
id doaj-1f1cbd0f1f3f430e8d9780684750cef9
record_format Article
spelling doaj-1f1cbd0f1f3f430e8d9780684750cef92020-11-24T22:12:49ZengUniversity of São PauloJournal of Applied Oral Science1678-77571678-77652004-06-0112210811210.1590/S1678-77572004000200005Efficacy of conventional and digital radiographic imaging methods for diagnosis of simulated external root resorption Eficácia dos métodos radiográficos convencional e digital no diagnóstico de reabsorções radiculares simuladasVânia Portela Ditzel WestphalenIvaldo Gomes de MoraesFernando Henrique WestphalenThis in vitro study evaluated and compared the efficacy of conventional (Kodak F-speed (Insight), Kodak) and a digital (DRS Gnatus System, Gnatus) radiographic imaging for diagnosis of simulated external root resorption cavities. Human mandibles containing teeth were covered with bovine muscle slices in order to simulate the soft tissues. Nine teeth out of each group of teeth were investigated. Initially, three periapical radiographs of each tooth were taken using a tube shift technique with mesial and distal angulations in both methods. All teeth were subsequently extracted and had 0.7 and 1.0-mm deep cavities prepared on their buccal, mesial and distal surfaces at the cervical, middle and apical thirds. Steel cylinder burs (DORMER® - HSS) with 0.7 and 1.0-mm diameter were used. Each tooth was replaced on its socket and new radiographs were taken. Three examiners, an endodontist (1), a radiologist (2) and a general dentist (3), evaluated the images. Results were compared by z-test and showed a higher number of cavities detected by the digital method compared to the conventional, regardless of the deepness of the cavity. In decreasing order, examiners 2, 3 and 1 exhibited different potentials of detection of cavities with the conventional method. Examiners 1 and 3 exhibited superior potential than examiner 2 for detection of cavities of different sizes with the digital method.<br>O presente estudo visou avaliar e comparar, in vitro, a eficácia dos métodos radiográficos convencional (filmes de grupos de sensibilidade E/F Kodak Insight) e digital (Sistema Gnatus DRS), no diagnóstico de cavidades simulando reabsorções radiculares externas, em dentes contidos em mandíbulas humanas secas com músculo bovino simulando o tecido mole. As variáveis consideradas foram: tamanhos das cavidades e examinadores envolvidos. Foram utilizadas nove unidades de cada grupo dentário, incisivos (central e lateral), caninos, pré-molares e molares, sem lesões periapicais, as quais foram radiografadas inicialmente, em três tomadas radiográficas periapicais (orto, mesio e distorradial) pelos métodos radiográficos convencional e digital. Extraíram-se os dentes com o auxílio de fórceps e as cavidades de reabsorção foram confeccionadas com brocas cilíndricas DORMER® - HSS - Aço rápido, de 0,7 e 1,0 mm de diâmetro, nas profundidades 0,7 e 1,0 mm, para simular cavidades pequenas e médias, respectivamente, distribuídas nos terços radiculares cervical, médio e apical e nas faces vestibular, mesial e distal. Após a realização das cavidades os dentes eram reposicionados nos alvéolos e então, radiografados novamente pelos métodos convencional e digital, sendo esses passos comuns a ambos os diâmetros e profundidades das cavidades. As radiografias convencionais e digitais foram avaliadas por três cirurgiões-dentistas, sendo um radiologista, um endodontista e um clínico geral. Os resultados da investigação mostraram que, pelo método radiográfico digital o número de cavidades observadas foi maior do que pelo convencional, tanto para as cavidades pequenas (p<0,05), quanto para as médias (p<0,05).http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572004000200005Reabsorção radicular externaRadiografia digital diretaRadiografia dentáriaExternal root resorptionDirect digital radiographyDental radiography
collection DOAJ
language English
format Article
sources DOAJ
author Vânia Portela Ditzel Westphalen
Ivaldo Gomes de Moraes
Fernando Henrique Westphalen
spellingShingle Vânia Portela Ditzel Westphalen
Ivaldo Gomes de Moraes
Fernando Henrique Westphalen
Efficacy of conventional and digital radiographic imaging methods for diagnosis of simulated external root resorption Eficácia dos métodos radiográficos convencional e digital no diagnóstico de reabsorções radiculares simuladas
Journal of Applied Oral Science
Reabsorção radicular externa
Radiografia digital direta
Radiografia dentária
External root resorption
Direct digital radiography
Dental radiography
author_facet Vânia Portela Ditzel Westphalen
Ivaldo Gomes de Moraes
Fernando Henrique Westphalen
author_sort Vânia Portela Ditzel Westphalen
title Efficacy of conventional and digital radiographic imaging methods for diagnosis of simulated external root resorption Eficácia dos métodos radiográficos convencional e digital no diagnóstico de reabsorções radiculares simuladas
title_short Efficacy of conventional and digital radiographic imaging methods for diagnosis of simulated external root resorption Eficácia dos métodos radiográficos convencional e digital no diagnóstico de reabsorções radiculares simuladas
