A Three-Phase Transformerless T-Type- NPC-MLI for Grid Connected PV Systems with Common-Mode Leakage Current Mitigation

DC to AC inverters are the well-known and improved in various kinds photovoltaic (PV) and gird tied systems. However, these inverters are require interfacing transformers to be synchronized with the grid-connected system. Therefore, the system is bulky and not economy. The transformerless inverter (...

Full description

Bibliographic Details
Main Authors: P. Madasamy, V. Suresh Kumar, P. Sanjeevikumar, Jens Bo Holm-Nielsen, Eklas Hosain, C. Bharatiraja
Format: Article
Language:English
Published: MDPI AG 2019-06-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/12/12/2434
id doaj-20a7a4d55f52455593144b6e62b83346
record_format Article
spelling doaj-20a7a4d55f52455593144b6e62b833462020-11-24T23:55:37ZengMDPI AGEnergies1996-10732019-06-011212243410.3390/en12122434en12122434A Three-Phase Transformerless T-Type- NPC-MLI for Grid Connected PV Systems with Common-Mode Leakage Current MitigationP. Madasamy0V. Suresh Kumar1P. Sanjeevikumar2Jens Bo Holm-Nielsen3Eklas Hosain4C. Bharatiraja5Department of Electrical and Electronics Engineering, Alagappa Chettiar college of Engineering and Technology, Karaikudi 630 003, Tamilnadu, IndiaDepartment of Electrical and Electronics Engineering, Thiagarajar College of Engineering, Madurai 625 015, Tamilnadu, IndiaCenter for Bioenergy and Green Engineering, Department of Energy Technology, Aalborg University, 6700 Esbjerg, DenmarkCenter for Bioenergy and Green Engineering, Department of Energy Technology, Aalborg University, 6700 Esbjerg, DenmarkOregon Renewable Energy Center (OREC), Department of Electrical Engineering & Renewable Energy, Oregon Tech, Klamath Falls, OR 97601, USADepartment of Electrical and Electronics Engineering, SRM University, Chennai 603 203, Tamilnadu, IndiaDC to AC inverters are the well-known and improved in various kinds photovoltaic (PV) and gird tied systems. However, these inverters are require interfacing transformers to be synchronized with the grid-connected system. Therefore, the system is bulky and not economy. The transformerless inverter (TLI) topologies and its grid interface techniques are increasingly engrossed for the benefit of high efficiency, reliability, and low cost. The main concern in the TL inverters is common mode voltage (CMV), which causes the switching-frequency leakage current, grid interface concerns and exaggerates the EMI problems. The single-phase inverter two-level topologies are well developed with additional switches and components for eliminating the CMV. Multilevel inverters (MLIs) based grid connected transformerless inverter topology is being researched to avail additional benefits from MLI, even through that are trust topologies presented in the literature. With the above aim, this paper has proposed three -phase three-level T type NP-MLI (TNP-MLI) topology with transformerless PV grid connected proficiency. The CM leakage current should handle over mitigating CMV through removing unwanted switching events in the inverter pulse width modulation (PWM). This paper is proposes PV connected T type NP-MLI interface with three-phase grid connected system with the help of improved space vector modulation (SVM) technique to mitigate the CM leakage current to overcome the above said requests on the PV tied TL grid connected system. This proposed the SVM technique to mitigate the CM leakage current by selecting only mediums, and zero vectors with suitable current control method in order to maintain the inverter current and grid interface requirements. The proposed PV tied TNP-MLI offering higher efficiency, lower breakdown voltage on the devices, smaller THD of output voltage, good reliability, and long life span. The paper also investigated the CM leakage currents envisage and behavior for the three-phase MLI through the inverter switching function, which is not discussed before. The proposed SVM on TL-TNP-MLI offers the reliable PV grid interface with very low switching-frequency leakage current (200mA) for all the PV and inverter operation conditions. The feasibility and effectiveness of the TLI and its control strategy is confirmed through the MATLAB/Simulink simulation model directly as compared with 2kW roof top PV plant connected TL-TNP-MLI experimentation, showing good accordance with theoretical investigation. The simulation and experimental results are demonstrated and presented in the good stability of steady state and dynamics performances. The proposed inverter reduces the cost of grid interface transformer, harmonics filter, and CMV suppressions choke.https://www.mdpi.com/1996-1073/12/12/2434Hybrid MicrogridBattery Electric VehicleEnergy management strategyVehicle-to-Vehicle ChargingEnergy Storage Unit
collection DOAJ
language English
format Article
sources DOAJ
author P. Madasamy
V. Suresh Kumar
P. Sanjeevikumar
Jens Bo Holm-Nielsen
Eklas Hosain
C. Bharatiraja
spellingShingle P. Madasamy
V. Suresh Kumar
P. Sanjeevikumar
Jens Bo Holm-Nielsen
Eklas Hosain
C. Bharatiraja
A Three-Phase Transformerless T-Type- NPC-MLI for Grid Connected PV Systems with Common-Mode Leakage Current Mitigation
Energies
Hybrid Microgrid
Battery Electric Vehicle
Energy management strategy
Vehicle-to-Vehicle Charging
Energy Storage Unit
author_facet P. Madasamy
V. Suresh Kumar
