Same Day Sputum Microscopy for Screening of Pulmonary Tuberculosis: its Accuracy and Usefulness in Comparison with Conventional Method

Sputum microscopy is the primary diagnostic tool for screening pulmonary tuberculosis (PTB) suspects in TB prevalent countries. Our study had evaluated the ‘front loading’ or ‘same day’ sputum microscopy feasibility to screen clinically suspected PTB cases, in comparison to standard method of sme...

Full description

Bibliographic Details
Main Authors: Druti Hazra, Vishnu Prasad Shenoy, Kiran Chawla
Format: Article
Language:English
Published: Journal of Pure and Applied Microbiology 2019-06-01
Series:Journal of Pure and Applied Microbiology
Subjects:
Online Access:https://microbiologyjournal.org/same-day-sputum-microscopy-for-screening-of-pulmonary-tuberculosis-its-accuracy-and-usefulness-in-comparison-with-conventional-method/
id doaj-21cf753120e84da98549f03ea0ae2cb2
record_format Article
spelling doaj-21cf753120e84da98549f03ea0ae2cb22021-10-02T18:52:35ZengJournal of Pure and Applied MicrobiologyJournal of Pure and Applied Microbiology0973-75102581-690X2019-06-011321251125610.22207/JPAM.13.2.67Same Day Sputum Microscopy for Screening of Pulmonary Tuberculosis: its Accuracy and Usefulness in Comparison with Conventional MethodDruti Hazra0Vishnu Prasad Shenoy1Kiran Chawla2Department of Microbiology, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal - 576 104, India.Department of Microbiology, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal - 576 104, India.Department of Microbiology, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal - 576 104, India.Sputum microscopy is the primary diagnostic tool for screening pulmonary tuberculosis (PTB) suspects in TB prevalent countries. Our study had evaluated the ‘front loading’ or ‘same day’ sputum microscopy feasibility to screen clinically suspected PTB cases, in comparison to standard method of smear microscopy. In this hospital based cross-sectional study, three sputum specimens i.e., two consecutive spot samples collected in one hour interval on the first day of visit and a single sputum sample was collected on the next day early morning from 312 randomly selected adults suspected for PTB. Sputum samples were cultured on Lowenstein-Jensen (LJ) medium and stained by auramine O method and examined under LED-fluorescence microscopy. Out of 312 presumptive PTB patients, 43 (13.8%) were smear-positive by front loading method and 46 (14.7%) by standard method respectively. Considering LJ media culture as the gold standard test, the sensitivity was 83.7% and 89.8% respectively for front loading and the standard sputum microscopy and specificity was 99.2% by both methods. The statistical difference was insignificant between two methods of sputum microscopy (p-value > 0.05 by McNemar’s test). In health care settings of high burden countries same day sputum microscopy could be an acceptable method to screen the suspects of pulmonary tuberculosis and complete the diagnosis procedure on the first day of visit, which will decrease patients’ drop-out from the diagnostic procedure and initiate treatments as soon as possible. https://microbiologyjournal.org/same-day-sputum-microscopy-for-screening-of-pulmonary-tuberculosis-its-accuracy-and-usefulness-in-comparison-with-conventional-method/front-loadingled fluorescence microscopypulmonary tuberculosissputum smeardiagnosissame day
collection DOAJ
language English
format Article
sources DOAJ
author Druti Hazra
Vishnu Prasad Shenoy
Kiran Chawla
spellingShingle Druti Hazra
Vishnu Prasad Shenoy
Kiran Chawla
Same Day Sputum Microscopy for Screening of Pulmonary Tuberculosis: its Accuracy and Usefulness in Comparison with Conventional Method
Journal of Pure and Applied Microbiology
front-loading
led fluorescence microscopy
pulmonary tuberculosis
sputum smear
diagnosis
same day
author_facet Druti Hazra
Vishnu Prasad Shenoy
Kiran Chawla
author_sort Druti Hazra
title Same Day Sputum Microscopy for Screening of Pulmonary Tuberculosis: its Accuracy and Usefulness in Comparison with Conventional Method
title_short Same Day Sputum Microscopy for Screening of Pulmonary Tuberculosis: its Accuracy and Usefulness in Comparison with Conventional Method
title_full Same Day Sputum Microscopy for Screening of Pulmonary Tuberculosis: its Accuracy and Usefulness in Comparison with Conventional Method
title_fullStr Same Day Sputum Microscopy for Screening of Pulmonary Tuberculosis: its Accuracy and Usefulness in Comparison with Conventional Method
title_full_unstemmed Same Day Sputum Microscopy for Screening of Pulmonary Tuberculosis: its Accuracy and Usefulness in Comparison with Conventional Method
title_sort same day sputum microscopy for screening of pulmonary tuberculosis: its accuracy and usefulness in comparison with conventional method
publisher Journal of Pure and Applied Microbiology
series Journal of Pure and Applied Microbiology
issn 0973-7510
2581-690X
publishDate 2019-06-01
description Sputum microscopy is the primary diagnostic tool for screening pulmonary tuberculosis (PTB) suspects in TB prevalent countries. Our study had evaluated the ‘front loading’ or ‘same day’ sputum microscopy feasibility to screen clinically suspected PTB cases, in comparison to standard method of smear microscopy. In this hospital based cross-sectional study, three sputum specimens i.e., two consecutive spot samples collected in one hour interval on the first day of visit and a single sputum sample was collected on the next day early morning from 312 randomly selected adults suspected for PTB. Sputum samples were cultured on Lowenstein-Jensen (LJ) medium and stained by auramine O method and examined under LED-fluorescence microscopy. Out of 312 presumptive PTB patients, 43 (13.8%) were smear-positive by front loading method and 46 (14.7%) by standard method respectively. Considering LJ media culture as the gold standard test, the sensitivity was 83.7% and 89.8% respectively for front loading and the standard sputum microscopy and specificity was 99.2% by both methods. The statistical difference was insignificant between two methods of sputum microscopy (p-value > 0.05 by McNemar’s test). In health care settings of high burden countries same day sputum microscopy could be an acceptable method to screen the suspects of pulmonary tuberculosis and complete the diagnosis procedure on the first day of visit, which will decrease patients’ drop-out from the diagnostic procedure and initiate treatments as soon as possible.
topic front-loading
led fluorescence microscopy
pulmonary tuberculosis
sputum smear
diagnosis
same day
url https://microbiologyjournal.org/same-day-sputum-microscopy-for-screening-of-pulmonary-tuberculosis-its-accuracy-and-usefulness-in-comparison-with-conventional-method/
work_keys_str_mv AT drutihazra samedaysputummicroscopyforscreeningofpulmonarytuberculosisitsaccuracyandusefulnessincomparisonwithconventionalmethod
AT vishnuprasadshenoy samedaysputummicroscopyforscreeningofpulmonarytuberculosisitsaccuracyandusefulnessincomparisonwithconventionalmethod
AT kiranchawla samedaysputummicroscopyforscreeningofpulmonarytuberculosisitsaccuracyandusefulnessincomparisonwithconventionalmethod
_version_ 1716848628158431232