title_full Efficacy of conventional and digital radiographic imaging methods for diagnosis of simulated external root resorption Eficácia dos métodos radiográficos convencional e digital no diagnóstico de reabsorções radiculares simuladas
title_fullStr Efficacy of conventional and digital radiographic imaging methods for diagnosis of simulated external root resorption Eficácia dos métodos radiográficos convencional e digital no diagnóstico de reabsorções radiculares simuladas
title_full_unstemmed Efficacy of conventional and digital radiographic imaging methods for diagnosis of simulated external root resorption Eficácia dos métodos radiográficos convencional e digital no diagnóstico de reabsorções radiculares simuladas
title_sort efficacy of conventional and digital radiographic imaging methods for diagnosis of simulated external root resorption eficácia dos métodos radiográficos convencional e digital no diagnóstico de reabsorções radiculares simuladas
publisher University of São Paulo
series Journal of Applied Oral Science
issn 1678-7757
1678-7765
publishDate 2004-06-01
description This in vitro study evaluated and compared the efficacy of conventional (Kodak F-speed (Insight), Kodak) and a digital (DRS Gnatus System, Gnatus) radiographic imaging for diagnosis of simulated external root resorption cavities. Human mandibles containing teeth were covered with bovine muscle slices in order to simulate the soft tissues. Nine teeth out of each group of teeth were investigated. Initially, three periapical radiographs of each tooth were taken using a tube shift technique with mesial and distal angulations in both methods. All teeth were subsequently extracted and had 0.7 and 1.0-mm deep cavities prepared on their buccal, mesial and distal surfaces at the cervical, middle and apical thirds. Steel cylinder burs (DORMER® - HSS) with 0.7 and 1.0-mm diameter were used. Each tooth was replaced on its socket and new radiographs were taken. Three examiners, an endodontist (1), a radiologist (2) and a general dentist (3), evaluated the images. Results were compared by z-test and showed a higher number of cavities detected by the digital method compared to the conventional, regardless of the deepness of the cavity. In decreasing order, examiners 2, 3 and 1 exhibited different potentials of detection of cavities with the conventional method. Examiners 1 and 3 exhibited superior potential than examiner 2 for detection of cavities of different sizes with the digital method.<br>O presente estudo visou avaliar e comparar, in vitro, a eficácia dos métodos radiográficos convencional (filmes de grupos de sensibilidade E/F Kodak Insight) e digital (Sistema Gnatus DRS), no diagnóstico de cavidades simulando reabsorções radiculares externas, em dentes contidos em mandíbulas humanas secas com músculo bovino simulando o tecido mole. As variáveis consideradas foram: tamanhos das cavidades e examinadores envolvidos. Foram utilizadas nove unidades de cada grupo dentário, incisivos (central e lateral), caninos, pré-molares e molares, sem lesões periapicais, as quais foram radiografadas inicialmente, em três tomadas radiográficas periapicais (orto, mesio e distorradial) pelos métodos radiográficos convencional e digital. Extraíram-se os dentes com o auxílio de fórceps e as cavidades de reabsorção foram confeccionadas com brocas cilíndricas DORMER® - HSS - Aço rápido, de 0,7 e 1,0 mm de diâmetro, nas profundidades 0,7 e 1,0 mm, para simular cavidades pequenas e médias, respectivamente, distribuídas nos terços radiculares cervical, médio e apical e nas faces vestibular, mesial e distal. Após a realização das cavidades os dentes eram reposicionados nos alvéolos e então, radiografados novamente pelos métodos convencional e digital, sendo esses passos comuns a ambos os diâmetros e profundidades das cavidades. As radiografias convencionais e digitais foram avaliadas por três cirurgiões-dentistas, sendo um radiologista, um endodontista e um clínico geral. Os resultados da investigação mostraram que, pelo método radiográfico digital o número de cavidades observadas foi maior do que pelo convencional, tanto para as cavidades pequenas (p<0,05), quanto para as médias (p<0,05).
topic Reabsorção radicular externa
Radiografia digital direta
Radiografia dentária
External root resorption
Direct digital radiography
Dental radiography
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572004000200005
work_keys_str_mv AT vaniaporteladitzelwestphalen efficacyofconventionalanddigitalradiographicimagingmethodsfordiagnosisofsimulatedexternalrootresorptioneficaciadosmetodosradiograficosconvencionaledigitalnodiagnosticodereabsorcoesradicularessimuladas
AT ivaldogomesdemoraes efficacyofconventionalanddigitalradiographicimagingmethodsfordiagnosisofsimulatedexternalrootresorptioneficaciadosmetodosradiograficosconvencionaledigitalnodiagnosticodereabsorcoesradicularessimuladas
AT fernandohenriquewestphalen efficacyofconventionalanddigitalradiographicimagingmethodsfordiagnosisofsimulatedexternalrootresorptioneficaciadosmetodosradiograficosconvencionaledigitalnodiagnosticodereabsorcoesradicularessimuladas
_version_ 1725802283595202560