P. Sanjeevikumar
Jens Bo Holm-Nielsen
Eklas Hosain
C. Bharatiraja
author_sort P. Madasamy
title A Three-Phase Transformerless T-Type- NPC-MLI for Grid Connected PV Systems with Common-Mode Leakage Current Mitigation
title_short A Three-Phase Transformerless T-Type- NPC-MLI for Grid Connected PV Systems with Common-Mode Leakage Current Mitigation
title_full A Three-Phase Transformerless T-Type- NPC-MLI for Grid Connected PV Systems with Common-Mode Leakage Current Mitigation
title_fullStr A Three-Phase Transformerless T-Type- NPC-MLI for Grid Connected PV Systems with Common-Mode Leakage Current Mitigation
title_full_unstemmed A Three-Phase Transformerless T-Type- NPC-MLI for Grid Connected PV Systems with Common-Mode Leakage Current Mitigation
title_sort three-phase transformerless t-type- npc-mli for grid connected pv systems with common-mode leakage current mitigation
publisher MDPI AG
series Energies
issn 1996-1073
publishDate 2019-06-01
description DC to AC inverters are the well-known and improved in various kinds photovoltaic (PV) and gird tied systems. However, these inverters are require interfacing transformers to be synchronized with the grid-connected system. Therefore, the system is bulky and not economy. The transformerless inverter (TLI) topologies and its grid interface techniques are increasingly engrossed for the benefit of high efficiency, reliability, and low cost. The main concern in the TL inverters is common mode voltage (CMV), which causes the switching-frequency leakage current, grid interface concerns and exaggerates the EMI problems. The single-phase inverter two-level topologies are well developed with additional switches and components for eliminating the CMV. Multilevel inverters (MLIs) based grid connected transformerless inverter topology is being researched to avail additional benefits from MLI, even through that are trust topologies presented in the literature. With the above aim, this paper has proposed three -phase three-level T type NP-MLI (TNP-MLI) topology with transformerless PV grid connected proficiency. The CM leakage current should handle over mitigating CMV through removing unwanted switching events in the inverter pulse width modulation (PWM). This paper is proposes PV connected T type NP-MLI interface with three-phase grid connected system with the help of improved space vector modulation (SVM) technique to mitigate the CM leakage current to overcome the above said requests on the PV tied TL grid connected system. This proposed the SVM technique to mitigate the CM leakage current by selecting only mediums, and zero vectors with suitable current control method in order to maintain the inverter current and grid interface requirements. The proposed PV tied TNP-MLI offering higher efficiency, lower breakdown voltage on the devices, smaller THD of output voltage, good reliability, and long life span. The paper also investigated the CM leakage currents envisage and behavior for the three-phase MLI through the inverter switching function, which is not discussed before. The proposed SVM on TL-TNP-MLI offers the reliable PV grid interface with very low switching-frequency leakage current (200mA) for all the PV and inverter operation conditions. The feasibility and effectiveness of the TLI and its control strategy is confirmed through the MATLAB/Simulink simulation model directly as compared with 2kW roof top PV plant connected TL-TNP-MLI experimentation, showing good accordance with theoretical investigation. The simulation and experimental results are demonstrated and presented in the good stability of steady state and dynamics performances. The proposed inverter reduces the cost of grid interface transformer, harmonics filter, and CMV suppressions choke.
topic Hybrid Microgrid
Battery Electric Vehicle
Energy management strategy
Vehicle-to-Vehicle Charging
Energy Storage Unit
url https://www.mdpi.com/1996-1073/12/12/2434
work_keys_str_mv AT pmadasamy athreephasetransformerlessttypenpcmliforgridconnectedpvsystemswithcommonmodeleakagecurrentmitigation
AT vsureshkumar athreephasetransformerlessttypenpcmliforgridconnectedpvsystemswithcommonmodeleakagecurrentmitigation
AT psanjeevikumar athreephasetransformerlessttypenpcmliforgridconnectedpvsystemswithcommonmodeleakagecurrentmitigation
AT jensboholmnielsen athreephasetransformerlessttypenpcmliforgridconnectedpvsystemswithcommonmodeleakagecurrentmitigation
AT eklashosain athreephasetransformerlessttypenpcmliforgridconnectedpvsystemswithcommonmodeleakagecurrentmitigation
AT cbharatiraja athreephasetransformerlessttypenpcmliforgridconnectedpvsystemswithcommonmodeleakagecurrentmitigation
AT pmadasamy threephasetransformerlessttypenpcmliforgridconnectedpvsystemswithcommonmodeleakagecurrentmitigation
AT vsureshkumar threephasetransformerlessttypenpcmliforgridconnectedpvsystemswithcommonmodeleakagecurrentmitigation
AT psanjeevikumar threephasetransformerlessttypenpcmliforgridconnectedpvsystemswithcommonmodeleakagecurrentmitigation
AT jensboholmnielsen threephasetransformerlessttypenpcmliforgridconnectedpvsystemswithcommonmodeleakagecurrentmitigation
AT eklashosain threephasetransformerlessttypenpcmliforgridconnectedpvsystemswithcommonmodeleakagecurrentmitigation
AT cbharatiraja threephasetransformerlessttypenpcmliforgridconnectedpvsystemswithcommonmodeleakagecurrentmitigation
_version_ 1725461478210797568